Influence of Shielding Composition on Transmission Curves Determination for Diagnostic Radiology: a Monte Carlo Study Using the GEANT4 code

被引:1
|
作者
Hoff, Gabriela [1 ]
Firmino, Sandro F. [1 ]
da Souza, Wedla P. [1 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Fac Fis, BR-90619900 Porto Alegre, RS, Brazil
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
D O I
10.1109/NSSMIC.2009.5401654
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this work is to generate transmission curves to study the influence of material composition specificity of elemental composition its curves calculations. We used the Geant4 toolkit to generate the curves for primary broad beam geometry. The photon spectra used, on this work, were monoenergetic, from 60kV up to 150kV, and polienergetic, into the rage of 60kVp up to 150 kVp. The materials studied were barite concrete, barite mortar and steel for the energies applied on diagnostic radiology. The results of this work showed that the spectra applied to diagnostic radiology can be sensitive of shielding composition for the some conditions and all material studied As an example, considering monoenergetic beam showed higher variations of 25% for barite mortar when the larger shielding thicknesses were simulated.
引用
收藏
页码:540 / 543
页数:4
相关论文
共 50 条
  • [41] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Rahman, Ziaur
    Rehman, Shakeel Ur
    Arshed, Waheed
    Mirza, Nasir M.
    Rashid, Abdul
    Zeb, Jahan
    CHINESE PHYSICS C, 2012, 36 (11) : 1150 - 1156
  • [42] The Design of a Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder Using GEANT4 Monte Carlo Simulation Code
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E857 - E858
  • [43] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, 36 (11) : 1150 - 1156
  • [44] Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4
    Thiam, C.
    Bobin, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1515 - 1518
  • [45] Monte carlo simulation of the response to fast neutrons of a multi-gap RPC (MRPC) by using the GEANT4 code
    J. T. Rhee
    Hyun Yong Jo
    M. Jamil
    Y. J. Jeon
    Journal of the Korean Physical Society, 2012, 60 : 1023 - 1027
  • [46] Simulating Curves of Transmission Used on PetCT Applications, Using Geant4 Toolkit
    Hoff, Gabriela
    de Souza, Wedla Pires
    Brasil, Raquel B.
    Costa, Paulo Roberto
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1199 - 1202
  • [47] Re-engineering a nanodosimetry Monte Carlo code into Geant4: software design and first results
    Gargioni, E.
    Grichine, V.
    Pia, M. G.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2174 - +
  • [48] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [49] Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam
    Salama, E.
    Ali, A. S.
    Emad, N.
    Radi, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2015, 48 (02): : 70 - 76
  • [50] Energy Distributions of Particles Generated for Proton Interactions in Water: A Simulation with GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    MEDICAL PHYSICS, 2008, 35 (06)