Intramedullary nailing confers an increased risk of medial migration compared to dynamic hip screw fixation in unstable intertrochanteric hip fractures

被引:11
|
作者
Law, Gin Way [1 ]
Wong, Yoke Rung [2 ]
Gardner, Antony [3 ]
Ng, Yau Hong [1 ]
机构
[1] Natl Univ Hlth Syst, Singapore, Singapore
[2] Singapore Gen Hosp, Singapore, Singapore
[3] Ng Teng Feng Gen Hosp, Singapore, Singapore
关键词
Cephalomedullary nail; Intramedullary; PFNA; Sliding hip screw; Extramedullary; DHS; Medial migration; Cut-out; Toggling; PROXIMAL FEMORAL NAILS; GAMMA LOCKING NAIL; HELICAL BLADE; LAG SCREW; BIOMECHANICAL EVALUATION; TROCHANTERIC FRACTURES; INTERNAL-FIXATION; ADULTS YOUNGER; FAILURE; FEMUR;
D O I
10.1016/j.injury.2021.01.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Medial migration of the femoral neck element (FNE) superomedially against gravity with respect to the intramedullary component of the cephalomedullary nail is a complication increasingly recognized to cause femoral head cut-out in intramedullary nailing of pertrochanteric hip fractures. Although cut-outs are common to both intra- and extramedullary fixation, especially in unstable pertrochanteric hip fractures, FNE medial migration in sliding hip screws continues to remain sparse despite increased awareness of the phenomenon. This study aims to investigate whether intramedullary nailing is biomechanically predisposed to FNE medial migration compared to extramedullary fixation with sliding hip screws to account for the discrepancy in reported FNE medial migration rates. Materials and methods: Twelve fourth-generation synthetic femurs (Sawbones) with unstable intertrochanteric fractures were divided into 2 groups (n=6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA, Synthes) (n= 6) in the first group, and the Dynamic Hip Screw (DHS, Synthes) (n=6) in the second group. Both groups were subjected to bidirectional cyclic loading (600N compression loading, 120N tensile loading) at 2 Hz for 5000 cycles. The medial migration distance (MMD) was recorded at the end of the testing cycles. Results: The mean MMD in the PFNA group was 4.56mm (SD 0.69mm) with consistent reproduction of medial migration across all constructs tested. This was significantly more compared to the MMD of 1.17mm (SD 0.69mm) in the DHS group (p<0.001). Conclusion: Intramedullary nailing of unstable intertrochanteric hip fractures is inherently predisposed to FNE medial migration making it more susceptible to consequent cut-out compared to fixation with the DHS. (C) 2021 Published by Elsevier Ltd.
引用
收藏
页码:3440 / 3445
页数:6
相关论文
共 50 条
  • [41] External fixation of select intertrochanteric fractures with single hip screw
    Christodoulou, NA
    Sdrenias, CV
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2000, (381) : 204 - 211
  • [42] Fixation of intertrochanteric hip fractures: Gamma nail versus dynamic hip screw. A randomized, prospective study
    OBrien, PJ
    Meek, RN
    Blachut, PA
    Broekhuyse, HM
    Sabharwal, S
    CANADIAN JOURNAL OF SURGERY, 1995, 38 (06) : 516 - 520
  • [43] Minimally invasive dynamic hip screw for fixation of hip fractures
    Ho, Michael
    Garau, Giorgio
    Walley, Gayle
    Oliva, Francesco
    Panni, Alfredo Schiavone
    Longo, Umile Giuseppe
    Maffulli, Nicola
    INTERNATIONAL ORTHOPAEDICS, 2009, 33 (02) : 555 - 560
  • [44] Keyhole Sliding Hip Screw Fixation for Stable Intertrochanteric Hip Fractures: A Novel Technique
    Shivashankar, B.
    Shah, Sudhir
    Kumar, Gunasekaran
    Kumar, Sandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (06) : 1101 - 1107
  • [45] Keyhole Sliding Hip Screw Fixation for Stable Intertrochanteric Hip Fractures: A Novel Technique
    B. Shivashankar
    Sudhir Shah
    Gunasekaran Kumar
    Sandeep Kumar
    Indian Journal of Orthopaedics, 2022, 56 : 1101 - 1107
  • [46] Minimally invasive dynamic hip screw for fixation of hip fractures
    Michael Ho
    Giorgio Garau
    Gayle Walley
    Francesco Oliva
    Alfredo Schiavone Panni
    Umile Giuseppe Longo
    Nicola Maffulli
    International Orthopaedics, 2009, 33 : 555 - 560
  • [47] Gotfried Percutaneous Compression Plating Compared with Sliding Hip Screw Fixation of Intertrochanteric Hip Fractures A Prospective Randomized Study
    Yang, Edward
    Qureshi, Sheeraz
    Trokhan, Shawn
    Joseph, David
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (10): : 942 - 947
  • [48] Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
    Nicolas E. Efstathopoulos
    Vassilios S. Nikolaou
    John T. Lazarettos
    International Orthopaedics, 2007, 31 : 71 - 76
  • [49] Circumferential wires as a supplement to intramedullary nailing in unstable trochanteric hip fractures
    Akcay, Serkan
    Satoglu, Ismail Safa
    ACTA ORTHOPAEDICA, 2013, 84 (02) : 227 - 227
  • [50] Intramedullary fixation of intertrochanteric hip fractures: a comparison of two implant designs
    Efstathopoulos, Nicolas E.
    Nikolaou, Vassilios S.
    Lazarettos, John T.
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (01) : 71 - 76