Changes in corneal hysteresis after clear corneal cataract surgery

被引:81
作者
Hager, Annette [1 ]
Loge, Kristina
Fuellhas, Marc-Oliver
Schroeder, Ernd
Grossherr, Martin
Wiegand, Wolfgang
机构
[1] Asklepios Nord, Dept Ophthalmol, Hamburg, Germany
[2] Univ Schleswig Holstein, Dept Anesthesiol, Lubeck, Germany
关键词
D O I
10.1016/j.ajo.2007.05.023
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To assess the changes in corneal hysteresis (CH) as measured by the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, New York, USA) to describe the influence of clear corneal cataract surgery on corneal viscoelastic prop, erties and intraocular pressure (lop) measured by noncontact tonometry (NCT) and Goldmann applanation tonometry (GAT). DESIGN: Retrospective, interventional, comparative study. METHODS: One hundred and one eyes of 101 consec,utive patients who underwent routine clear corneal cataract surgery were evaluated. CH, NCT, and central corneal thickness (CCT) were measured by ORA before surgery and at postoperative day 1. A control group of 48 pseudophakic eyes (surgery > 3 months previously) was included. * RESULTS: CCT increased from 556.82 +/- 32.5 mu m before surgery to 580.26 +/- 45.5 mu m after surgery (P < .001; control, 555.16 +/- 42.33 mu m). Mean CH decreased from 10.35 +/- 2.5 mm Hg before surgery to 9.20 +/- 1.9 mm Hg after surgery (P < .001; control, 10.47 +/- 1.63 mm Hg). NCT values rose from 17.85 +/- 3.8 mm Hg before surgery to 20.10 +/- 6.3 mm Hg after surgery. GAT values were 14.85 +/- 2.8 mm Hg before surgery and 15.24 +/- 4.1 mm Hg after surgery (P = .52). There was no significant difference of CCT or CH between the preoperative values and the values of the control group (CCT, P = .986; CH, P = .166), in contrast to the difference between postoperative values and the values of the control group (CCT, P = .005; CH, P = .031). CONCLUSIONS: At day I after clear corneal cataract surgery, CH is diminished, whereas CCT is increased significantly. Postoperative corneal edema leads to a change of corneal viscoelastic properties, resulting in a lower damping capacity of the cornea. It is supposed that GAT and NCT measurements are significantly different because of postoperative changes in viscoelastic properties of the cornea.
引用
收藏
页码:341 / 346
页数:6
相关论文
共 26 条
[1]   Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) [J].
Brandt, JD ;
Beiser, JA ;
Kass, MA ;
Gordon, MO .
OPHTHALMOLOGY, 2001, 108 (10) :1779-1788
[2]   The influence of corneal thickness on the diagnosis and management of glaucoma [J].
Brandt, JD .
JOURNAL OF GLAUCOMA, 2001, 10 (05) :S65-S67
[3]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[4]   RELIABILITY OF INTRAOCULAR-PRESSURE MEASUREMENT WITH THE GOLDMANN APPLANATION TONOMETER IN EPIDEMIOLOGIC STUDIES [J].
DIELEMANS, I ;
VINGERLING, JR ;
HOFMAN, A ;
GROBBEE, DE ;
DEJONG, PTVM .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1994, 232 (03) :141-144
[5]  
DORNKE N, 2006, OPHTHALMOLOGE, V103, P583
[6]  
DRAEGER J, 1975, KLIN MONATSBL AUGENH, V167, P27
[7]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P652
[8]  
EHLERS N, 1975, ACTA OPHTHALMOL, V53, P34
[9]  
Falkenberg B, 2005, OPHTHALMOLOGE, V102, P587, DOI 10.1007/s00347-004-1135-9
[10]   Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings [J].
Feltgen, N ;
Leifert, D ;
Funk, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (01) :85-87