Au nanoparticle-polyaniline nanocomposite layers obtained through layer-by-layer adsorption for the simultaneous determination of dopamine and uric acid

被引:66
作者
Stoyanova, A. [1 ]
Ivanov, S. [1 ]
Tsakova, V. [1 ]
Bund, A. [2 ]
机构
[1] Bulgarian Acad Sci, Inst Phys Chem, BU-1113 Sofia, Bulgaria
[2] Tech Univ Dresden, Lehrstuhl Phys Chem & Elektrochem, D-01062 Dresden, Germany
关键词
Polyaniline; Au nanoparticles; Layer-by-layer adsorption; Dopamine; Uric acid; GLASSY-CARBON ELECTRODE; ASCORBIC-ACID; GOLD NANOPARTICLES; ELECTROCHEMICAL DETERMINATION; SELECTIVE DETERMINATION; MULTILAYER FILMS;
D O I
10.1016/j.electacta.2010.09.054
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The layer-by-layer adsorption technique was used to prepare polyaniline (PANI)-gold nanoparticles (AuNP) multilayered structures with different AuNP/PANI ratios. By means of microgravimetric measurements it was found that the amount of the adsorbed species depends on the duration of the AuNP adsorption step. At fixed adsorption step durations the amount of both (PANI and AuNP) materials increases linearly with the number of adsorption steps. Two types of PANI-AuNP multilayered nanocomposites with different AuNP/PANI ratio were studied as electrocatalytic materials for dopamine and uric acid oxidation. The sensitivity of PANI-AuNP for dopamine oxidation was found to depend on type of the nanocomposite whereas for uric acid oxidation the sensitivity remained unaffected by the type of the nanocomposite structure. This result is discussed in terms of the different limitations for both oxidation reactions. By means of differential pulse voltammetry experiments linear concentration dependences of the anodic peak currents were observed for both dopamine and uric acid in the concentration ranges 7-148 mu mol dm(-3) and 29-720 mu mol dm(-3), respectively. In the presence of both analytes no interference effects were detected. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3693 / 3699
页数:7
相关论文
共 50 条
  • [31] Fabrication of layer-by-layer deposited films containing carbon nanotubes and poly (malachite green) as a sensor for simultaneous determination of ascorbic acid, epinephrine, and uric acid
    Raoof, Jahan Bakhsh
    Ojani, Reza
    Baghayeri, Mehdi
    TURKISH JOURNAL OF CHEMISTRY, 2013, 37 (01) : 36 - 50
  • [32] Electrostatically mediated layer-by-layer assembly of nitrogen-doped graphene/PDDA/gold nanoparticle composites for electrochemical detection of uric acid
    Xi Pang
    Fusen Li
    Songqing Huang
    Zeqi Yang
    Qian Mo
    Li Huang
    Wanpeng Xu
    Limin Chen
    Xinchun Li
    Analytical and Bioanalytical Chemistry, 2020, 412 : 669 - 680
  • [33] Chemometric Strategies to Develop a Nanocomposite Electrode for Simultaneous Determination of Ascorbic Acid, Dopamine, and Uric Acid
    Troiani, Estela de Pieri
    Pereira-Filho, Edenir Rodrigues
    Faria, Ronaldo Censi
    ELECTROANALYSIS, 2013, 25 (08) : 1988 - 1994
  • [34] Simultaneous electrochemical determination of dopamine, uric acid and ascorbic acid using palladium nanoparticle-loaded carbon nanofibers modified electrode
    Huang, Jianshe
    Liu, Yang
    Hou, Haoqing
    You, Tianyan
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (04) : 632 - 637
  • [35] Mono- and Few-Layer Nitrogen-Containing Graphenes as Sensitive Layers of Electrochemical Sensors for Selective Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    Kozarenko, O. A.
    Kondratyuk, A. S.
    Dyadyun, V. S.
    Karbivskiy, V. L.
    Koshechko, V. G.
    Pokhodenko, V. D.
    THEORETICAL AND EXPERIMENTAL CHEMISTRY, 2022, 58 (02) : 109 - 117
  • [36] Au-Pt bimetallic nanoparticles decorated on sulfonated nitrogen sulfur co-doped graphene for simultaneous determination of dopamine and uric acid
    Zhang, Kangning
    Chen, Xiaoling
    Li, Zhuang
    Wang, Yan
    Sun, Sen
    Wang, Li'na
    Guo, Tong
    Zhang, Dongxia
    Xue, Zhonghua
    Zhou, Xibin
    Lu, Xiaoquan
    TALANTA, 2018, 178 : 315 - 323
  • [37] Mono- and Few-Layer Nitrogen-Containing Graphenes as Sensitive Layers of Electrochemical Sensors for Selective Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid
    O. A. Kozarenko
    A. S. Kondratyuk
    V. S. Dyadyun
    V. L. Karbivskiy
    V. G. Koshechko
    V. D. Pokhodenko
    Theoretical and Experimental Chemistry, 2022, 58 : 109 - 117
  • [38] Simultaneous determination of ascorbic acid, dopamine, and uric acid with polyaniline/hemin/reduced graphite oxide composite
    Aryal, Krishna Prasad
    Jeong, Hae Kyung
    CHEMICAL PHYSICS LETTERS, 2021, 768
  • [39] Tailoring properties of polyaniline for simultaneous determination of a quaternary mixture of ascorbic acid, dopamine, uric acid, and tryptophan
    Prathap, M. U. Anu
    Srivastava, Rajendra
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 239 - 250
  • [40] A facile approach to synthesis methylene blue/reduced graphene oxide nanocomposite and simultaneous determination of dopamine and uric acid
    Haoran Wang
    Tongtong Cao
    Yicheng Zhou
    Lin Liu
    Xiaobo Zhang
    Zhiwei Tong
    Journal of Applied Electrochemistry, 2022, 52 : 1067 - 1080