Use of the Ascent Balloon for a 2-in-1 Remodeling Technique: Feasibility and Initial Experience: Case Report

被引:14
作者
Clarencon, Frederic [1 ]
Perot, Guillaume [2 ]
Biondi, Alessandra [3 ]
Di Maria, Federico [1 ]
Szatmary, Zoltan [1 ]
Chiras, Jacques [1 ]
Sourour, Nader [1 ]
机构
[1] Univ Paris 06, Pitie Salpetriere Hosp, Dept Neuroradiol, Paris, France
[2] Univ Hosp Rouen, Dept Neuroradiol, Rouen, France
[3] Univ Hosp Besancon, Dept Neuroradiol, Besancon, France
关键词
Ascent; Balloon; Remodeling; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; COILING; SAFETY;
D O I
10.1227/NEU.0b013e31822c49ad
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND IMPORTANCE: To present the feasibility of using the Ascent balloon, a new double-lumen remodeling balloon, for a new 2-in-1 technique allowing coiling through the lumen of the balloon without the use of an additional coiling microcatheter. Remodeling technique had enlarged the indications for endovascular treatment of intracranial aneurysm. Nevertheless, one of the limitations of this technique is that it requires using 2 devices in the same parent artery. CLINICAL PRESENTATION: A 55-year-old woman presented with a 7.7 x 4.5-mm incidental anterior communicating artery aneurysm. Only 1 A1 segment (left side) was patent on the cerebral angiogram. A 6F Fargo Max guiding catheter was positioned in the left petrous internal carotid artery. The Ascent balloon was placed in front of the neck of the aneurysm after navigation on a Traxcess 0.014-in guidewire. Coiling of the aneurysm sac was performed via 1 lumen of the device under iterative inflations of the balloon through the second lumen. CONCLUSION: This new 2-in-1 technique using a sole remodeling balloon without an additional coiling microcatheter is very promising, especially in cases of a small-caliber parent artery.
引用
收藏
页码:170 / 173
页数:4
相关论文
共 6 条
[1]   Balloon-assisted Guglielmi detachable coiling of wide-necked aneurysms:: Part II -: Clinical results [J].
Lefkowitz, MA ;
Gobin, YP ;
Akiba, Y ;
Duckwiler, GR ;
Murayama, Y ;
Guglielmi, G ;
Martin, NA ;
Viñuela, F .
NEUROSURGERY, 1999, 45 (03) :531-537
[2]   Balloon-assisted coiling of intracranial aneurysms is not associated with a higher complication rate [J].
Lubicz, Boris ;
Lefranc, Florence ;
Bruneau, Michael ;
Baleriaux, Danielle ;
De Witte, Olivier .
NEURORADIOLOGY, 2008, 50 (09) :769-776
[3]  
Moret J, 1997, J NEURORADIOLOGY, V24, P30
[4]   Endovascular Treatment of Unruptured Intracranial Aneurysms: Comparison of Safety of Remodeling Technique and Standard Treatment with Coils [J].
Pierot, Laurent ;
Spelle, Laurent ;
Leclerc, Xavier ;
Cognard, Christophe ;
Bonafe, Alain ;
Moret, Jacques .
RADIOLOGY, 2009, 251 (03) :846-855
[5]   Safety and Efficacy of Adjunctive Balloon Remodeling during Endovascular Treatment of Intracranial Aneurysms: A Literature Review [J].
Shapiro, M. ;
Babb, J. ;
Becske, T. ;
Nelson, P. K. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (09) :1777-1781
[6]  
Sluzewski M, 2006, J NEUROSURG, V105, P396, DOI 10.3171/jns.2006.105.3.396