Intramedullary nailing confers an increased risk of medial migration compared to dynamic hip screw fixation in unstable intertrochanteric hip fractures

被引:11
|
作者
Law, Gin Way [1 ]
Wong, Yoke Rung [2 ]
Gardner, Antony [3 ]
Ng, Yau Hong [1 ]
机构
[1] Natl Univ Hlth Syst, Singapore, Singapore
[2] Singapore Gen Hosp, Singapore, Singapore
[3] Ng Teng Feng Gen Hosp, Singapore, Singapore
关键词
Cephalomedullary nail; Intramedullary; PFNA; Sliding hip screw; Extramedullary; DHS; Medial migration; Cut-out; Toggling; PROXIMAL FEMORAL NAILS; GAMMA LOCKING NAIL; HELICAL BLADE; LAG SCREW; BIOMECHANICAL EVALUATION; TROCHANTERIC FRACTURES; INTERNAL-FIXATION; ADULTS YOUNGER; FAILURE; FEMUR;
D O I
10.1016/j.injury.2021.01.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: Medial migration of the femoral neck element (FNE) superomedially against gravity with respect to the intramedullary component of the cephalomedullary nail is a complication increasingly recognized to cause femoral head cut-out in intramedullary nailing of pertrochanteric hip fractures. Although cut-outs are common to both intra- and extramedullary fixation, especially in unstable pertrochanteric hip fractures, FNE medial migration in sliding hip screws continues to remain sparse despite increased awareness of the phenomenon. This study aims to investigate whether intramedullary nailing is biomechanically predisposed to FNE medial migration compared to extramedullary fixation with sliding hip screws to account for the discrepancy in reported FNE medial migration rates. Materials and methods: Twelve fourth-generation synthetic femurs (Sawbones) with unstable intertrochanteric fractures were divided into 2 groups (n=6 per group). Fracture fixation was performed using the Proximal Femoral Nail Antirotation (PFNA, Synthes) (n= 6) in the first group, and the Dynamic Hip Screw (DHS, Synthes) (n=6) in the second group. Both groups were subjected to bidirectional cyclic loading (600N compression loading, 120N tensile loading) at 2 Hz for 5000 cycles. The medial migration distance (MMD) was recorded at the end of the testing cycles. Results: The mean MMD in the PFNA group was 4.56mm (SD 0.69mm) with consistent reproduction of medial migration across all constructs tested. This was significantly more compared to the MMD of 1.17mm (SD 0.69mm) in the DHS group (p<0.001). Conclusion: Intramedullary nailing of unstable intertrochanteric hip fractures is inherently predisposed to FNE medial migration making it more susceptible to consequent cut-out compared to fixation with the DHS. (C) 2021 Published by Elsevier Ltd.
引用
收藏
页码:3440 / 3445
页数:6
相关论文
共 50 条
  • [31] Dynamic hip screw in the treatment of intertrochanteric fractures: a comparison of two fixation methods
    Lee, Yih-Shiunn
    Huang, Hui-Ling
    Lo, Ting-Ying
    Huang, Chien-Rae
    INTERNATIONAL ORTHOPAEDICS, 2007, 31 (05) : 683 - 688
  • [32] Intramedullary versus extramedullary fixation for the treatment of intertrochanteric hip fractures
    Baumgaertner, MR
    Curtin, SL
    Lindskog, DM
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (348) : 87 - 94
  • [33] GS Hip Nail versus Affixus Hip Fracture Nail for the Intramedullary Nailing of Intertrochanteric Fractures
    Kwon, Seungcheol
    Lee, Minjae
    Lee, Heeyeon
    Hwang, Jihyo
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (21)
  • [34] Dynamic hip screw versus intramedullary nailing for the treatment of A1 intertrochanteric fractures: A retrospective, comparative study and cost analysis
    Alessio-Mazzola, Mattia
    Traverso, Giacomo
    Coccarello, Francesco
    Sanguineti, Francesca
    Formica, Matteo
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (02): : 314 - 322
  • [35] Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study
    Kyriakopoulos, G.
    Panagopoulos, A.
    Pasiou, E.
    Kourkoulis, S. K.
    Diamantakos, I.
    Anastopoulos, G.
    Tserpes, K.
    Tatani, I.
    Lakoumentas, J.
    Megas, P.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2022, 53 (12): : 4072 - 4085
  • [36] The Gotfried percutaneous compression plate compared with the conventional classic hip screw for the fixation of intertrochanteric fractures of the hip - Reply
    Newman, RJ
    Kosygan, KP
    Mohan, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (01): : 149 - 149
  • [37] Functional and Radiological Outcome of Unstable Intertrochanteric Fracture Post Dynamic Hip Screw Fixation
    Lakho, Muhammad T.
    Jatoi, Asif A.
    Azfar, Muhammad Khanzada
    Ali, Aijaz
    Javed, Safiya
    Bhatti, Anisuddin
    Karim, Musa
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (04)
  • [38] Clinical Outcome Following Treatment of Stable and Unstable Intertrochanteric Fractures with Dynamic Hip Screw
    Setiobudi, Tony
    Ng, Yau Hong
    Lim, Chin Tat
    Liang, Shen
    Lee, Kevin
    Das De, Shamal
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2011, 40 (11) : 482 - 487
  • [39] Clinical Outcome Following Treatment of Stable and Unstable Intertrochanteric Fractures with Dynamic Hip Screw
    Haq, Rehan Ul
    Dhammi, Ish K.
    ANNALS ACADEMY OF MEDICINE SINGAPORE, 2012, 41 (06) : 275 - 276
  • [40] THE MANAGEMENT OF INTERTROCHANTERIC FRACTURES OF FEMUR BY DYNAMIC HIP SCREW
    Singh, Arvinder
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (74): : 15575 - 15579