Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:6
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Pharmacokinetic drug interactions of morphine, codeine, and their derivatives: Theory and clinical reality, part II [J].
Armstrong, SC ;
Cozza, KL .
PSYCHOSOMATICS, 2003, 44 (06) :515-520
[2]   DETERMINATION OF CODEINE, DIONIN AND THEBAINE BY DIFFERENTIAL PULSE POLAROGRAPHY [J].
BAIULESCU, GE ;
POPESCU, SD .
ANALYTICAL LETTERS, 1986, 19 (5-6) :587-596
[3]  
Bard AJ, 2001, ELECTROCHEMICAL METH
[4]  
Edebi V.N., 2011, Afr. J. Pure Appl. Chem., V5, P104
[5]   Plastic membrane electrodes for the potentiometric determination of codeine in pharmaceutical preparations [J].
Elnemma, EM ;
Hamada, MA .
MIKROCHIMICA ACTA, 1997, 126 (1-2) :147-151
[6]   SPECTROPHOTOMETRIC DETERMINATION OF ACETAMINOPHEN, SALICYLAMIDE AND CODEINE PHOSPHATE IN TABLETS [J].
ELSAYED, MAH ;
BELAL, SF ;
ELWALILY, AFM ;
ABDINE, H .
ANALYST, 1979, 104 (1240) :620-625
[7]   Voltammetric oxidation of drugs of abuse - II. Codeine and metabolites [J].
Garrido, JMPJ ;
Delerue-Matos, C ;
Borges, F ;
Macedo, TRA ;
Oliveira-Brett, AM .
ELECTROANALYSIS, 2004, 16 (17) :1427-1433
[8]  
Gomez Maria R., 2005, Farmaco (Lausanne), V60, P85, DOI 10.1016/j.farmac.2004.11.002
[9]   Simultaneous determination of codeine and caffeine using single-walled carbon nanotubes modified carbon-ceramic electrode [J].
Habibi, Biuck ;
Abazari, Mehri ;
Pournaghi-Azar, Mohammad Hossein .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2014, 114 :89-95
[10]   On the assessment of drug metabolism by assays of codeine and its main metabolites [J].
Haffen, E ;
Paintaud, G ;
Berard, M ;
Masuyer, C ;
Bechtel, Y ;
Bechtel, PR .
THERAPEUTIC DRUG MONITORING, 2000, 22 (03) :258-265