Design and assessment of a novel SPECT system for desktop open-gantry imaging of small animals: A simulation study

被引:7
作者
Zeraatkar, Navid [1 ]
Farahani, Mohammad Hossein [1 ]
Rahmim, Arman [2 ,3 ]
Sarkar, Saeed [4 ,5 ]
Ay, Mohammad Reza [1 ,4 ]
机构
[1] Univ Tehran Med Sci, Res Ctr Mol & Cellular Imaging, Tehran 1419733141, Iran
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
[4] Univ Tehran Med Sci, Dept Med Phys & Biomed Engn, Tehran 1417613151, Iran
[5] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran 1419733141, Iran
关键词
SPECT; tomography; small-animal imaging; pinhole; tilted detector; HIGH-RESOLUTION; GAMMA-CAMERA; ANALYTIC DETERMINATION; PINHOLE COLLIMATION; EFFECTIVE DIAMETER; PERFORMANCE; RECONSTRUCTION; SENSITIVITY; PET; CT;
D O I
10.1118/1.4947127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Given increasing efforts in biomedical research utilizing molecular imaging methods, development of dedicated high-performance small-animal SPECT systems has been growing rapidly in the last decade. In the present work, we propose and assess an alternative concept for SPECT imaging enabling desktop open-gantry imaging of small animals. Methods: The system, PERSPECT, consists of an imaging desk, with a set of tilted detector and pinhole collimator placed beneath it. The object to be imaged is simply placed on the desk. Monte Carlo (MC) and analytical simulations were utilized to accurately model and evaluate the proposed concept and design. Furthermore, a dedicated image reconstruction algorithm, finite-aperture-based circular projections (FABCP), was developed and validated for the system, enabling more accurate modeling of the system and higher quality reconstructed images. Image quality was quantified as a function of different tilt angles in the acquisition and number of iterations in the reconstruction algorithm. Furthermore, more complex phantoms including Derenzo, Defrise, and mouse whole body were simulated and studied. Results: The sensitivity of the PERSPECT was 207 cps/MBq. It was quantitatively demonstrated that for a tilt angle of 30 degrees, comparable image qualities were obtained in terms of normalized squared error, contrast, uniformity, noise, and spatial resolution measurements, the latter at similar to 0.6 mm. Furthermore, quantitative analyses demonstrated that 3 iterations of FABCP image reconstruction (16 subsets/iteration) led to optimally reconstructed images. Conclusions: The PERSPECT, using a novel imaging protocol, can achieve comparable image quality performance in comparison with a conventional pinhole SPECT with the same configuration. The dedicated FABCP algorithm, which was developed for reconstruction of data from the PERSPECT system, can produce high quality images for small-animal imaging via accurate modeling of the system as incorporated in the forward- and back-projection steps. Meanwhile, the developed MC model and the analytical simulator of the system can be applied for further studies on development and evaluation of the system. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:2581 / 2597
页数:17
相关论文
共 68 条
[1]   Resolution-effective diameters for asymmetric-knife-edge pinhole collimators [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (12) :1637-1646
[2]   Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator [J].
Accorsi, R ;
Metzler, SD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2004, 23 (06) :750-763
[3]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[4]   Analytical, experimental, and Monte Carlo system response matrix for pinhole SPECT reconstruction [J].
Aguiar, Pablo ;
Pino, Francisco ;
Silva-Rodriguez, Jesus ;
Pavia, Javier ;
Ros, Domenec ;
Ruibal, Alvaro ;
El Bitar, Ziad .
MEDICAL PHYSICS, 2014, 41 (03)
[5]  
Anger H.O., 1967, INSTRUMENTATION NUCL, V1, P485
[6]  
[Anonymous], 2013, NANOSCAN FAM PRECL S
[7]   Molecular Imaging of Conscious, Unrestrained Mice with AwakeSPECT [J].
Baba, Justin S. ;
Endres, Christopher J. ;
Foss, Catherine A. ;
Nimmagadda, Sridhar ;
Jung, Hyeyun ;
Goddard, James S. ;
Lee, Seungjoon ;
McKisson, John ;
Smith, Mark F. ;
Stolin, Alexander V. ;
Weisenberger, Andrew G. ;
Pomper, Martin G. .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) :969-976
[8]  
Beekman FJ, 2005, J NUCL MED, V46, P1194
[9]   Comparison of pinhole collimator materials based on sensitivity equivalence [J].
Bom, Victor ;
Goorden, Marlies ;
Beekman, Freek .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (11) :3199-3214
[10]  
Choong W., 2003, IEEE NUCL SCI S