A Distance-Based Microfluidic Paper-Based Biosensor for Glucose Measurements in Tear Range

被引:30
作者
Allameh, Samira [1 ]
Rabbani, Mohsen [1 ]
机构
[1] Univ Isfahan, Fac Engn, Dept Biomed Engn, Esfahan, Iran
关键词
Microfluidic paper-based analytical device (mu PAD); Glucose; Colorimetric detection; CO2; laser; Paper; Tears; DEVICES MU-PADS; COLORIMETRIC DETECTION; URIC-ACID;
D O I
10.1007/s12010-022-03817-8
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The prevalence of diabetes has increased over the past years. Therefore, developing minimally invasive, user-friendly, and cost-effective glucose biosensors is necessary especially in low-income and developing countries. Cellulose paper-based analytical devices have attracted the attention of many researchers due to affordability, not requiring trained personnel, and complex equipment. This paper describes a microfluidic paper-based analytical device (mu PAD) for detecting glucose concentration in tear range with the naked eye. The paper-based biosensor fabricated by laser CO2; and glucose oxidase/horseradish peroxidase (GOx/HRP) enzyme solution coupled with tetramethylbenzidine (TMB) were utilized as reagents. A sample volume of 10 mu l was needed for the biosensor operation and the results were observable within 5 min. The color intensity-based and distance-based results were analyzed by ImageJ and Tracker to evaluate the device performance. Distance-based results showed a linear behavior in 0.1-1.2 mM with an R-2 = 0.9962 and limit of detection (LOD) of 0.1 mM. The results could be perceived by the naked eye without needing additional equipment or trained personnel in a relatively short time (3-5 min).
引用
收藏
页码:2077 / 2092
页数:16
相关论文
共 44 条
[11]  
Ghosh R., 2019, FABRICATION LASER PR, P1, DOI [10.1038/s41598-019-44455-1, DOI 10.1038/S41598-019-44455-1]
[12]   Fabrication of paper-based microfluidic analysis devices: a review [J].
He, Yong ;
Wu, Yan ;
Fu, Jian-Zhong ;
Wu, Wen-Bin .
RSC ADVANCES, 2015, 5 (95) :78109-78127
[13]   Ultrasmall Pt Nanoclusters as Robust Peroxidase Mimics for Colorimetric Detection of Glucose in Human Serum [J].
Jin, Lihua ;
Meng, Zheng ;
Zhang, Yongqing ;
Cai, Shijie ;
Zhang, Zaihua ;
Li, Cong ;
Shang, Li ;
Shen, Yehua .
ACS APPLIED MATERIALS & INTERFACES, 2017, 9 (11) :10027-10033
[14]   A Lab-on-a-Chip-Based Non-Invasive Optical Sensor for Measuring Glucose in Saliva [J].
Jung, Dong Geon ;
Jung, Daewoong ;
Kong, Seong Ho .
SENSORS, 2017, 17 (11)
[15]   Colorimetric Schirmer Strip for Tear Glucose Detection [J].
Kang, Byoung-Hoon ;
Park, Moonseong ;
Jeong, Ki-Hun .
BIOCHIP JOURNAL, 2017, 11 (04) :294-299
[16]   Tear Glucose Measurement by Reflectance Spectrum of a Nanoparticle Embedded Contact Lens [J].
Kim, Sooyeon ;
Jeon, Hee-Jae ;
Park, Sijin ;
Lee, Dong Yun ;
Chung, Euiheon .
SCIENTIFIC REPORTS, 2020, 10 (01)
[17]   Microfluidic Paper-Based Analytical Device for Histidine Determination [J].
Kugimiya, Akimitsu ;
Fujikawa, Akane ;
Jiang, Xiao ;
Fan, Z. Hugh ;
Nishida, Toshikazu ;
Kohda, Jiro ;
Nakano, Yasuhisa ;
Takano, Yu .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2020, 192 (03) :812-821
[18]   Self-monitoring of tear glucose: the development of a tear based glucose sensor as an alternative to self-monitoring of blood glucose [J].
La Belle, Jeffrey T. ;
Adams, Anngela ;
Lin, Chi-En ;
Engelschall, Erica ;
Pratta, Breanna ;
Cook, Curtiss B. .
CHEMICAL COMMUNICATIONS, 2016, 52 (59) :9197-9204
[19]   Tear glucose dynamics in diabetes mellitus [J].
Lane, Jennifer D. ;
Krumholz, David M. ;
Sack, Robert A. ;
Morris, Carol .
CURRENT EYE RESEARCH, 2006, 31 (11) :895-901
[20]   A "green" cellulose paper based glucose amperometric biosensor [J].
Lawrence, Chee Shiong Kuek ;
Tan, Swee Ngin ;
Floresca, Christina Zerda .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 :536-541