Finite Element Analysis of Horizontal Screw- Screw Crosslink Used in C1-C2 Pedicle Screw- Rod Fixation

被引:9
作者
Ouyang, Beiping [1 ,2 ,3 ]
Zou, Xiaobao [1 ,2 ]
Luo, Chunshan [3 ]
Lu, Tingsheng [3 ]
Xia, Hong [2 ]
Ma, Xiangyang [1 ,2 ]
机构
[1] Southern Med Univ, Sch Clin Med 1, Guangzhou, Guangdong, Peoples R China
[2] Gen Hosp Southern Theater Command Peoples Liberat, Dept Spinal Surg, Guangzhou, Guangdong, Peoples R China
[3] Guizhou Orthoped Hosp, Dept Spine Surg, Guiyang, Guizhou, Peoples R China
来源
MEDICAL SCIENCE MONITOR | 2021年 / 27卷
基金
中国国家自然科学基金;
关键词
Atlanto-Axial Fusion; Biomechanical Phenomena; Finite Element Analysis; Internal Fixators; POSTERIOR ATLANTOAXIAL FIXATION; BIOMECHANICAL ANALYSIS; CONSTRUCTS; DISLOCATION; ADVANTAGES; REDUCTION; C1;
D O I
10.12659/MSM.932026
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: In the craniocervical junction, a C1-C2 pedicle screw-rod (PSR) fixation is applied to provide stability. The horizontal rod-rod crosslink (hR-R CL) is often used to enhance segmental posterior instrumentation. However, the biomechanics of the alternative horizontal screw-screw crosslink (hS-S CL) in the craniocervical junction are unclear. Material/Methods: A nonlinear atlantoaxial instability 3-dimensional C1-C2 finite element model was constructed using computed tomography images. On this basis, 2 fixation models were established with C1-C2 PSR fixation using (1) a rod-rod crosslink (R-R CL), and (2) a screw-screw crosslink (S-S CL). Range of motion (ROM) of the atlantoaxial joint, stress distribution of the implants, and maximum stress value of the vertebral bodies were calculated and compared under 4 loading conditions, including flexion, extension, lateral bending, and axial rotation. Results: Atlantoaxial joint ROM was reduced by 90.19% to 98.5% with the hR-R CL, and by 90.1% to 98.7% with the hS-S CL, compared with the instability model. During axial rotation, the total stress peak of the PSR fixation was smaller with hS-S CL than with hR-R CL. The peak stress values of the vertebral bodies were comparable between the 2 fixation models. Conclusions: The 2 tested crosslink models provided comparable stability. However, during axial rotation, the total stress peak of hS-S CL fixation was smaller than that of hR-R CL fixation. Since the atlantoaxial joint primarily functions as a rotational joint, our results suggested that the use of hS-S CL can provide a more stable environment for the implants.
引用
收藏
页数:8
相关论文
共 22 条
[1]   Posterior Atlantoaxial Fixation with Screw-Rod Constructs: Safety, Advantages, and Shortcomings [J].
Bhowmick, Deb A. ;
Benzel, Edward C. .
WORLD NEUROSURGERY, 2014, 81 (02) :288-289
[2]   Stabilization of the Atlantoaxial Joint With C1-C3 Lateral Mass Screw Constructs: Biomechanical Comparison With Standard Technique [J].
Brasiliense, Leonardo B. C. ;
Lazaro, Bruno C. R. ;
Reyes, Phillip M. ;
Fox, Douglas ;
Sonntag, Volker K. H. ;
Crawford, Neil R. .
NEUROSURGERY, 2010, 67 :ons422-ons427
[3]  
Brodke D S, 2001, Spine J, V1, P373, DOI 10.1016/S1529-9430(01)00116-4
[4]   Evaluation of biomechanical properties of anterior atlantoaxial transarticular locking plate system using three-dimensional finite element analysis [J].
Cai, Xian-hua ;
Liu, Zhi-chao ;
Yu, Yang ;
Zhang, Mei-chao ;
Huang, Wei-bing .
EUROPEAN SPINE JOURNAL, 2013, 22 (12) :2686-2694
[5]   Biomechanical Comparison of Four Different Atlantoaxial Posterior Fixation Constructs in Adults A Finite Element Study [J].
Chun, Dong Hyun ;
Yoon, Do Heum ;
Kim, Keung Nyun ;
Yi, Seong ;
Shin, Dong Ah ;
Ha, Yoon .
SPINE, 2018, 43 (15) :E891-E897
[6]   Cross-links in posterior pedicle screw-rod instrumentation of the spine: a systematic review on mechanical, biomechanical, numerical and clinical studies [J].
Cornaz, Frederic ;
Widmer, Jonas ;
Snedeker, Jess Gerrit ;
Spirig, Jose Miguel ;
Farshad, Mazda .
EUROPEAN SPINE JOURNAL, 2021, 30 (01) :34-49
[7]   Biomechanical analysis of screw constructs for atlantoaxial fixation in cadavers: a systematic review and meta-analysis [J].
Du, Jerry Y. ;
Aichmair, Alexander ;
Kueper, Janina ;
Wright, Timothy ;
Lebl, Darren R. .
JOURNAL OF NEUROSURGERY-SPINE, 2015, 22 (02) :151-161
[8]   Nonlinear finite element analysis of C0-C1-C2 complex under physiologic loads [J].
Hao Zhang ;
Jing Bai .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :6165-6167
[9]   Mechanical stiffness of segmental versus nonsegmental pedicle screw constructs:: The effect of cross-links [J].
Hart, R ;
Hettwer, W ;
Liu, Q ;
Prem, S .
SPINE, 2006, 31 (02) :E35-E38
[10]   Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability [J].
Huang, Da-Geng ;
Wang, Tao ;
Hao, Ding-Jun ;
He, Bao-Rong ;
Liu, Tuan-Jiang ;
Ma, Xiao-Wen ;
Yu, Cheng-Cheng ;
Feng, Hang ;
Zhao, Song-Chum ;
Hui, Hua .
CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 :71-75