Correlation between thromboelastography and rotational thromboelastometry values in adult liver transplant recipients

被引:1
作者
Singh, Shweta A. [1 ]
Krishnan, Gopi [1 ]
Ashraf, Hashir [1 ]
Subramanian, Rajkumar [1 ]
Pandey, Vijaykant [1 ]
Nasa, Vaibhav K. [1 ]
Goyal, Sumit [1 ]
Gupta, Subhash [1 ]
机构
[1] Max Super Special Hosp, Ctr Liver & Biliary Sci Anaesthesia & Crit Care, New Delhi, India
关键词
Rotational thromboelastometry; thromboelastography; viscoelastic haemostatic assays; BLOOD-TRANSFUSION; HYPOFIBRINOGENEMIA; THROMBOCYTOPENIA; COAGULOPATHY; MANAGEMENT; DISEASE; TRAUMA; POINT;
D O I
10.4103/ija.IJA_762_19
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and Aims: Viscoelastic haemostatic assays (VHA) namely Thromboelastogram (TEG) and Rotational thromboelastometry (ROTEM) are used for global assessment of coagulopathy and guiding transfusion during living donor liver transplant (LDLT).We conducted a study to compare the interchangeability of the values obtained from these devices in patients with End stage liver disease (ESLD) undergoing LDLT. Methods: In 76 patients undergoing LDLT, ROTEM and TEG were performed and assessed for interchangeability using Spearman Correlation. The direction and strength of correlation between equivalent parameters was calculated using Inter Class Correlation (ICC) and Bland Altman analysis. Results: The correlation rho between CT (clotting time) of ROTEM and R of TEG was 0.16 (P = 0.19).The ICC was 0.15, with 95% confidence interval (CI) of -0.38-0.48 (P = 0.25).The rho of CFT (ROTEM) with K (TEG) was 0.425 (P=<0.001).The ICC was0.49 with 95% CI of 0.17-0.69, P = 0.003.Alpha of ROTEM correlated with Angle of TEG with rho of 0.475 (P=<0.001). The ICC was 0.61, with 95% CI of 0.36-0.76, P=<0.001.Maximum Clot firmness (MCF) correlated with maximum amplitude (MA) with rho=0.76 (P=<0.001).The ICC was 0.86, with 95% CI of 0.77-0.92, P=<0.001. Lysis index (L30) of ROTEM correlated clot lysis (CL30) of TEG with rho & xfffd; of 0.16 (P = 0.18).However, the ICC was 0.45, with 95% CI of 0.11-0.66, P = 0.08.The correlation between CT of ROTEM and R of TEG as well as L30 of ROTEM and CL30 of TEG was not significant.The strongest correlation was found between MCF and MA (P < 0.001).However the MCF/MA showed an agreement of only 86% (ICC = 0.86). Conclusion: Values from ROTEM and TEG were not found to be interchangeable.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 20 条
  • [1] Transfusion and coagulation management in liver transplantation
    Clevenger, Ben
    Mallett, Susan V.
    [J]. WORLD JOURNAL OF GASTROENTEROLOGY, 2014, 20 (20) : 6146 - 6158
  • [2] Transfusion triggers in orthotopic liver transplantation: A comparison of the thromboelastometry analyzer, the thromboelastogram, and conventional coagulation tests
    Coakley, Margaret
    Reddy, Kalpana
    Mackie, Ian
    Mallett, Susan
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2006, 20 (04) : 548 - 553
  • [3] Effect of thromboelastography (TEG®) and rotational thromboelastometry (ROTEM®) on diagnosis of coagulopathy, transfusion guidance and mortality in trauma: descriptive systematic review
    Da Luz, Luis Teodoro
    Nascimento, Bartolomeu
    Shankarakutty, Ajith Kumar
    Rizoli, Sandro
    Adhikari, Neill K. J.
    [J]. CRITICAL CARE, 2014, 18 (05)
  • [4] Coagulation monitoring: Current techniques and clinical use of viscoelastic point-of-care coagulation devices
    Ganter, Michael T.
    Hofer, Christoph K.
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (05) : 1366 - 1375
  • [5] Evaluation of TEG® and RoTEM® inter-changeability in trauma patients
    Hagemo, Jostein S.
    Naess, Paal A.
    Johansson, Par
    Windelov, Nis A.
    Cohen, Mitchell Jay
    Roislien, Jo
    Brohi, Karim
    Heier, Hans Erik
    Hestnes, Morten
    Gaarder, Christine
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (05): : 600 - 605
  • [6] Coagulation monitoring devices: Past, present, and future at the point of care
    Harris, Leanne F.
    Castro-Lopez, Vanessa
    Killard, Anthony J.
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2013, 50 : 85 - 95
  • [7] The TEG® vs the ROTEM® thromboelastography/thromboelastometry systems
    Jackson, G. N. B.
    Ashpole, K. J.
    Yentis, S. M.
    [J]. ANAESTHESIA, 2009, 64 (02) : 212 - 215
  • [8] Quality Assurance and Quality Control of Thromboelastography and Rotational Thromboelastometry: The UK NEQAS for Blood Coagulation Experience
    Kitchen, Dianne P.
    Kitchen, Steve
    Jennings, Ian
    Woods, Tim
    Walker, Isobel
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2010, 36 (07) : 757 - 763
  • [9] Clinical Utility of Viscoelastic Tests of Coagulation (TEG/ROTEM) in Patients with Liver Disease and during Liver Transplantation
    Mallett, Susan V.
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2015, 41 (05) : 527 - 537
  • [10] In Trauma, Conventional ROTEM and TEG Results Are Not Interchangeable But Are Similar in Clinical Applicability
    Rizoli, Sandro
    Min, Arimie
    Sanchez, Adic Perez
    Shek, Pang
    Grodecki, Richard
    Veigas, Precilla
    Peng, Henry T.
    [J]. MILITARY MEDICINE, 2016, 181 (05) : 117 - 126