Biomechanical effects of osteoplasty with or without Kirschner wire augmentation on long bone diaphyses undergoing bending stress: implications for percutaneous imaging-guided consolidation in cancer patients

被引:11
作者
Cazzato, Roberto Luigi [1 ]
Koch, Guillaume [1 ]
Garnon, Julien [1 ]
Ramamurthy, Nitin [2 ]
Jegu, Jeremie [3 ]
Clavert, Philippe [4 ]
Gangi, Afshin [1 ]
机构
[1] Nouvel Hop Civil Hop Univ Strasbou, Dept Intervent Radiol, HUS, 1 Pl Hop, F-67000 Strasbourg, France
[2] Norfolk & Norwich Univ Hosp, Dept Radiol, Colney Lane, Norwich NR4 7UY, Norfolk, England
[3] Univ Strasbourg, Lab Epidemiol & Sante Publ EA3430, 4 Rue Kirschleger, F-67085 Strasbourg, France
[4] Hop Univ Strasbourg, Dept Normal Anat, HUS France, 1 Pl Hop, F-67000 Strasbourg, France
关键词
Bone wires; Diaphyses; Fractures (bone); Polymethyl methacrylate; INTERVENTIONAL INTERNAL-FIXATION; MINIMALLY INVASIVE SURGERY; FEMORAL-NECK FRACTURES; HIGH-RISK PATIENTS; PATHOLOGICAL FRACTURES; CEMENT AUGMENTATION; MALIGNANT LESIONS; FLEXIBLE NAILS; CEMENTOPLASTY; FEMOROPLASTY;
D O I
10.1186/s41747-018-0082-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Osteoplasty has been discouraged in long bones. However, despite a substantial lack of pre-clinical biomechanical tests, multiple clinical studies have implemented a wide range of techniques to optimise long bone osteoplasty. The aim of the present study is to evaluate the biomechanical properties of osteoplasty alone and in combination with Kirschner wires (K-wires) in a cadaveric human diaphyseal model undergoing 3-point bending stress. Methods Thirty unpaired human cadaveric hemi-tibia specimens were randomly assigned to receive no consolidation (group 1, n = 10), osteoplasty alone (group 2, n = 10), or K-wires augmented osteoplasty (group 3, n = 10). Specimens were tested on a dedicated servo-hydraulic machine using a 3-point bending test. Fracture load was calculated for each specimen; two-sample Wilcoxon rank-sum tests were used to assess differences between groups. Results Median volume of polymethyl methacrylate injected was 18 mL for group 2 (25th-50th percentile 15-21 mL) and 19 mL for group 3 (25th-50th percentile 17-21). There were no significant differences in fracture load between groups 1 and 2 (z = - 0.793; p = 0.430), between groups 1 and 3 (z = - 0.944; p = 0.347), and between groups 2 and 3 (z = - 0.454; p = 0.650). Fractures through the cement occurred in 4 of 30 cases (13.3%); there were no K-wires fractures. Conclusions Osteoplasty with or without K-wires augmentation does not improve the resistance of diaphyseal bone to bending stresses.
引用
收藏
页数:9
相关论文
共 34 条
  • [31] Comparison of Percutaneous Cementoplasty with and Without Interventional Internal Fixation for Impending Malignant Pathological Fracture of the Proximal Femur
    Tian, Qing-Hua
    He, Cheng-Jian
    Wu, Chun-Gen
    Li, Yong-Dong
    Gu, Yi-Feng
    Wang, Tao
    Xiao, Quan-Ping
    Li, Ming-Hua
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2016, 39 (01) : 81 - 89
  • [32] New approaches for cement-based prophylactic augmentation of the osteoporotic proximal femur provide enhanced reinforcement as predicted by non-linear finite element simulations
    Varga, Peter
    Inzana, Jason A.
    Schwiedrzik, Jakob
    Zysset, Philippe K.
    Gueorguiev, Boyko
    Blauth, Michael
    Windolf, Markus
    [J]. CLINICAL BIOMECHANICS, 2017, 44 : 7 - 13
  • [33] Treatment of pathological fractures of the long bones
    Willeumier, Julie J.
    van der Linden, Yvette M.
    van de Sande, Michiel A. J.
    Dijkstra, P. D. Sander
    [J]. EFORT OPEN REVIEWS, 2016, 1 (05): : 136 - 145
  • [34] Yurdoglu C, 1997, ACTA ORTHOP TRAUMATO, V31, P250