Determination of Doped Concentrations in ICF Shells by X-Ray Equivalent Absorption

被引:5
作者
Wang, Zongwei [1 ]
Wang, Qi [1 ]
Ma, Xiaojun [1 ]
Gao, Dangzhong [1 ]
He, Xiaoshan [1 ]
Meng, Jie [1 ]
Jiang, Kai [1 ]
Hu, Yong [1 ]
Gu, Qianqian [1 ]
Chen, Xue [1 ]
Tong, Weichao [1 ]
Tang, Xing [1 ]
机构
[1] China Acad Engn Phys, Laser Fus Res Ctr, POB 919-987, Mianyang 621900, Sichuan, Peoples R China
关键词
Inertial confinement fusion; equivalent absorption; doped concentrations; RADIOGRAPHY; DOPANT;
D O I
10.1080/15361055.2017.1291045
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An X-ray equivalent absorption technique is developed to determine the doped concentrations of the inertial confinement fusion shells. Doped atoms in the shells are used to increase the opacity for radiation, to improve the absorptive capacity of the shell wall for X-ray, and to restrain the growth of hydromechanics instability. The doped concentrations in the shells are difficult to determine for the relatively thick shell wall and the spatial resolution. A novel model is proposed to determine the doped concentrations by a theory of X-ray equivalent absorption. The advantage of this model is that optical density (D) and the exposure curve [D = F(I)] of film plates are not necessary to calculate the doped concentrations. The model is validated with a thickness error of 2% by the polypropylene step wedge, the aluminum step wedge, and the polystyrene sphere. The error of results for doped concentration between this method and the energy-dispersive spectroscopy method is less than 0.1 at. %. The uncertainty also is analyzed and the combined expanded uncertainty is better than 0.2 at. % for the Ge-doped glow discharge polymer shell (k = 2).
引用
收藏
页码:69 / 75
页数:7
相关论文
共 8 条
  • [1] Algorithm for better x-radiography analyses
    Bernat, D
    Stephens, RB
    [J]. FUSION TECHNOLOGY, 1997, 31 (04): : 473 - 476
  • [2] Quantitative radiography: Film model calibration and dopant/impurity measurement in ICF ablators
    Huang, H.
    Stephens, R. B.
    Nikroo, A.
    Eddinger, S. A.
    Chen, K. C.
    Xu, H. W.
    Moreno, K. A.
    Youngblood, K. P.
    Skelton, M.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2007, 51 (04) : 530 - 538
  • [3] Nondestructive quantitative dopant profiling technique by contact radiography
    Huang, H.
    Stephens, R. B.
    Eddinger, S. A.
    Gunther, J.
    Nikroo, A.
    Chen, K. C.
    Xu, H. W.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2006, 49 (04) : 650 - 656
  • [4] ELEMENT-SPECIFIC PROFILING FOR ICF ABLATOR CAPSULES WITH MIXED DOPANT AND IMPURITIES
    Huang, H.
    Nikroo, A.
    Stephens, R. B.
    Eddinger, S. A.
    Wall, D. R.
    Moreno, K. A.
    Xu, H. W.
    [J]. FUSION SCIENCE AND TECHNOLOGY, 2009, 55 (04) : 356 - 366
  • [5] Quantitative characterization of inertial confinement fusion capsules using phase contrast enhanced x-ray imaging
    Kozioziemski, BJ
    Koch, JA
    Barty, A
    Martz, HE
    Lee, WK
    Fezzaa, K
    [J]. JOURNAL OF APPLIED PHYSICS, 2005, 97 (06)
  • [6] PRECISION SHELL CHARACTERIZATION USING RADIAL AVERAGING OF X-RAY IMAGES
    STEPHENS, RB
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1995, 13 (03): : 979 - 982
  • [7] Three-dimensional thickness reconstruction of ICF shells using X-ray tomography
    Wang, Zongwei
    Ma, Xiaojun
    Meng, Jie
    Wang, Qi
    Gao, Dangzhong
    [J]. FUSION ENGINEERING AND DESIGN, 2015, 100 : 525 - 530
  • [8] ZSCHORNACK G., 2007, HDB XRAY DATA, P735