Frequency split metal artifact reduction (FSMAR) in computed tomography

被引:200
|
作者
Meyer, Esther [1 ]
Raupach, Rainer
Lell, Michael [3 ]
Schmidt, Bernhard [4 ]
Kachelriess, Marc [1 ,2 ]
机构
[1] Univ Erlangen Nurnberg, Inst Med Phys, D-91052 Erlangen, Germany
[2] German Canc Res Ctr, D-69120 Heidelberg, Germany
[3] Univ Erlangen Nurnberg, Inst Diagnost Radiol, D-91054 Erlangen, Germany
[4] Siemens Healthcare Forchheim, D-91301 Forchheim, Germany
关键词
metal artifacts; metal artifact reduction; metal implants; REFORMATTED PROJECTIONS; CT; SUPPRESSION; MULTISLICE; RECONSTRUCTION; ALGORITHM; SLICE; NMAR;
D O I
10.1118/1.3691902
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The problem of metal artifact reduction (MAR) is almost as old as the clinical use of computed tomography itself. When metal implants are present in the field of measurement, severe artifacts degrade the image quality and the diagnostic value of CT images. Up to now, no generally accepted solution to this issue has been found. In this work, a method based on a new MAR concept is presented: frequency split metal artifact reduction (FSMAR). It ensures efficient reduction of metal artifacts at high image quality with enhanced preservation of details close to metal implants. Methods: FSMAR combines a raw data inpainting-based MAR method with an image-based frequency split approach. Many typical methods for metal artifact reduction are inpainting-based MAR methods and simply replace unreliable parts of the projection data, for example, by linear interpolation. Frequency split approaches were used in CT, for example, by combining two reconstruction methods in order to reduce cone-beam artifacts. FSMAR combines the high frequencies of an uncorrected image, where all available data were used for the reconstruction with the more reliable low frequencies of an image which was corrected with an inpainting-based MAR method. The algorithm is tested in combination with normalized metal artifact reduction (NMAR) and with a standard inpainting-based MAR approach. NMAR is a more sophisticated inpainting-based MAR method, which introduces less new artifacts which may result from interpolation errors. A quantitative evaluation was performed using the examples of a simulation of the XCAT phantom and a scan of a spine phantom. Further evaluation includes patients with different types of metal implants: hip prostheses, dental fillings, neurocoil, and spine fixation, which were scanned with a modern clinical dual source CT scanner. Results: FSMAR ensures sharp edges and a preservation of anatomical details which is in many cases better than after applying an inpainting-based MAR method only. In contrast to other MAR methods, FSMAR yields images without the usual blurring close to implants. Conclusions: FSMAR should be used together with NMAR, a combination which ensures an accurate correction of both high and low frequencies. The algorithm is computationally inexpensive compared to iterative methods and methods with complex inpainting schemes. No parameters were chosen manually; it is ready for an application in clinical routine. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.3691902]
引用
收藏
页码:1904 / 1916
页数:13
相关论文
共 50 条
  • [21] Iterative metal artifact reduction for x-ray computed tomography using unmatched projector/backprojector pairs
    Zhang, Hanming
    Wang, Linyuan
    Li, Lei
    Cai, Ailong
    Hu, Guoen
    Yan, Bin
    MEDICAL PHYSICS, 2016, 43 (06) : 3019 - 3033
  • [22] Metal artifact reduction in computed tomography: Is it of benefit in evaluating sacroiliac joint fusion?
    Selles, M.
    Korte, J. H.
    Boelhouwers, H. J.
    Nijholt, I. M.
    van Osch, J. A. C.
    Nijveldt, R. J.
    Maas, M.
    Boomsma, M. F.
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 148
  • [23] Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
    Bamberg, Fabian
    Dierks, Alexander
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Becker, Christoph R.
    Johnson, Thorsten R. C.
    EUROPEAN RADIOLOGY, 2011, 21 (07) : 1424 - 1429
  • [24] Metal Artifact Reduction: Standard and Advanced Magnetic Resonance and Computed Tomography Techniques
    Gupta, Amit
    Subhas, Naveen
    Primak, Andrew N.
    Nittka, Mathias
    Liu, Kecheng
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2015, 53 (03) : 531 - +
  • [25] Iterative algorithms for artifact reduction in computed tomography
    Skornitzke, S.
    RADIOLOGE, 2018, 58 (03): : 202 - 210
  • [26] A novel noniterative metal artifact reduction method using coherence transport with fast marching in computed tomography
    Zhang, Yi
    Pu, Yi-Fei
    Zhang, Wei-Hua
    Hu, Jin-Rong
    Wang, Han
    Lei, Yin-Jie
    Zhou, Ji-Liu
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2012, 22 (04) : 200 - 207
  • [27] Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy
    Korpics, Mark
    Johnson, Paul
    Patel, Rakesh
    Surucu, Murat
    Choi, Mehee
    Emami, Bahman
    Roeske, John C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP88 - NP94
  • [28] Advancements in supervised deep learning for metal artifact reduction in computed tomography: A systematic review
    Kleber, Cecile E. J.
    Karius, Ramez
    Naessens, Lucas E.
    Van Toledo, Coen O.
    van Osch, Jochen A. C.
    Boomsma, Martijn F.
    Heemskerk, Jan W. T.
    van der Molen, Aart J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 181
  • [29] Model Image-Based Metal Artifact Reduction for Computed Tomography
    Dmytro Luzhbin
    Jay Wu
    Journal of Digital Imaging, 2020, 33 : 71 - 82
  • [30] Deep learning reconstruction with single-energy metal artifact reduction in pelvic computed tomography for patients with metal hip prostheses
    Hosoi, Reina
    Yasaka, Koichiro
    Mizuki, Masumi
    Yamaguchi, Haruomi
    Miyo, Rintaro
    Hamada, Akiyoshi
    Abe, Osamu
    JAPANESE JOURNAL OF RADIOLOGY, 2023, 41 (08) : 863 - 871