Survival Rate of Short, Locking Taper Implants with a Plateau Design: A 5-Year Retrospective Study

被引:15
作者
Demiralp, Kemal Ozgur [1 ]
Akbulut, Nihat [2 ]
Kursun, Sebnem [3 ]
Argun, Didem [4 ]
Bagis, Nilsun [5 ]
Orhan, Kaan [6 ]
机构
[1] Minist Hlth, Publ Hosp Agcy Turkey, TR-06520 Ankara, Turkey
[2] Gaziosmanpasa Univ, Fac Dent, Oral & Maxillofacial Surg Dept, TR-60150 Tokat, Turkey
[3] Minist Hlth, Bolu Oral & Dent Hlth Ctr, Div Dentomaxillofacial Radiol, TR-14300 Bolu, Turkey
[4] Special Clin Practice, TR-06490 Ankara, Turkey
[5] Ankara Univ, Fac Dent, Dept Periodontol, TR-06500 Ankara, Turkey
[6] Ankara Univ, Fac Dent, Dentomaxillofacial Radiol Dept, TR-06500 Ankara, Turkey
关键词
SINGLE-TOOTH; 6-MM-LONG IMPLANTS; PLACEMENT; SURFACE;
D O I
10.1155/2015/197451
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background. Short implants have become popular in the reconstruction of jaws, especially in cases with limited bone height. Shorter implants, those with locking tapers and plateau root shapes, tend to have longer survival times. We retrospectively investigated the cumulative survival rates of Bicon short implants (<8 mm) according to patient variables over a 5-year period. Materials and Methods. This study included 111 consecutively treated patients with 371 implants supporting fixed or removable prosthetics. Data were evaluated to acquire cumulative survival rates according to gender, age, tobacco use, surgical procedure, bone quality, and restoration type. Statistics were performed using chi-square, Mann-Whitney, and Kruskal Wallis H tests. Results. The survival rate was 97.3% with, on average, 22.8 months of follow-up. Patients older than 60 years had higher failure rate than the other age groups (P < 0.05). Placed region, age, and bone quality had adverse effects on survival rate in the <8 mm implant group with statistically significant difference (P < 0.05). Conclusions. Approximately 23-month follow-up data indicate that short implants with locking tapers and plateau-type roots have comparable survival rates as other types of dental implants. However, due to limitations of study, these issues remain to be further investigated in future randomized controlled clinical trials.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW
    ADELL, R
    LEKHOLM, U
    ROCKLER, B
    BRANEMARK, PI
    [J]. INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06): : 387 - 416
  • [2] Clinical and radiographic changes at implants supporting single-unit crowns (SCs) and fixed dental prostheses (FDPs) with one cantilever extension. A retrospective study
    Aglietta, Marco
    Siciliano, Vincenzo Iorio
    Blasi, Andrea
    Sculean, Anton
    Braegger, Urs
    Lang, Niklaus P.
    Salvi, Giovanni E.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (05) : 550 - 555
  • [3] Finite element stress analysis of the effect of short implant usage in place of cantilever extensions in mandibular posterior edentulism
    Akça, K
    Iplikçioglu, H
    [J]. JOURNAL OF ORAL REHABILITATION, 2002, 29 (04) : 350 - 356
  • [4] Short Dental Implants: A Systematic Review
    Annibali, S.
    Cristalli, M. P.
    Dell'Aquila, D.
    Bignozzi, I.
    La Monaca, G.
    Pilloni, A.
    [J]. JOURNAL OF DENTAL RESEARCH, 2012, 91 (01) : 25 - 32
  • [5] Early Bone Healing around Different Implant Bulk Designs and Surgical Techniques: A Study in Dogs
    Coelho, Paulo G.
    Suzuki, Marcelo
    Guimaraes, Marcia V. M.
    Marin, Charles
    Granato, Rodrigo
    Gil, Jose N.
    Miller, Robert J.
    [J]. CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (03) : 202 - 208
  • [6] Dibart S, 2005, INT J ORAL MAX IMPL, V20, P732
  • [7] Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible
    Draenert, Florian G.
    Sagheb, Keyvan
    Baumgardt, Katharina
    Kaemmerer, Peer W.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (09) : 1063 - 1069
  • [8] Gentile MA, 2005, INT J ORAL MAX IMPL, V20, P930
  • [9] Goene Ronnie, 2005, Implant Dent, V14, P274, DOI 10.1097/01.id.0000173335.90854.d8
  • [10] Kido H, 1997, J Oral Implantol, V23, P163