Metal-on-Metal Compared With Metal-on-Polyethylene: The Effect on Trunnion Corrosion in Total Hip Arthroplasty

被引:22
作者
Lanting, Brent A. [1 ]
Teeter, Matthew G. [2 ]
Howard, James L. [1 ]
MacDonald, Steven J. [1 ]
Van Citters, Douglas W. [3 ]
机构
[1] Univ Western Ontario, Div Orthopaed Surg, Dept Surg, London Hlth Sci Ctr, Univ Campus,339 Windermere Rd, London, ON N6A 5A5, Canada
[2] Univ Western Ontario, London Hlth Sci Ctr, Dept Surg, Univ Campus, London, ON, Canada
[3] Dartmouth Coll, Thayer Sch Engn, Dept Surg, Hanover, NH 03755 USA
关键词
trunnionosis; taperosis; total hip; corrosion; fretting; LARGE-DIAMETER METAL; HEAD-NECK TAPER; REPLACEMENTS; DESIGN; PSEUDOTUMOR; COMPONENTS; RETRIEVAL; INTERFACE; CHARNLEY; JUNCTION;
D O I
10.1016/j.arth.2017.03.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Trunnion tribocorrosion in total hip arthroplasties is concerning, but retrieval studies often are subjective or lack comparison groups. Quantitative comparisons of clinically relevant implants are required. The purpose of this investigation was to evaluate material loss in metal-on-metal (MoM) and metal-on-polyethylene (MoP) total hip articulations while controlling for trunnion design and head size. Methods: The 166 retrieved femoral heads from 2 manufacturers were analyzed. Four cohorts based on head size, trunnion design, manufacturer, and articulation type (MoM vs MoP) were created. Corrosion was measured by a coordinate measurement machine, and material loss was assessed (MATLAB). Results: Retrieved femoral heads from MoP articulations had 5 times less trunnion material loss than MoM articulations, on average, for both manufacturers. There was no difference in material loss between large modular head (>40 mm) and 36-mm MoM hip trunnion. Implants with a material loss above the detectable limit demonstrated a correlation with time in vivo only in MoP articulations. Conclusion: Retrieved femoral heads from MoP bearing couples had a lower magnitude of material loss than MoM couples, independent of head diameter. A time in vivo effect was only seen in MoP bearings. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:2574 / 2579
页数:6
相关论文
共 32 条
[1]   A Prospective Metal Ion Study of Large-Head Metal-on-Metal Bearing: A Matched-Pair Analysis of Hip Resurfacing Versus Total Hip Replacement [J].
Beaule, Paul E. ;
Kim, Paul R. ;
Hamdi, Amre ;
Fazekas, Anna .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) :251-+
[2]   Charnley total hip arthroplasty with cement - Minimum twenty-five-year follow-up [J].
Callaghan, JJ ;
Albright, JC ;
Goetz, DD ;
Olejniczak, JP ;
Johnston, RC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (04) :487-497
[3]   Wear particles from metal-on-metal total hip replacements: effects of implant design and implantation time [J].
Catelas, I ;
Campbell, PA ;
Bobyn, JD ;
Medley, JB ;
Huk, OL .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :195-208
[4]   Pseudotumour Formation Due to Tribocorrosion at the Taper Interface of Large Diameter Metal on Polymer Modular Total Hip Replacements [J].
Cook, Richard B. ;
Bolland, Benjamin J. R. F. ;
Wharton, Julian A. ;
Tilley, Simon ;
Latham, Jeremy M. ;
Wood, Robert J. K. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (08) :1430-1436
[5]   Corrosion at the Head-Neck Taper as a Cause for Adverse Local Tissue Reactions After Total Hip Arthroplasty [J].
Cooper, H. John ;
Della Valle, Craig J. ;
Berger, Richard A. ;
Tetreault, Matthew ;
Paprosky, Wayne G. ;
Sporer, Scott M. ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (18) :1655-1661
[6]   Taperosis DOES HEAD LENGTH AFFECT FRETTING AND CORROSION IN TOTAL HIP ARTHROPLASTY? [J].
Del Balso, C. ;
Teeter, M. G. ;
Tan, S. C. ;
Lanting, B. A. ;
Howard, J. L. .
BONE & JOINT JOURNAL, 2015, 97B (07) :911-916
[7]   Total hip arthroplasty head-neck contact mechanics: A stochastic investigation of key parameters [J].
Donaldson, Finn E. ;
Coburn, James C. ;
Siegel, Karen Lohmann .
JOURNAL OF BIOMECHANICS, 2014, 47 (07) :1634-1641
[8]   The Influence of Head Size on Corrosion and Fretting Behaviour at the Head-Neck Interface of Artificial Hip Joints [J].
Dyrkacz, Richard M. R. ;
Brandt, Jan-M. ;
Ojo, Olanrewaju A. ;
Turgeon, Thomas R. ;
Wyss, Urs P. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (06) :1036-1040
[9]   Stability and Trunnion Wear Potential in Large-diameter Metal-on-Metal Total Hips: A Finite Element Analysis [J].
Elkins, Jacob M. ;
Callaghan, John J. ;
Brown, Thomas D. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (02) :529-542
[10]   What is the Trouble With Trunnions? [J].
Esposito, Christina I. ;
Wright, Timothy M. ;
Goodman, Stuart B. ;
Berry, Daniel J. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2014, 472 (12) :3652-3658