Optimal distributed energy resources and the cost of reduced greenhouse gas emissions in a large retail shopping centre

被引:44
作者
Braslavsky, Julio H. [1 ]
Wall, Josh R. [1 ]
Reedman, Luke J. [1 ]
机构
[1] CSIRO Energy Flagship, Newcastle, NSW 2300, Australia
关键词
Distributed energy resources; Greenhouse gas emissions reduction; Combined cooling heating and power (CCHP) systems; Energy efficiency; Economic modelling; SYSTEMS; STORAGE; BUILDINGS; OPERATION; CLIMATE;
D O I
10.1016/j.apenergy.2015.05.085
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a case study on optimal options for distributed energy resource (DER) technologies to reduce greenhouse gas emissions in a large retail shopping centre located in Sydney, Australia. Large retail shopping centres take the largest share of energy consumed by all commercial buildings, and present a strong case for adoption of DER technologies to reduce energy costs and emissions. However, the complexity of optimally designing and operating DER systems has hindered their widespread adoption in practice. This paper examines and demonstrates the value of DER in reducing the carbon footprint of the shopping centre by formulating and solving a multiobjective optimisation problem using the Distributed Energy Resources Customer Adoption Model (DER-CAM) tool. An economic model of the shopping centre is developed in DER-CAM using on-site-specific demand, tariffs, and performance data for each DER technology option available. Four key optimal DER technology investment scenarios are then analysed by comparing: (1) solution trade-offs of costs and emissions, (2) the cost of reduced emissions attained in each investment scenario, and (3) investment benefits with respect to the business-as-usual scenario. The analysis shows that a moderate investment in combined cooling, heat and power (CCHP) technology alone can reduce annual energy costs by 8.5% and carbon dioxide-equivalent emissions by 29.6%. A larger investment in CCHP technology, in conjunction with on-site solar photovoltaic (PV) generation, can deliver nearly 72% reductions in emissions at a 47% increase in total energy costs. The study demonstrates the effectiveness and flexibility of this type of modelling approach for the analysis, design, and ongoing assessment of new DER technologies under changing market conditions, supporting a more robust adoption of DER technologies in the commercial building sector. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:120 / 130
页数:11
相关论文
共 38 条
[1]  
ABARES, 2011, EN AUSTR
[2]  
ABS, 2014, EN ACC AUSTR EAA 201
[3]  
AEMO, 2011, DISTR LOSS FACT 2011
[4]  
AEMO, 2011, LIST REG BOUND MARG
[5]  
Alternative Technology Association, 2012, RENEW, P41
[6]  
[Anonymous], AUSTR SOL RAD DAT HD
[7]   Influence of the thermal energy storage on the profitability of micro-CHP systems for residential building applications [J].
Barbieri, Enrico Saverio ;
Melino, Francesco ;
Morini, Mirko .
APPLIED ENERGY, 2012, 97 :714-722
[8]  
ClimateWorks Australia, 2013, TRACK AUSTR PROGR 4
[9]   Optimal deployment of thermal energy storage under diverse economic and climate conditions [J].
DeForest, Nicholas ;
Mendes, Goncalo ;
Stadler, Michael ;
Feng, Wei ;
Lai, Judy ;
Marnay, Chris .
APPLIED ENERGY, 2014, 119 :488-496
[10]  
ESAA, 2011, EL GAS AUSTR 2011 EN