Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs

被引:5
|
作者
Piech, Robert [1 ]
Rumin, Martyna [1 ]
Paczosa-Bator, Beata [1 ]
机构
[1] AGH Univ Sci & Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
ASCORBIC-ACID; HUMAN-PLASMA; FORMULATIONS; PARACETAMOL; OXIDATION; PHOSPHATE; MORPHINE; URINE;
D O I
10.1155/2015/626458
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A glassy carbon electrode modified with a Nafion/MWCNTs composite is shown to enable the determination of codeine using differential pulse voltammetry in phosphate buffer of pH 3.0. At a preconcentration time of 15 s, the calibration graph is linear in the 0.5 mu M (0.15 mg.L-1) to 15 mu M (4.5 mg.L-1) concentration range with a correlation coefficient of 0.998. The detection limit at a preconcentration time of 120 s is as low as 4.5 mu g.L-1. The repeatability of the method at a 0.6 mu g.L-1 concentration level, expressed as the RSD, is 3.7% (for n = 5). The method was successfully applied and validated by analyzing codeine in drug, human plasma, and urine samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [2] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [3] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Li, Yamin
    Wu, Shufang
    Luo, Peili
    Liu, Jie
    Song, Ge
    Zhang, Kai
    Ye, Baoxian
    ANALYTICAL SCIENCES, 2012, 28 (05) : 497 - 502
  • [4] Electrochemical Behavior and Voltammetric Determination of Theophylline at a Glassy Carbon Electrode Modified with Graphene/Nafion
    Yamin Li
    Shufang Wu
    Peili Luo
    Jie Liu
    Ge Song
    Kai Zhang
    Baoxian Ye
    Analytical Sciences, 2012, 28 : 497 - 502
  • [5] Pulse anodic stripping voltammetric determination of copper with an amoxicillin–nafion modified glassy carbon electrode
    A. A. Ramadan
    H. Mandil
    M. A. Saleh
    Journal of Applied Electrochemistry, 2008, 38 : 1715 - 1720
  • [6] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [7] Electrochemical behavior and voltammetric determination of norfloxacin at glassy carbon electrode modified with multi walled carbon nanotubes/Nafion
    Huang, Ke-Jing
    Liu, Xue
    Xie, Wan-Zhen
    Yuan, Hong-Xia
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2008, 64 (02) : 269 - 274
  • [8] Voltammetric determination of L-dopa using a carbon nanotubes-Nafion modified glassy carbon electrode
    Xiang, Cuili
    Zou, Yongjin
    Xie, Jingjing
    Fei, Ximing
    ANALYTICAL LETTERS, 2006, 39 (13) : 2569 - 2579
  • [9] Voltammetric behavior and determination of estrogens at Nafion-modified glassy carbon electrode in the presence of cetyltrimethylammonium bromide
    Hu, SS
    Wu, KB
    Yi, HC
    Cui, DF
    ANALYTICA CHIMICA ACTA, 2002, 464 (02) : 209 - 216
  • [10] Differential pulse adsorptive stripping voltammetric determination of benzocaine and butacaine with Nafion modified glassy carbon electrode
    Reddy, Tukiakula Madhusudana
    Balaji, Kodigutta
    Reddy, Srinivasulu Jayarama Reddy
    CROATICA CHEMICA ACTA, 2006, 79 (02) : 253 - 259