A design-based model of the aortic valve for fluid-structure interaction

被引:17
|
作者
Kaiser, Alexander D. [1 ,2 ,3 ]
Shad, Rohan [3 ,4 ]
Hiesinger, William [3 ,4 ]
Marsden, Alison L. [1 ,2 ,3 ,5 ]
机构
[1] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Pediat Cardiol, Stanford, CA 94305 USA
[3] Stanford Cardiovasc Inst, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Cardiothorac Surg, Stanford, CA 94305 USA
[5] Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
基金
美国国家科学基金会;
关键词
Aortic valve; Aortic valve mechanics; Immersed boundary method; Aortic valve fluid-structure interaction; Aortic valve modeling; Heart valve modeling; BIAXIAL MECHANICAL-PROPERTIES; IMMERSED BOUNDARY MODEL; HEART-VALVE; PART I; DYNAMICS; CUSP; STRESS;
D O I
10.1007/s10237-021-01516-7
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper presents a new method for modeling the mechanics of the aortic valve and simulates its interaction with blood. As much as possible, the model construction is based on first principles, but such that the model is consistent with experimental observations. We require that tension in the leaflets must support a pressure, then derive a system of partial differential equations governing its mechanical equilibrium. The solution to these differential equations is referred to as the predicted loaded configuration; it includes the loaded leaflet geometry, fiber orientations and tensions needed to support the prescribed load. From this configuration, we derive a reference configuration and constitutive law. In fluid-structure interaction simulations with the immersed boundary method, the model seals reliably under physiological pressures and opens freely over multiple cardiac cycles. Further, model closure is robust to extreme hypo- and hypertensive pressures. Then, exploiting the unique features of this model construction, we conduct experiments on reference configurations, constitutive laws and gross morphology. These experiments suggest the following conclusions: (1) The loaded geometry, tensions and tangent moduli primarily determine model function. (2) Alterations to the reference configuration have little effect if the predicted loaded configuration is identical. (3) The leaflets must have sufficiently nonlinear material response to function over a variety of pressures. (4) Valve performance is highly sensitive to free edge length and leaflet height. These conclusions suggest appropriate gross morphology and material properties for the design of prosthetic aortic valves. In future studies, our aortic valve modeling framework can be used with patient-specific models of vascular or cardiac flow.
引用
收藏
页码:2413 / 2435
页数:23
相关论文
共 50 条
  • [1] A design-based model of the aortic valve for fluid-structure interaction
    Alexander D. Kaiser
    Rohan Shad
    William Hiesinger
    Alison L. Marsden
    Biomechanics and Modeling in Mechanobiology, 2021, 20 : 2413 - 2435
  • [2] Fluid-structure interaction of a pulsatile flow with an aortic valve model: A combined experimental and numerical study
    Siguenza, Julien
    Pott, Desiree
    Mendez, Simon
    Sonntag, Simon J.
    Kaufmann, Tim A. S.
    Steinseifer, Ulrich
    Nicoud, Franck
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2018, 34 (04)
  • [3] A fluid-structure interaction model of the aortic valve with coaptation and compliant aortic root
    Marom, Gil
    Haj-Ali, Rami
    Raanani, Ehud
    Schaefers, Hans-Joachim
    Rosenfeld, Moshe
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2012, 50 (02) : 173 - 182
  • [4] Fluid-structure interaction simulation of calcified aortic valve stenosis
    Cai, Li
    Hao, Yu
    Ma, Pengfei
    Zhu, Guangyu
    Luo, Xiaoyu
    Gao, Hao
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2022, 19 (12) : 13172 - 13192
  • [5] Validation and Extension of a Fluid-Structure Interaction Model of the Healthy Aortic Valve
    Tango, Anna Maria
    Salmonsmith, Jacob
    Ducci, Andrea
    Burriesci, Gaetano
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2018, 9 (04) : 739 - 751
  • [6] Fluid-Structure Interaction methods for the progressive anatomical and artificial aortic valve stenosis
    Nowak, Marcin
    Divo, Eduardo
    Adamczyk, Wojciech P.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2022, 227
  • [7] A computational study of the three-dimensional fluid-structure interaction of aortic valve
    Chen, Ye
    Luo, Haoxiang
    JOURNAL OF FLUIDS AND STRUCTURES, 2018, 80 : 332 - 349
  • [8] Computational Modeling of Aortic Stenosis With a Reduced Degree-of-Freedom Fluid-Structure Interaction Valve Model
    Zhu, Chi
    Seo, Jung-Hee
    Mittal, Rajat
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2022, 144 (03):
  • [9] An approach to the simulation of fluid-structure interaction in the aortic valve
    Carmody, CJ
    Burriesci, G
    Howard, IC
    Patterson, EA
    JOURNAL OF BIOMECHANICS, 2006, 39 (01) : 158 - 169
  • [10] Fluid-structure interaction of deformable aortic prostheses with a bileaflet mechanical valve
    de Tullio, M. D.
    Afferrante, L.
    Demelio, G.
    Pascazio, G.
    Verzicco, R.
    JOURNAL OF BIOMECHANICS, 2011, 44 (09) : 1684 - 1690