Local and Central Control of a Wind Farm for Active Power Adjustment

被引:0
作者
Masmoud, Abdelkarim [1 ]
Abdelkafi, Chraf [1 ]
Krichen, Lotfi [1 ]
Saidi, Abdelaziz Salah [2 ,3 ]
机构
[1] Univ Sfa, Natl Engn Sch Sfax, Elect Syst & Renewable Energies Lab LSEER, Sfax, Tunisia
[2] King Khalid Univ, Dept Elect Engn, POB 394, Abha 61411, Saudi Arabia
[3] Univ Tunis El Mana, Natl Engn Sch Tunis, Elect Sys Lab, Tunis, Tunisia
来源
INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH | 2022年 / 12卷 / 02期
关键词
Wind farm; pitch control; power balance; central and local control; MPPT; LPPT; FREQUENCY CONTROL; CONTROL STRATEGY; SYSTEM; MANAGEMENT; TURBINE;
D O I
10.20508/ijrer.v12i2.12848.g8467
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The work presented in this paper deals with the active power control in a wind faun based on both central and local control levels. A central supervision unit (CSU) ensures the power coordination between the local supervision units (LSU) of each wind turbine. In the local supervision unit, a power management has been developed in order to adjust the distribution of the faun's production. The main contribution of the developed work is the adjustment of the delivered power by each wind turbine using an additional control of the pitch angle. Consequently, power control flexibility for the wind faun system was established by considering either maximum power point tracking (MPPT) mode or limited power point tracking (LPPT) mode. Therefore, the LSU inside each wind turbine control effectively coordinates with the power distribution received from the CSU according to the wind faun available power. Simulation results presented in this paper have shown the good performance and the high stability of the proposed supervision strategy for the considered wind faun.
引用
收藏
页码:819 / 826
页数:8
相关论文
共 28 条
[1]   New strategy of pitch angle control for energy management of a wind farm [J].
Abdelkafi, Achraf ;
Krichen, Lotfi .
ENERGY, 2011, 36 (03) :1470-1479
[2]   Grid-connected renewable energy sources: Review of the recent integration requirements and control methods [J].
Al-Shetwi, Ali Q. ;
Hannan, M. A. ;
Jern, Ker Pin ;
Mansur, M. ;
Mahlia, T. M., I .
JOURNAL OF CLEANER PRODUCTION, 2020, 253
[3]   Active power control design for supporting grid frequency regulation in wind farms [J].
Badihi, Hamed ;
Zhang, Youmin ;
Hong, Henry .
ANNUAL REVIEWS IN CONTROL, 2015, 40 :70-81
[4]   Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm [J].
Cartwright, P ;
Holdsworth, L ;
Ekanayake, JB ;
Jenkins, N .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (04) :495-502
[5]   Connection requirements for wind farms:: A survey on technical requierements and regulation [J].
de Alegria, Inigo Martinez ;
Andreu, Jon ;
Martin, Jos Luis ;
Ibanez, Pedro ;
Villate, Jose Luis ;
Camblong, Haritza .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2007, 11 (08) :1858-1872
[6]   Robust local controllers design for the AC grid voltage control of an offshore wind farm [J].
Diaz-Sanahuja, Carlos ;
Penarrocha-Alos, Ignacio ;
Vidal-Albalate, Ricardo .
IFAC PAPERSONLINE, 2020, 53 (02) :12751-12756
[7]   Inertia response and frequency control techniques for renewable energy sources: A review [J].
Dreidy, Mohammad ;
Mokhlis, H. ;
Mekhilef, Saad .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2017, 69 :144-155
[8]   A novel optimizing power control strategy for centralized wind farm control system [J].
Ebrahimi, F. M. ;
Khayatiyan, A. ;
Farjah, E. .
RENEWABLE ENERGY, 2016, 86 :399-408
[9]   Optimal energy management system for stand-alone wind turbine/photovoltaic/hydrogen/battery hybrid system with supervisory control based on fuzzy logic [J].
Garcia, Pablo ;
Torreglosa, Juan P. ;
Fernandez, Luis M. ;
Jurado, Francisco .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (33) :14146-14158
[10]   Flicker mitigation by reactive power control in wind farm with doubly fed induction generators [J].
Girbau-Llistuella, Francesc ;
Sumper, Andreas ;
Diaz-Gonzalez, Francisco ;
Galceran-Arellano, Samuel .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 55 :285-296