Influence of Shielding Composition on Transmission Curves Determination for Diagnostic Radiology: a Monte Carlo Study Using the GEANT4 code

被引:1
|
作者
Hoff, Gabriela [1 ]
Firmino, Sandro F. [1 ]
da Souza, Wedla P. [1 ]
机构
[1] Pontificia Univ Catolica Rio Grande do Sul, Fac Fis, BR-90619900 Porto Alegre, RS, Brazil
来源
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2009年
关键词
D O I
10.1109/NSSMIC.2009.5401654
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this work is to generate transmission curves to study the influence of material composition specificity of elemental composition its curves calculations. We used the Geant4 toolkit to generate the curves for primary broad beam geometry. The photon spectra used, on this work, were monoenergetic, from 60kV up to 150kV, and polienergetic, into the rage of 60kVp up to 150 kVp. The materials studied were barite concrete, barite mortar and steel for the energies applied on diagnostic radiology. The results of this work showed that the spectra applied to diagnostic radiology can be sensitive of shielding composition for the some conditions and all material studied As an example, considering monoenergetic beam showed higher variations of 25% for barite mortar when the larger shielding thicknesses were simulated.
引用
收藏
页码:540 / 543
页数:4
相关论文
共 50 条
  • [1] Calculation of extrapolation curves in the 4π(LS)β-γ coincidence technique with the Monte Carlo code Geant4
    Bobin, C.
    Thiam, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2016, 109 : 319 - 324
  • [2] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [3] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    S. Kaddouch
    N. El Khayati
    Moscow University Physics Bulletin, 2017, 72 : 658 - 662
  • [4] Monte Carlo studies of the Tunisian gamma irradiation facility using GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    Mannai, K
    Trabelsi, A
    APPLIED RADIATION AND ISOTOPES, 2006, 64 (02) : 170 - 177
  • [5] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [6] SIMULATION OF THE NEUTRON SPECTRA EVOLUTION WITH GEANT4 MONTE CARLO CODE
    Smolyar, V. P.
    Mileva, A. O.
    Tarasov, V. O.
    Neboha, H. H.
    Rusov, V. D.
    JOURNAL OF PHYSICAL STUDIES, 2021, 25 (02):
  • [7] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [8] Geant4/GATE Monte Carlo Code for Internal Dosimetry Using Voxelized Phantom
    Kaddouch, S.
    El Khayati, N.
    MOSCOW UNIVERSITY PHYSICS BULLETIN, 2017, 72 (06) : 658 - 662
  • [9] Comparison Among Homogeneous Models and a Voxel Model on Mammography: a Monte Carlo Study Using the GEANT4 code
    Cassola, Vagner F.
    Hoff, Gabriela
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2428 - +
  • [10] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398