In vivo demonstration of magnetic guidewire steerability in a MRI system with additional gradient coils

被引:19
作者
Lalande, Viviane [1 ]
Gosselin, Frederick P. [2 ]
Vonthron, Manuel [1 ]
Conan, Benjamin [1 ]
Tremblay, Charles [1 ]
Beaudoin, Gilles [3 ]
Soulez, Gilles [3 ]
Martel, Sylvain [1 ]
机构
[1] Ecole Polytech Montreal, Dept Genie Informat & Genie Logiciel, NanoRobot Lab, Montreal, PQ H3T 1J4, Canada
[2] Ecole Polytech Montreal, Dept Genie Mecan, Montreal, PQ H3T 1J4, Canada
[3] CHUM Hop Notre Dame, Dept Radiol, Montreal, PQ H2L 4M1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
guidewire; MRI; steering; in vivo; magnetic; magnetic gradient; NAVIGATION; CATHETER;
D O I
10.1118/1.4906194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the ability to control the steering of a modified guidewire actuated by the magnetic force of a magnetic resonance imaging system with additional gradient coils for selective arterial catheterization in rabbits. Methods: Selective catheterizations of the right renal artery, left renal artery, superior mesenteric artery, and iliac artery were performed on two rabbits. A 3D magnetic force was applied onto a magnetic bead placed at the tip of a guidewire. The ability of the guidewire to advance in the aorta without entering the side branches when the magnetic force was not applied was also evaluated. Steering of the guidewire was combined with a dedicated tracking system and its position was registered on the 3D model of a magnetic resonance angiography (MRA). Results: The magnetic catheterization of the renal arteries was successful and showed reproducibility. Superior mesenteric artery and iliac artery showed that the catheterization was feasible. These two arteries were difficult to visualize on MRA, making catheterization and setting the direction of the force more difficult. There was no inadvertent catheterization of side vessels when the guidewire was advanced with magnetic steering despite the hook shape at the tip of the guidewire caused by the alignment of the bead anisotropy with the permanent magnetic field. Conclusions: This first evaluation of selective catheterization of aortic branches with a magnetic guidewire provided a successful steering in the less angled side branches and this modified guidewire was advanced in the aorta without inadvertent selective catheterization when manipulated without magnetic actuation. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:969 / 976
页数:8
相关论文
共 21 条
  • [1] Magnetic Resonance Navigation of a Bead Inside a Three-Bifurcation PMMA Phantom Using an Imaging Gradient Coil Insert
    Bigot, Alexandre
    Tremblay, Charles
    Soulez, Gilles
    Martel, Sylvain
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2014, 30 (03) : 719 - 727
  • [2] MR-guided intravascular interventions: Techniques and applications
    Bock, Michael
    Wacker, Frank K.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (02) : 326 - 338
  • [3] Neuroendovascular magnetic navigation: clinical experience in ten patients
    Dabus, Guilherme
    Gerstle, Ronald J.
    Cross, DeWitte T., III
    Derdeyn, Colin P.
    Moran, Christopher J.
    [J]. NEURORADIOLOGY, 2007, 49 (04) : 351 - 355
  • [4] In vivo MR-tracking based on magnetic signature selective excitation
    Felfoul, Ouajdi
    Mathieu, Jean-Baptiste
    Beaudoin, Gilles
    Martel, Sylvain
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (01) : 28 - 35
  • [5] Steerable catheters in minimally invasive vascular surgery
    Fu, Yili
    Liu, Hao
    Huang, Wentai
    Wang, Shuguo
    Liang, Zhaoguang
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (04) : 381 - 391
  • [6] Characterization of the deflections of a catheter steered using a magnetic resonance imaging system
    Gosselin, Frederick P.
    Lalande, Viviane
    Martel, Sylvain
    [J]. MEDICAL PHYSICS, 2011, 38 (09) : 4994 - 5002
  • [7] Haga Y., 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308), P181, DOI 10.1109/MEMSYS.2000.838513
  • [8] ICNIRP STATEMENT-GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 HZ TO 100 KHZ)
    不详
    [J]. HEALTH PHYSICS, 2010, 99 (06): : 818 - 836
  • [9] Lalande V., 2012, CONCEPTION CARACTERI
  • [10] Automatic navigation of an untethered device in the artery of a living animal using a conventional clinical magnetic resonance imaging system
    Martel, Sylvain
    Mathieu, Jean-Baptiste
    Felfoul, Ouajdi
    Chanu, Arnaud
    Aboussouan, Eric
    Tamaz, Samer
    Pouponneau, Pierre
    [J]. APPLIED PHYSICS LETTERS, 2007, 90 (11)