Sulfoalkylbetaine-based monolithic column with mixed-mode of hydrophilic interaction and strong anion-exchange stationary phase for capillary electrochromatography

被引:32
|
作者
Wang, Xiaochun [1 ]
Ding, Kang [1 ]
Yang, Chunmei [1 ]
Lin, Xucong [1 ]
Lue, Haixia [2 ]
Wu, Xiaoping [1 ]
Xie, Zenghong [1 ,3 ]
机构
[1] Fuzhou Univ, Inst Food Safety & Environm Monitoring, Fuzhou 350108, Peoples R China
[2] Fuzhou Univ, Coll Mat Sci & Engn, Fuzhou 350108, Peoples R China
[3] Xiamen Huaxia Vocat Coll, Xiamen, Peoples R China
关键词
Hydrophilic interaction; Polar analytes; Pressurized CEC; Strong anion exchange; Sulfoalkylbetaine-based monolith; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLAR ANALYTES; RECENT PROGRESS; SILICA COLUMNS; SEPARATION; PEPTIDES; CEC; BEHAVIOR; ACIDS;
D O I
10.1002/elps.201000264
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel monolithic stationary phase with mixed mode of hydrophilic and strong anion exchange (SAX) interactions based on in situ copolymerization of pentaerythritol triacrylate (PETA), N,N-dimethyl-N-methacryloxyethyl N-(3-sulfopropyl) ammonium betaine (DMMSA) and a selected quaternary amine acrylic monomer was designed as a multifunctional separation column for CEC. Although the zwitterionic functionalities of DMMSA and hydroxy groups of PETA on the surface of the monolithic stationary phase functioned as the hydrophilic interaction (HI) sites, the quaternary amine acrylic monomer was introduced to control the magnitude of the EOF and provide the SAX sites at the same time. Three different quaternary amine acrylic monomers were tested to achieve maximum EOF velocity and highest plate count. The fabrication of the zwitterionic monolith (designated as HI and SAX stationary phase) was carried out when [2-(acryloyloxy) ethyl] trimethylammonium methylsulfate was used as the quaternary amine acrylic monomer. The separation mechanism of the monolithic column was discussed in detail. For charged analytes, a mixed mode of HI and SAX was observed by studying the influence of mobile phase pH and salt concentration on their retentions on the poly(PETA-co- DMMSA-co-[2-(acryloyloxy) ethyl] trimethylammonium methylsulfate) monolithic column. The optimized monolith showed good separation performance for a range of polar analytes including nucleotides, nucleic acid bases and nucleosides, phenols, estrogens and small peptides. The column efficiencies greater than 192 000 theoretical plates/m for estriol and 135 000 theoretical plates/m for charged cytidine were obtained.
引用
收藏
页码:2997 / 3005
页数:9
相关论文
共 50 条
  • [1] Monolithic silica columns with mixed mode of hydrophilic interaction and weak anion-exchange stationary phase for pressurized capillary electrochromatography
    Ye, Fanggui
    Xie, Zenghong
    Wong, Kwok-Yin
    ELECTROPHORESIS, 2006, 27 (17) : 3373 - 3380
  • [2] Preparation and characterization of hybrid-silica monolithic column with mixed-mode of hydrophilic and strong anion-exchange interactions for pressurized capillary electrochromatography
    Wang, Xiao
    Zheng, Yanqiong
    Zhang, Chunyuan
    Yang, Yanzhong
    Lin, Xucong
    Huang, Guihua
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1239 : 56 - 63
  • [3] Reversed-phase and weak anion-exchange mixed-mode silica-based monolithic column for capillary electrochromatography
    Ding, Guosheng
    Da, Zhenliang
    Yuan, Ruijuan
    Bao, James J.
    ELECTROPHORESIS, 2006, 27 (17) : 3363 - 3372
  • [4] Quinine-modified polymer monolithic column with reversed-phase /strong anion-exchange mixed-mode for pressurized capillary electrochromatography
    Wang, Jiabin
    Ding, Changying
    Xiao, Jianhua
    Jia, Wenchao
    Chen, Yongxuan
    Lin, Xucong
    Xie, Zenghong
    ELECTROPHORESIS, 2018, 39 (12) : 1504 - 1511
  • [5] Preparation of a mixed-mode hydrophilic interaction/anion-exchange polymeric monolithic stationary phase for capillary liquid chromatography of polar analytes
    Lin, Jian
    Lin, Jia
    Lin, Xucong
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (05) : 801 - 806
  • [6] A reversed-phase/hydrophilic bifunctional interaction mixed-mode monolithic column with biphenyl and quaternary ammonium stationary phases for capillary electrochromatography
    Mao, Zhenkun
    Hu, Changjun
    Li, Zhentao
    Chen, Zilin
    ANALYST, 2019, 144 (14) : 4386 - 4394
  • [7] Rapid capillary electrochromatographic profiling of phytohormones on a hydrophilic interaction/strong anion-exchange mixed-mode monolith
    Lin, Xucong
    Li, Yanping
    Xu, Dongjie
    Yang, Chunmei
    Xie, Zenghong
    ANALYST, 2013, 138 (02) : 635 - 641
  • [8] Open tubular columns with mixed-mode reversed-phase and weak anion-exchange stationary phase for capillary electrochromatography
    Lei, Jie
    Zhang, Xiangmin
    JOURNAL OF SEPARATION SCIENCE, 2013, 36 (12) : 1996 - 2002
  • [9] Capillary electrochromatography in anion-exchange and normal-phase mode using monolithic stationary phases
    Lämmerhofer, M
    Svec, F
    Fréchet, JMJ
    Lindner, W
    JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) : 265 - 277
  • [10] Novel highly hydrophilic methacrylate-based monolithic column with mixed-mode of hydrophilic and strong cation-exchange interactions for pressurized capillary electrochromatography
    Lin, Jia
    Liu, Shaofeng
    Lin, Jian
    Lin, Xucong
    Xie, Zenghong
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (29) : 4671 - 4677