Sulfoalkylbetaine-based monolithic column with mixed-mode of hydrophilic interaction and strong anion-exchange stationary phase for capillary electrochromatography

被引:32
|
作者
Wang, Xiaochun [1 ]
Ding, Kang [1 ]
Yang, Chunmei [1 ]
Lin, Xucong [1 ]
Lue, Haixia [2 ]
Wu, Xiaoping [1 ]
Xie, Zenghong [1 ,3 ]
机构
[1] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Peoples R China
[2] Fuzhou Univ, Coll Mat Sci & Engn, Fuzhou 350108, Peoples R China
[3] Xiamen Huaxia Vocat Coll, Xiamen, Peoples R China
关键词
Hydrophilic interaction; Polar analytes; Pressurized CEC; Strong anion exchange; Sulfoalkylbetaine-based monolith; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLAR ANALYTES; RECENT PROGRESS; SILICA COLUMNS; SEPARATION; PEPTIDES; CEC; BEHAVIOR; ACIDS;
D O I
10.1002/elps.201000264
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel monolithic stationary phase with mixed mode of hydrophilic and strong anion exchange (SAX) interactions based on in situ copolymerization of pentaerythritol triacrylate (PETA), N,N-dimethyl-N-methacryloxyethyl N-(3-sulfopropyl) ammonium betaine (DMMSA) and a selected quaternary amine acrylic monomer was designed as a multifunctional separation column for CEC. Although the zwitterionic functionalities of DMMSA and hydroxy groups of PETA on the surface of the monolithic stationary phase functioned as the hydrophilic interaction (HI) sites, the quaternary amine acrylic monomer was introduced to control the magnitude of the EOF and provide the SAX sites at the same time. Three different quaternary amine acrylic monomers were tested to achieve maximum EOF velocity and highest plate count. The fabrication of the zwitterionic monolith (designated as HI and SAX stationary phase) was carried out when [2-(acryloyloxy) ethyl] trimethylammonium methylsulfate was used as the quaternary amine acrylic monomer. The separation mechanism of the monolithic column was discussed in detail. For charged analytes, a mixed mode of HI and SAX was observed by studying the influence of mobile phase pH and salt concentration on their retentions on the poly(PETA-co- DMMSA-co-[2-(acryloyloxy) ethyl] trimethylammonium methylsulfate) monolithic column. The optimized monolith showed good separation performance for a range of polar analytes including nucleotides, nucleic acid bases and nucleosides, phenols, estrogens and small peptides. The column efficiencies greater than 192 000 theoretical plates/m for estriol and 135 000 theoretical plates/m for charged cytidine were obtained.
引用
收藏
页码:2997 / 3005
页数:9
相关论文
共 50 条
  • [31] Rapid polymerization of polyhedral oligomeric siloxane-based zwitterionic sulfoalkylbetaine monolithic column in ionic liquid for hydrophilic interaction capillary electrochromatography
    Huang, Ting
    Zhang, Wanru
    Lei, Xiaoyun
    Chen, Huijuan
    Lin, Chenchen
    Wu, Xiaoping
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1659
  • [32] Investigation of the ion-exchange properties of methacrylate-based mixed-mode monolithic stationary phases employed as stationary phases in capillary electrochromatography
    Al-Rimawi, Fuad
    Pyell, Ute
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1160 (1-2) : 326 - 335
  • [33] Preparation and evaluation of a polymethacrylate based monolithic column for hydrophilic interaction capillary electrochromatography
    Huang Guihua
    Chen Sijin
    Lin Xucong
    Xie Zenghong
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2010, 28 (12) : 1173 - 1178
  • [34] A reversed phase/hydrophilic interaction/ion exchange mixed-mode stationary phase for liquid chromatography
    Sainan Zhang
    Feifang Zhang
    Bingcheng Yang
    Xinmiao Liang
    Chinese Chemical Letters, 2019, 30 (02) : 470 - 472
  • [35] A reversed phase/hydrophilic interaction/ion exchange mixed-mode stationary phase for liquid chromatography
    Zhang, Sainan
    Zhang, Feifang
    Yang, Bingcheng
    Liang, Xinmiao
    CHINESE CHEMICAL LETTERS, 2019, 30 (02) : 470 - 472
  • [36] A weak anion-exchange/reversed-phase mixed-mode HPLC column and its applications
    Liu, Xiaodong
    Pohl, Christopher
    AMERICAN LABORATORY, 2007, 39 (18) : 22 - +
  • [37] Separation of peptides on mixed mode of reversed-phase and ion-exchange capillary electrochromatography with a monolithic column
    Wu, RA
    Zou, HF
    Fu, HJ
    Jin, WH
    Ye, ML
    ELECTROPHORESIS, 2002, 23 (09) : 1239 - 1245
  • [38] Benzimidazole modified silica as a novel reversed-phase and anion-exchange mixed-mode stationary phase for HPLC
    Sun, Min
    Feng, Juanjuan
    Luo, Chuannan
    Liu, Xia
    Jiang, Shengxiang
    TALANTA, 2013, 105 : 135 - 141
  • [39] Glutathione-based zwitterionic stationary phase for hydrophilic interaction/cation-exchange mixed-mode chromatography
    Shen, Aijin
    Li, Xiuling
    Dong, Xuefang
    Wei, Jie
    Guo, Zhimou
    Liang, Xinmiao
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1314 : 63 - 69
  • [40] Investigation on the Retention and Separation of Glucosinolates With a Mixed-Mode Reversed-Phase/Weak Anion-Exchange Column
    Li, Yanfang
    Chen, Pei
    Zhang, Mengliang
    Sun, Jianghao
    JOURNAL OF SEPARATION SCIENCE, 2024, 47 (21)