Modeling and simulation of a phase change material system for improving summer comfort in domestic residence

被引:68
作者
Borderon, Julien [1 ,3 ]
Virgone, Joseph [2 ]
Cantin, Richard [1 ]
机构
[1] Cerema, Reg Lab Strasbourg, Strasbourg, France
[2] Univ Lyon 1, CETHIL, UMR 5008, INSA Lyon, F-69622 Villeurbanne, France
[3] Univ Lyon, ENTPE, LGCB, Lyon, France
关键词
Phase Change Materials; Ventilation; Heat storage; Dynamic thermal simulation; Passive cooling; THERMAL-ENERGY STORAGE; AIR HEAT-EXCHANGER; VENTILATION SYSTEM; BUILDING WALLS; FULL-SCALE; PCM; VALIDATION; EFFICIENCY; WALLBOARD;
D O I
10.1016/j.apenergy.2014.11.062
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the current context of thermal improvement in the building sector, research of new solutions to integrate to the retrofitting process is an essential step in the way of saving energy. With the purpose of maintaining or improving the summer comfort after a retrofitting in a residential building, Phase Change Materials (PCM) could be used to bring enough inertia to use the freshness of night for cooling during the warmest hour in the day. Passive solutions of PCM integration have demonstrated their limited benefits. Using PCM in the way proposed in this article goes through the design of a PCM/air system able to store latent heat. This unit is coupled to the ventilation system to ensure that the heat transfers between the ventilated air and the PCM stock are forced convection and then higher than the ones with natural convection. The fusion and solidification temperature for the PCM needs to be carefully chosen to allow the latent heat storage. To analyze the behavior of such a system in a retrofitted house with the climate of 4 different French cities, simulations in different configurations have been carried out. According to these climates, we analyze the necessary conditions for the improvement of efficiency of PCM use. Also, the appropriate PCM melting temperature range is defined with corresponding existing PCM characteristics. After, optimal thickness is obtained considering the diurnal temperature evolutions. The TRNSYS software runs the modeled house, coupled with Matlab for the PCM/air system model. The number of units of such a system can be changed and adapted to the different climates. Results are expressed in terms of percentage of the time when the indoor operative temperature reaches a certain level. Comparisons are made with classical systems without PCM. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:288 / 296
页数:9
相关论文
共 29 条
  • [1] ADEME, 2007, CPM06314HSCP ADEME
  • [2] Building integration of PCM for natural cooling of buildings
    Alvarez, Servando
    Cabeza, Luisa F.
    Ruiz-Pardo, Alvaro
    Castell, Albert
    Tenorio, Jose Antonio
    [J]. APPLIED ENERGY, 2013, 109 : 514 - 522
  • [3] [Anonymous], 1978, ADV HEAT TRANSFER
  • [4] [Anonymous], TRNSYS 16 MANUAL
  • [5] [Anonymous], THESIS ENTPE LYON
  • [6] Free cooling of a building using PCM heat storage integrated into the ventilation system
    Arkar, C.
    Medved, S.
    [J]. SOLAR ENERGY, 2007, 81 (09) : 1078 - 1087
  • [7] Efficiency of free cooling using latent heat storage integrated into the ventilation system of a low energy building
    Arkar, C.
    Vidrih, B.
    Medved, S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 134 - 143
  • [8] Energy refurbishment of existing buildings through the use of phase change materials: Energy savings and indoor comfort in the cooling season
    Ascione, Fabrizio
    Bianco, Nicola
    De Masi, Rosa Francesca
    de' Rossi, Filippo
    Vanoli, Giuseppe Peter
    [J]. APPLIED ENERGY, 2014, 113 : 990 - 1007
  • [9] Phase change materials for building applications: A state-of-the-art review
    Baetens, Ruben
    Jelle, Bjorn Petter
    Gustavsen, Arild
    [J]. ENERGY AND BUILDINGS, 2010, 42 (09) : 1361 - 1368
  • [10] Full-scale study of a building equipped with a multi-layer rack latent heat thermal energy storage system
    Borderon, Julien
    Virgone, Joseph
    Cantin, Richard
    Kuznik, Frederic
    [J]. HVAC&R RESEARCH, 2011, 17 (04): : 566 - 576