The effect of zirconia and titanium implant abutments on light reflection of the supporting soft tissues

被引:129
|
作者
van Brakel, Ralph [1 ]
Noordmans, Herke Jan [2 ]
Frenken, Joost [3 ]
de Roode, Rowland [2 ]
de Wit, Gerard C. [5 ]
Cune, Marco S. [3 ,4 ]
机构
[1] Univ Med Ctr Utrecht, Dept Oral Maxillofacial Surg Prosthodont & Specia, NL-3508 AB Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Dept Med Technol, NL-3508 AB Utrecht, Netherlands
[3] St Antonius Hosp, Dept Oral Maxillofacial Surg Prosthodont & Specia, Nieuwegein, Netherlands
[4] Univ Groningen, Univ Med Ctr Groningen, Ctr Dent & Oral Hyg, Dept Fixed & Removable, NL-9713 AV Groningen, Netherlands
[5] Bartimeus, Zeist, Netherlands
关键词
aesthetics; implant; spectrophotometry; CONTROLLED CLINICAL-TRIAL; SINGLE-TOOTH IMPLANTS; CUSTOMIZED ZIRCONIA; OPTICAL PHENOMENON; CANCER-DETECTION; RESTORATIONS; GINGIVA; COLOR; RECONSTRUCTIONS; DISCOLORATION;
D O I
10.1111/j.1600-0501.2010.02082.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To determine the difference in light reflection of oral mucosa covering titanium (Ti) or zirconia (ZrO2) abutments as it relates to the thickness of the covering mucosa. Material and methods: Fifteen anterior implants (Astra Osseo speed (R)) in 11 patients were fitted with a Ti or a ZrO2 abutment (cross-over, within-subject comparison). Hyper-spectral images were taken with a camera fitted on a surgical microscope. High-resolution images with 70nm interval between 440 and 720 nm were obtained within 30 s (1392 x 1024 pixels). Black- and white-point reference was used for spatial and spectral normalization as well as correction for motion during exposure. Reflection spectra were extracted from the image on a line mid-buccal of the implant, starting 1mm above the soft tissue continuing up to 3mm apically. Results: Median soft tissue height is 2.3mm (min: 1.2mm and max: 3.1 mm). The buccal mucosa rapidly increases in the thickness, when moving apically. At 2.2mm, thickness is 3mm. No perceivable difference between the Ti and ZrO2 abutment can be observed when the thickness of the mucosa is 2 +/- 0.1mm (95% confidence interval) or more. Conclusion: It is expected that the difference in light reflection of soft tissue covering Ti or ZrO2 abutments is no longer noticeable for the human eye when the mucosa thickness exceeds 2mm. Haemoglobin peaks in the reflection spectrum can be observed and make hyper-spectral imaging a practical and useful tool for measuring soft tissue health.
引用
收藏
页码:1172 / 1178
页数:7
相关论文
共 50 条
  • [1] Comparison of the effect of zirconia and titanium abutments on peri-implant hard and soft tissues
    Luthra, Sahil
    Sirana, Pallavi
    Pasricha, Neeta
    Issar, Gaurav
    Singla, Neha
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2024, 24 (01): : 69 - 75
  • [2] Wear of the implant hexagon with Zirconia and Titanium abutments
    Barreto, M.
    Barbero, I.
    Forjaz, A.
    Martins, F.
    Pereira, J.
    Reis, L.
    Reis, J. A.
    Vaz, F.
    Mauricio, P.
    ANNALS OF MEDICINE, 2018, 50 : S68 - S69
  • [3] The integration of peri-implant soft tissues around zirconia abutments: Challenges and strategies
    Tang, Kai
    Luo, Meng-Lin
    Zhou, Wei
    Niu, Li-Na
    Chen, Ji-Hua
    Wang, Fu
    BIOACTIVE MATERIALS, 2023, 27 : 348 - 361
  • [4] Effect of titanium and zirconia dental implant abutments on a cultivable polymicrobial saliva community
    de Avila, Erica D.
    Vergani, Carlos Eduardo
    Mollo Junior, Francisco A.
    Jafelicci Junior, Miguel
    Shi, Wenyuan
    Lux, Renate
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (04): : 481 - 487
  • [5] Effect of titanium or zirconia implant abutments on epithelial attachments after ultrasonic cleaning
    Hu, Jiangqi
    Atsuta, Ikiru
    Ayukawa, Yasunori
    Zhou, Tianren
    Narimatsu, Ikue
    Koyano, Kiyoshi
    JOURNAL OF ORAL SCIENCE, 2020, 62 (03) : 331 - 334
  • [6] Soft tissue response to zirconia and titanium implant abutments: an in vivo within-subject comparison
    van Brakel, Ralph
    Meijer, Gert J.
    Verhoeven, Jan Willem
    Jansen, John
    de Putter, Cornelis
    Cune, Marco S.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2012, 39 (10) : 995 - 1001
  • [7] Bending moments of zirconia and titanium implant abutments supporting all-ceramic crowns after aging
    Muehlemann, Sven
    Truninger, Thomas C.
    Stawarczyk, Bogna
    Haemmerle, Christoph H. F.
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (01) : 74 - 81
  • [8] Load to failure of different zirconia implant abutments with titanium components
    Mascarenhas, Faye
    Yilmaz, Burak
    McGlumphy, Edwin
    Clelland, Nancy
    Seidt, Jeremy
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (06): : 749 - 754
  • [9] In Vitro Fatigue and Fracture Strength Testing of One-Piece Zirconia Implant Abutments and Zirconia Implant Abutments Connected to Titanium Cores
    Stimmelmayr, Michael
    Sagerer, Stefanie
    Erdelt, Kurt
    Beuer, Florian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (02) : 488 - 493
  • [10] Biological behavior of titanium, zirconia or PEEK dental implant-abutments
    Sordi, M. B.
    Sarwer-Foner, S. N. D.
    Schunemann, F. H.
    Apaza-Bedoya, K.
    Juanito, G. M. P.
    Henriques, B.
    Magini, R. S.
    Benfatti, C. A. M.
    BIODENTAL ENGINEERING V, 2019, : 31 - 42