Resorbable polylactic acid polymer plates in repair of blow-out orbital floor fractures

被引:8
作者
Esmail, Mohamed Esmail Khalil [1 ]
Ibrahiem, Mohamed Farag Khalil [1 ]
Abdallah, Raafat Mohyeldeen Abdelrahman [1 ]
Elshafei, Ahmed Mohamed Kamal [1 ]
Gawdat, Tamer Ismail [2 ]
机构
[1] Minia Univ, Minia Univ Hosp, Dept Ophthalmol, Korneesh El Nile St, Al Minya 61111, Egypt
[2] Cairo Univ, Dept Ophthalmol, Fac Med, Cairo, Egypt
关键词
Blow-out fracture; polylactic acid; resorbable implants; resorb X; RECONSTRUCTION; BIOMATERIALS; IMPLANTS;
D O I
10.1177/1120672120928005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the use of the resorbable polylactic acid polymer implants (Resorb X) in the management of orbital floor blow-out fractures as regards safety, cosmetic, and functional results. Methods: In a prospective, interventional case series, 22 patients with traumatic blow-out floor fractures underwent lower fornix transconjunctival repair using polylactic acid implant insertion over the defect without fixation. Orbital imaging was done preoperatively, at 1 month and 1 year postoperatively with orbital computed tomography with 2 mm cuts of axial, sagittal, and coronal scans. Outcome measures included the maximum vertical height of the orbit at the fracture plane and its changes over time. Results: At the final follow-up, both limitation of elevation and diplopia improved in 82% of cases, while 63.6% of cases showed improvement of enophthalmos. Radiological restoration of the orbital vertical height was recorded in 100% of cases without implant displacement at 1 month. However, after 1 year, a significant floor bowing was found in 45.5% of cases, which showed a strong positive correlation with preoperative defect size (r = 0.820). Conclusions: Resorb X mesh plates can be a good option for the safe reconstruction of orbital floor blow-out fractures. Good anatomical and functional results were obtained in small orbital floor defects. Late bowing under pressure may limit their use in medium-sized floor defects.
引用
收藏
页码:1384 / 1390
页数:7
相关论文
共 16 条
[1]  
CRAMER Lester M., 1965, BRIT J PLASTIC SURG, V18, P171, DOI 10.1016/S0007-1226(65)80022-4
[2]   Controversies in orbital reconstruction-III. Biomaterials for orbital reconstruction: a review with clinical recommendations [J].
Dubois, L. ;
Steenen, S. A. ;
Gooris, P. J. J. ;
Bos, R. R. M. ;
Becking, A. G. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (01) :41-50
[3]   A retrospective analysis of facial fracture etiologies [J].
Erdmann, Detlev ;
Follmar, Keith E. ;
DeBruijn, Marlieke ;
Bruno, Anthony D. ;
Jung, Sin-Ho ;
Edelman, David ;
Mukundan, Srinivasan ;
Marcus, Jeffrey R. .
ANNALS OF PLASTIC SURGERY, 2008, 60 (04) :398-403
[4]   Evidence-Based Medicine: Orbital Floor Fractures [J].
Gart, Michael S. ;
Gosain, Arun K. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (06) :1345-1355
[5]   Biomaterials for Repair of Orbital Floor Blowout Fractures: A Systematic Review [J].
Gunarajah, Dharmindra Rajah ;
Samman, Nabil .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (03) :550-570
[6]   THE ROLE OF ORBITAL WALL MORPHOLOGICAL PROPERTIES AND THEIR SUPPORTING STRUCTURES IN THE ETIOLOGY OF BLOW-OUT FRACTURES [J].
JO, A ;
RIZEN, V ;
NIKOLIC, V ;
BANOVIC, B .
SURGICAL AND RADIOLOGIC ANATOMY, 1989, 11 (03) :241-248
[7]  
Kuhn F, 2002, OCULAR TRAUMA PRINCI, P385
[8]   Repair of Orbital Floor Fractures Using Bioresorbable Poly-L/DL-Lactide Plates [J].
Lieger, Olivier ;
Schaller, Benoit ;
Zix, Juergen ;
Kellner, Frauke ;
Iizuka, Tateyuki .
ARCHIVES OF FACIAL PLASTIC SURGERY, 2010, 12 (06) :399-404
[9]   Porous polyethylene implants in orbital floor reconstruction [J].
Lin, I-Chan ;
Liao, Shu-Lang ;
Lin, Luke L. K. .
JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2007, 106 (01) :51-57
[10]   Use of Copolymer Polylactic and Polyglycolic Acid Resorbable Plates in Repair of Orbital Floor Fractures [J].
Lin, Jonathan ;
German, Michael ;
Wong, Brian .
FACIAL PLASTIC SURGERY, 2014, 30 (05) :581-586