Feasibility and sensitivity study of helical tomotherapy for dose painting plans

被引:41
作者
Deveau, Michael A. [1 ]
Bowen, Stephen R.
Westerly, David C. [2 ]
Jeraj, Robert [3 ,4 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Wisconsin Inst Med Res, Sch Med & Publ Hlth, Madison, WI 53705 USA
[2] Univ Colorado, Aurora, CO USA
[3] Univ Wisconsin, Dept Human Oncol, Sch Med & Publ Hlth, Ctr Clin Sci, Madison, WI USA
[4] Jozef Stefan Inst, Ljubljana 1000, Slovenia
关键词
INTENSITY-MODULATED RADIOTHERAPY; POSITRON-EMISSION-TOMOGRAPHY; IMRT; HEAD; ESCALATION; TUMOR;
D O I
10.3109/0284186X.2010.500302
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Important limitations for dose painting are due to treatment planning and delivery constraints. The purpose of this study was to develop a methodology for creating voxel-based dose painting plans that are deliverable using the clinical Tomo-Therapy Hi-Art II treatment planning system (TPS). Material and methods. Uptake data from a head and neck patient who underwent a [Cu-61]Cu-ATSM (hypoxia surrogate) PET/CT scan was retrospectively extracted for planning. Non-uniform voxel-based prescriptions were converted to structured-based prescriptions for compatibility with the Hi-Art II TPS. Optimized plans were generated by varying parameters such as dose level, structure importance, prescription point normalization, DVH volume, min/max dose, and dose penalty. Delivery parameters such as pitch, jaw width and modulation factor were also varied. Isodose distributions, quality volume histograms and planning target volume percentage receiving planned dose within 5% of the prescription (Q(0.95-1.05)) were used to evaluate plan conformity. Results. In general, the conformity of treatment plans to dose prescriptions was found to be adequate for delivery of dose painting plans. The conformity was better as the dose levels increased from three to nine levels (Q(0.95-1.05): 69% to 93%), jaw decreased in width from 5.0cm to 1.05cm (Q(0.95-1.05): 81% to 93%), and modulation factor increased up to 2.0 (Q(0.95-1.05): 36% to 92%). The conformity was invariant to changes in pitch. Plan conformity decreased as the prescription DVH constraint (Q(0.95-1.05): 93% vs. 89%) or the normalization point (Q(0.95-1.05): 93% vs. 90%) deviated from the means. Conclusion. This investigation demonstrated the ability of the Hi-Art II TPS to create voxel-based dose painting plans. Results indicated that agreement in prescription dose and planned dose distributions for all plans were sensitive to physical delivery parameter changes in jaw width and modulation factors, but insensitive to changes in pitch. Tight constraints on target structures also resulted in decreased plan conformity while under a relaxed set of optimization parameters, plan conformity was increased.
引用
收藏
页码:991 / 996
页数:6
相关论文
共 17 条
  • [1] On biologically conformal boost dose optimization
    Alber, M
    Paulsen, F
    Eschmann, SM
    Machulla, HJ
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (02) : N31 - N35
  • [2] Theragnostic imaging for radiation oncology: dose-painting by numbers
    Bentzen, SM
    [J]. LANCET ONCOLOGY, 2005, 6 (02) : 112 - 117
  • [3] On the sensitivity of IMRT dose optimization to the mathematical form of a biological imaging-based prescription function
    Bowen, Stephen R.
    Flynn, Ryan T.
    Bentzen, Soren M.
    Jeraj, Robert
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (06) : 1483 - 1501
  • [4] Chao K.S., 2002, RAD ONCOLOGY MANAGEM, V2nd
  • [5] Patterns of failure in patients receiving definitive and postoperative IMRT for head-and-neck cancer
    Chao, KSC
    Ozyigit, G
    Tran, BN
    Cengiz, M
    Dempsey, JF
    Low, DA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 55 (02): : 312 - 321
  • [6] On the performances of different IMRT treatment planning systems for selected paediatric cases
    Fogliata, Antonella
    Nicolini, Giorgia
    Alber, Markus
    Asell, Mats
    Clivio, Alessandro
    Dobler, Barbara
    Larsson, Malin
    Lohr, Frank
    Lorenz, Friedlieb
    Muzik, Jan
    Polednik, Martin
    Vanetti, Eugenio
    Wolff, Dirk
    Wyttenbach, Rolf
    Cozzi, Luca
    [J]. RADIATION ONCOLOGY, 2007, 2 (1)
  • [7] Feasibility study of helical tomotherapy for total body or total marrow irradiation
    Hui, SK
    Kapatoes, J
    Fowler, J
    Henderson, D
    Olivera, G
    Manon, RR
    Gerbi, B
    Mackie, TR
    Welsh, JS
    [J]. MEDICAL PHYSICS, 2005, 32 (10) : 3214 - 3224
  • [8] The helical tomotherapy thread effect
    Kissick, MW
    Fenwick, J
    James, JA
    Jerai, R
    Kapatoes, JM
    Keller, H
    Mackie, TR
    Olivera, G
    Soisson, ET
    [J]. MEDICAL PHYSICS, 2005, 32 (05) : 1414 - 1423
  • [9] Simultaneous integrated boost intensity-modulated radiotherapy for locally advanced head-and-neck squamous cell carcinomas: II - Clinical results
    Lauve, A
    Morris, M
    Schmidt-Ullrich, R
    Wu, QW
    Mohan, R
    Abayomi, O
    Buck, D
    Holdford, D
    Dawson, K
    Dinardo, L
    Reiter, E
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02): : 374 - 387
  • [10] Towards multidimensional radiotherapy (MD-CRT): Biological imaging and biological conformality
    Ling, CC
    Humm, J
    Larson, S
    Amols, H
    Fuks, Z
    Leibel, S
    Koutcher, JA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (03): : 551 - 560