Clinical Determinants of Radiation Dose in Percutaneous Coronary Interventional Procedures

被引:88
作者
Fetterly, Kenneth A. [1 ]
Lennon, Ryan J. [2 ]
Bell, Malcolm R. [1 ]
Holmes, David R., Jr. [1 ]
Rihal, Charanjit S. [1 ]
机构
[1] Mayo Clin, Div Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN 55905 USA
关键词
percutaneous coronary intervention; physician influence on dose; radiation skin dose; AREA PRODUCT VALUES; ANGIOPLASTY PROCEDURES; CARDIAC PROCEDURES; ANGIOGRAPHY; EXPOSURE; CARDIOLOGY; TIME; RECONSTRUCTION; OCCLUSIONS; COMPLEXITY;
D O I
10.1016/j.jcin.2010.10.014
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives The objectives of this work were to establish the primary clinical determinants of patient radiation dose associated with percutaneous coronary interventional (PCI) and to identify opportunities for dose reduction. Background Use of X-ray imaging and associated radiation dose is a necessary part of PCI. Potential adverse consequences of radiation dose include skin radiation injury and predicted increase in lifetime cancer risk. Methods Cumulative skin dose (CSD) (measured in gray [Gy] units) was selected as a measurement of patient radiation burden. Several patient-, disease-, and treatment-related variables, including 15 performing physicians, were analyzed in a multiple linear regression statistical model with cumulative skin dose CSD as the primary end point. The model results provide an estimate of the relative CSD increase (decrease) attributable to each variable. Results Percutaneous coronary interventions performed on 1,287 male and 540 female patients were included. Median patient age was 68.6 years, median body mass index was 29.7 kg/m(2), and median weight was 88 kg. Median CSD was 1.64 Gy per procedure for male and 1.15 Gy for female patients. Increasing body mass index, patient sex, lesion complexity, lesion location, and performing physician were significantly associated with CSD. Physicians who performed more procedures were associated with lower CSD. Conclusions Several primary determinants of patient radiation dose during PCI were identified. Along with physician development of radiation-sparing methods and skills, pre-procedure dose planning is proposed to help minimize radiation dose for PCI. (J Am Coll Cardiol Intv 2011;4:336-43) (C) 2011 by the American College of Cardiology Foundation
引用
收藏
页码:336 / 343
页数:8
相关论文
共 38 条
[1]  
[Anonymous], 2000, 60601 IEC
[2]   BALLOON ANGIOPLASTY OF CHRONIC TOTAL CORONARY-ARTERY OCCLUSIONS - WHAT DOES IT COST IN RADIATION EXPOSURE, TIME, AND MATERIALS [J].
BELL, MR ;
BERGER, PB ;
MENKE, KK ;
HOLMES, DR .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1992, 25 (01) :10-15
[3]  
Bernardi G, 2000, CATHETER CARDIO INTE, V51, P1
[4]   A large-scale multicentre study in Belgium of dose area product values and effective doses in interventional cardiology using contemporary X-ray equipment [J].
Bogaert, E. ;
Bacher, K. ;
Thierens, H. .
RADIATION PROTECTION DOSIMETRY, 2008, 128 (03) :312-323
[5]   Patient doses and dosimetric evaluations in interventional cardiology [J].
Bor, Dogan ;
Olgar, Turan ;
Toklu, Tuerkay ;
Caglan, Ayca ;
Oenal, Elif ;
Padovani, Renato .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01) :31-42
[6]   Factors affecting patient radiation exposure during routine coronary angiography in a tertiary referral centre [J].
Clark, AL ;
Brennan, AG ;
Robertson, LJ ;
McArthur, JD .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866) :184-189
[7]   Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures [J].
Cusma, JT ;
Bell, MR ;
Wondrow, MA ;
Taubel, JP ;
Holmes, DR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) :427-435
[8]   Potential Irish dose reference levels for cardiac interventional examinations [J].
D'Helft, C. J. ;
Brennan, P. C. ;
Mcgee, A. M. ;
Mcfadden, S. L. ;
Hughes, C. M. ;
Winder, J. R. ;
Rainford, L. A. .
BRITISH JOURNAL OF RADIOLOGY, 2009, 82 (976) :296-302
[9]   Skin doses to patients undergoing coronary angiography in a Greek hospital [J].
Delichas, MG ;
Psarrakos, K ;
Giannoglou, G ;
Molyvda-Athanasopoulou, E ;
Hatziioannou, K ;
Papanastassiou, E .
RADIATION PROTECTION DOSIMETRY, 2005, 113 (04) :449-452
[10]  
Delichas MG, 2003, RADIAT PROT DOSIM, V103, P149, DOI 10.1093/oxfordjournals.rpd.a006126