A six-year retrospective analysis of cutout risk predictors in cephalomedullary nailing for pertrochanteric fractures

被引:64
作者
Caruso, G. [1 ]
Bonomo, M. [1 ]
Valpiani, G. [2 ,3 ]
Salvatori, G. [1 ]
Gildone, A. [2 ,4 ]
Lorusso, V. [2 ,4 ]
Massari, L. [1 ]
机构
[1] Univ Ferrara, Trauma & Orthopaed Surg, Dept Morphol Surg & Expt Med, Via Borsari 47, I-44121 Ferrara, FE, Italy
[2] Univ Ferrara, Ferrara, Italy
[3] Univ Ferrara Arcispedale St Anna, Azienda Osped, Res & Innovat Off, Via Aldo Moro 8, I-44124 Ferrara, FE, Italy
[4] Univ Ferrara Arcispedale St Anna, Azienda Osped, Orthopaed & Traumatol Dept, Via Aldo Moro 8, I-44124 Ferrara, FE, Italy
来源
BONE & JOINT RESEARCH | 2017年 / 6卷 / 08期
关键词
Pertrochanteric fractures; Cut-out; Tip-apex distance; Calcar-referenced tip-apex distance; TIP-APEX DISTANCE; SLIDING HIP SCREW; INTERTROCHANTERIC FRACTURES; TROCHANTERIC FRACTURES; FIXATION; FAILURE; POSITION;
D O I
10.1302/2046-3758.68.BJR-2016-0299.R1
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Objectives Intramedullary fixation is considered the most stable treatment for pertrochanteric fractures of the proximal femur and cut-out is one of the most frequent mechanical complications. In order to determine the role of clinical variables and radiological parameters in predicting the risk of this complication, we analysed the data pertaining to a group of patients recruited over the course of six years. Methods A total of 571 patients were included in this study, which analysed the incidence of cut-out in relation to several clinical variables: age; gender; the AO Foundation and Orthopaedic Trauma Association classification system (AO/OTA); type of nail; cervical-diaphyseal angle; surgical wait times; anti-osteoporotic medication; complete post-operative weight bearing; and radiological parameters (namely the lag-screw position with respect to the femoral head, the Cleveland system, the tip-apex distance (TAD), and the calcar-referenced tip-apex distance (CalTAD)). Results The incidence of cut-out across the sample was 5.6%, with a higher incidence in female patients. A significantly higher risk of this complication was correlated with lag-screw tip positioning in the upper part of the femoral head in the anteroposterior radiological view, posterior in the latero-lateral radiological view, and in the Cleveland peripheral zones. The tip-apex distance and the calcar-referenced tip-apex distance were found to be highly significant predictors of the risk of cut-out at cut-offs of 30.7 mm and 37.3 mm, respectively, but the former appeared more reliable than the latter in predicting the occurrence of this complication. Conclusion The tip-apex distance remains the most accurate predictor of cut-out, which is significantly greater above a cut-off of 30.7 mm.
引用
收藏
页码:481 / 488
页数:8
相关论文
共 27 条
[1]   Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures [J].
Andruszkow, Hagen ;
Frink, Michael ;
Froemke, Cornelia ;
Matityahu, Amir ;
Zeckey, Christian ;
Mommsen, Philipp ;
Suntardjo, Stefanie ;
Krettek, Christian ;
Hildebrand, Frank .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (11) :2347-2354
[2]   THE VALUE OF THE TIP-APEX DISTANCE IN PREDICTING FAILURE OF FIXATION OF PERITROCHANTERIC FRACTURES OF THE HIP [J].
BAUMGAERTNER, MR ;
CURTIN, SL ;
LINDSKOG, DM ;
KEGGI, JM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (07) :1058-1064
[3]   Awareness of tip-apex distance reduces failure of fixation of trochanteric fractures of the hip [J].
Baumgaertner, MR ;
Solberg, BD .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (06) :969-971
[4]   3066 consecutive Gamma Nails. 12 years experience at a single centre [J].
Bojan, Alicja J. ;
Beimel, Claudia ;
Speitling, Andreas ;
Taglang, Gilbert ;
Ekholm, Carl ;
Joensson, Anders .
BMC MUSCULOSKELETAL DISORDERS, 2010, 11
[5]   A 10-YEAR ANALYSIS OF INTERTROCHANTERIC FRACTURES OF THE FEMUR [J].
CLEVELAND, M ;
BOSWORTH, DM ;
THOMPSON, FR ;
WILSON, HJ ;
ISHIZUKA, T .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1959, 41 (08) :1399-1408
[6]   Reliability of Predictors for Screw Cutout in Intertrochanteric Hip Fractures [J].
De Bruijn, Kirstin ;
den Hartog, Dennis ;
Tuinebreijer, Wim ;
Roukema, Gert .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (14) :1266-1272
[7]   What Is the Relevance of the Tip-Apex Distance as a Predictor of Lag Screw Cut-Out? [J].
Goffin, Jerome M. ;
Jenkins, Paul J. ;
Ramaesh, Rishikesan ;
Pankaj, Pankaj ;
Simpson, A. Hamish .
PLOS ONE, 2013, 8 (08)
[8]   The importance of lag screw position for the stabilization of trochanteric fractures with a sliding hip screw: A subject-specific finite element study [J].
Goffin, Jerome M. ;
Pankaj, Pankaj ;
Simpson, A. Hamish .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2013, 31 (04) :596-600
[9]   HOW TO MINIMIZE FAILURES OF FIXATION OF UNSTABLE INTERTROCHANTERIC FRACTURES [J].
GUNDLE, R ;
GARGAN, MF ;
SIMPSON, AHRW .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1995, 26 (09) :611-614
[10]   Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients [J].
Hsueh, Kuang-Kai ;
Fang, Chi-Kuang ;
Chen, Chuan-Mu ;
Su, Yu-Ping ;
Wu, Heng-Fei ;
Chiu, Fang-Yao .
INTERNATIONAL ORTHOPAEDICS, 2010, 34 (08) :1273-1276