Multi-material decomposition in spectral CT with angular tube voltage modulation

被引:0
作者
Su, Ting [1 ]
Zhu, Jiongtao [1 ]
Yang, Jiecheng [1 ]
Liang, Dong [1 ,2 ]
Ge, Yongshuai [1 ,2 ]
机构
[1] Chinese Acad Sci, Res Ctr Med Artificial Intelligence, Shenzhen Inst Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
[2] Chinese Acad Sci, Paul C Lauterbur Res Ctr Biomed Imaging, Shenzhen Inst Adv Technol, Shenzhen 518055, Guangdong, Peoples R China
来源
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING | 2022年 / 12031卷
关键词
Spectral CT; iterative reconstruction; voltage modulation; material decomposition;
D O I
10.1117/12.2611728
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As one of the most advanced CT imaging modalities, spectral CT plays important roles in generating material-specific information and adding vital clinical values for disease diagnosis and therapy. To obtain the spectral CT images, currently, advanced X-ray source or detector assembly is often required, which significantly increases the hardware cost and the patient burden. As a consequence, the accessibility of spectral CT is strongly limited and has not been widely implemented in daily clinics. To solve such difficulty, this work attempts to investigate a new CT data acquisition protocol and spectral CT image reconstruction algorithm. In particular, the X-ray tube voltage is slowly modulated during the gantry rotation. By doing so, spectral information that varies from one projection view to another can be acquired in one single CT scan. Afterwards, a model-based material decomposition algorithm that reconstructs the CT image from the acquired projections is utilized to perform multi-material decomposition. To evaluate the performance of this novel spectral CT imaging approach, a numerical phantom containing iodine and gadolinium solutions is imaged with different kVp modulations, i.e., different number of modulation periods per rotation. Results demonstrate that the proposed spectral CT image reconstruction algorithm can be used to accurately decompose the water, iodine and gadolinium basis images for different tube voltage modulation rates. Moreover, high-quality monochromatic images can be synthesized as well. In conclusion, a low-cost multi-material spectral CT imaging approach is developed based on the slow tube voltage modulation method.
引用
收藏
页数:6
相关论文
共 7 条
[1]   Algorithm-enabled partial-angular-scan configurations for dual-energy CT [J].
Chen, Buxin ;
Zhang, Zheng ;
Xia, Dan ;
Sidky, Emil Y. ;
Pan, Xiaochuan .
MEDICAL PHYSICS, 2018, 45 (05) :1857-1870
[2]  
Hubbell J., 1995, TABLES XRAY MASS ATT
[3]   Multi-Material Decomposition Using Statistical Image Reconstruction for Spectral CT [J].
Long, Yong ;
Fessler, Jeffrey A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) :1614-1626
[4]   A Flexible Method for Multi-Material Decomposition of Dual-Energy CT Images [J].
Mendonca, Paulo R. S. ;
Lamb, Peter ;
Sahani, Dushyant V. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (01) :99-116
[5]   Single-Scan Dual-Energy CT Using Primary Modulation [J].
Petrongolo, Michael ;
Zhu, Lei .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (08) :1799-1808
[6]   Vision 20/20: Single photon counting x-ray detectors in medical imaging [J].
Taguchi, Katsuyuki ;
Iwanczyk, Jan S. .
MEDICAL PHYSICS, 2013, 40 (10) :100901
[7]   A prototype spatial-spectral CT system for material decomposition with energy-integrating detectors [J].
Tivnan, Matthew ;
Wang, Wenying ;
Stayman, J. Webster .
MEDICAL PHYSICS, 2021, 48 (10) :6401-6411