Method of simulating dose reduction for digital radiographic systems

被引:62
作者
Båth, M
Håkansson, M
Tingberg, A
Månsson, LG
机构
[1] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41345 Gothenburg, Sweden
[2] Malmo Univ Hosp, Dept Radiat Phys, SE-20502 Malmo, Sweden
关键词
D O I
10.1093/rpd/nch540
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The optimisation of image quality vs. radiation dose is an important task in medical imaging. To obtain maximum validity of the optimisation, it must be based on clinical images. Images at different dose levels can then either be obtained by collecting patient images at the different dose levels sought to investigate-including additional exposures and permission from an ethical committee-or by manipulating images to simulate different dose levels. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems. The method uses information about the detective quantum efficiency and noise power spectrum at the original and simulated dose levels to create an image containing filtered noise. When added to the original image this results in an image with noise which, in terms of frequency content, agrees with the noise present in an image collected at the simulated dose level. To increase the validity, the method takes local dose variations in the original image into account. The method was tested on a computed radiography system and was shown to produce images with noise behaviour similar to that of images actually collected at the simulated dose levels. The method can, therefore, be used to modify an image collected at one dose level so that it simulates an image of the same object collected at any lower dose level.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 25 条
[1]   A conceptual optimisation strategy for radiography in a digital environment [J].
Båth, M ;
Håkansson, M ;
Hansson, J ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :230-235
[2]   Nodule detection in digital chest radiography:: Part of image background acting as pure noise [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Bochud, FO ;
Verdun, FR ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :102-108
[3]   Nodule detection in digital chest radiography:: Introduction to the radius chest trial [J].
Båth, M ;
Håkansson, M ;
Börjesson, S ;
Kheddache, S ;
Grahn, A ;
Ruschin, M ;
Tingberg, A ;
Mattsson, S ;
Månsson, LG .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :85-91
[4]   Determination of the two-dimensional detective quantum efficiency of a computed radiography system [J].
Båth, M ;
Håkansson, M ;
Månsson, LG .
MEDICAL PHYSICS, 2003, 30 (12) :3172-3182
[5]   Method for determining the two-dimensional presampling modulation transfer function in digital radiography [J].
Båth, M ;
Sund, P ;
Månsson, LG .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :268-279
[6]  
BATH M, 2003, THESIS GOTEBORG U GO
[7]   Estimation of the noisy component of anatomical backgrounds [J].
Bochud, FO ;
Valley, JF ;
Verdun, FR ;
Hessler, C ;
Schnyder, P .
MEDICAL PHYSICS, 1999, 26 (07) :1365-1370
[8]   Further investigation of the effect of phase spectrum on visual detection in structured backgrounds [J].
Bochud, FO ;
Abbey, CK ;
Eckstein, MP .
MEDICAL IMAGING 1999: IMAGE PERCEPTION AND PERFORMANCE, 1999, 3663 :273-281
[9]   Human observer detection experiments with mammograms and power-law noise [J].
Burgess, AE ;
Jacobson, FL ;
Judy, PF .
MEDICAL PHYSICS, 2001, 28 (04) :419-437
[10]  
Dobbins JT, 2000, HDB MED IMAGING, P161, DOI DOI 10.1117/3.832716.CH3