In vitro corrosion study of PLA/Mg composites for cardiovascular stent applications

被引:22
作者
Hasanpur, Ehsan [1 ]
Ghazavizadeh, Akbar [2 ]
Sadeghi, Alireza [1 ]
Haboussi, Mohamed [2 ]
机构
[1] Univ Tehran, Sch Mech Engn, Coll Engn, Tehran, Iran
[2] Univ Sorbonne Paris Nord, CNRS, LSPM, Sorbonne Paris Cite,UPR3407, Ave Jean Baptiste Clement, F-93430 Villetaneuse, France
关键词
Patient-specific cardiovascular stents; PLA; Mg biocomposites; Biodegradable polymeric stents; In-vitro corrosion testing; ACID CORONARY STENTS; MECHANICAL-BEHAVIOR; ELUTING STENTS; POLYLACTIDE; MAGNESIUM; CRYSTALLINITY; IMPLANTATION; DEGRADATION; PLLA/MAGNESIUM; THROMBOSIS;
D O I
10.1016/j.jmbbm.2021.104768
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The present investigation explores the impact of Mg volume fraction (VMg) as a controlling parameter of degradation rate in designing patient-specific cardiovascular stents made of PLA/Mg composites. For the purpose of this research, PLA/Mg composite plates containing 1, 3, 5, and 10% VMg are produced by melt blending and hot press molding. Characterization techniques such as scanning electron microscopy (SEM), differential scanning calorimetry (DSC) and X-ray diffraction (XRD) are employed to study the microstructure of PLA/Mg composites. For in vitro corrosion tests, stent prototypes and composite samples are immersed in baths of simulated body fluid (SBF). According to in vitro corrosion tests, increasing VMg increases the corrosion rate of the composites by accelerating the corrosion of the particles and the crystalline zones surrounding them. In addition, a 2% raise in the Mg content (from 1% to 3%), increases the overall Mg weight loss by more than 4 times. Composite samples and prototype stents containing more than 5% VMg exhibit cracking and brittleness after 7 days of immersion in SBF. In light of the compression tests results and also the failures and cracks observed during immersions, the upper limit of Mg content for PLA/Mg stent fabrication purposes is found to be below 3%.
引用
收藏
页数:12
相关论文
共 45 条
[1]   AMS INSIGHT-Absorbable Metal Stent Implantation for Treatment of Below-the-Knee Critical Limb Ischemia: 6-Month Analysis [J].
Bosiers, Marc .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (03) :424-435
[2]   Porous magnesium/PLGA composite scaffolds for enhanced bone regeneration following tooth extraction [J].
Brown, Andrew ;
Zaky, Samer ;
Ray, Herbert, Jr. ;
Sfeir, Charles .
ACTA BIOMATERIALIA, 2015, 11 :543-553
[3]   Effect of Mg content on the thermal stability and mechanical behaviour of PLLA/Mg composites processed by hot extrusion [J].
Cifuentes, S. C. ;
Lieblich, M. ;
Lopez, F. A. ;
Benavente, R. ;
Gonzalez-Carrasco, J. L. .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 72 :18-25
[4]   Assessment of mechanical behavior of PLA composites reinforced with Mg micro-particles through depth-sensing indentations analysis [J].
Cifuentes, S. C. ;
Frutos, E. ;
Benavente, R. ;
Lorenzo, V. ;
Gonzalez-Carrasco, J. L. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 65 :781-790
[5]   In vitro degradation of biodegradable polylactic acid/magnesium composites: Relevance of Mg particle shape [J].
Cifuentes, S. C. ;
Gavilan, R. ;
Lieblich, M. ;
Benavente, R. ;
Gonzalez-Carrasco, J. L. .
ACTA BIOMATERIALIA, 2016, 32 :348-357
[6]   Novel PLLA/magnesium composite for orthopedic applications: A proof of concept [J].
Cifuentes, S. C. ;
Frutos, E. ;
Gonzalez-Carrasco, J. L. ;
Munoz, M. ;
Multigner, M. ;
Chao, J. ;
Benavente, R. ;
Lieblich, M. .
MATERIALS LETTERS, 2012, 74 :239-242
[7]   Incorporation of Mg particles into PDLLA regulates mesenchymal stem cell and macrophage responses [J].
Cifuentes, Sandra C. ;
Bensiamar, Fatima ;
Gallardo-Moreno, Amparo M. ;
Osswald, Tim A. ;
Gonzalez-Carrasco, Jose L. ;
Benavente, Rosario ;
Gonzalez-Martin, Maria L. ;
Garcia-Rey, Eduardo ;
Vilaboa, Nuria ;
Saldana, Laura .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2016, 104 (04) :866-878
[8]   Randomized study to assess the effectiveness of slow- and moderate-release polymer-based paclitaxel-eluting stents for coronary artery lesions [J].
Colombo, A ;
Drzewiecki, J ;
Banning, A ;
Grube, E ;
Hauptmann, K ;
Silber, S ;
Dudek, D ;
Fort, S ;
Schiele, F ;
Zmudka, K ;
Guagliumi, G ;
Russell, ME .
CIRCULATION, 2003, 108 (07) :788-794
[9]   Mechanical and hydrolytic properties of thin polylactic acid films by fused filament fabrication [J].
Ekinci, Alper ;
Gleadall, Andy ;
Johnson, Andrew A. ;
Li, Ling ;
Han, Xiaoxiao .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 114
[10]   Development of biocompatible and fully bioabsorbable PLA/Mg films for tissue regeneration applications [J].
Ferrandez-Montero, A. ;
Lieblich, M. ;
Gonzalez-Carrasco, J. L. ;
Benavente, R. ;
Lorenzo, V. ;
Detsch, R. ;
Boccaccini, A. R. ;
Ferrari, B. .
ACTA BIOMATERIALIA, 2019, 98 :114-124