Development of a Smart Seat Cushion for Heart Rate Monitoring Using Ballistocardiography

被引:3
作者
Malik, Ahmed R. [1 ]
Pilon, Laurel [1 ]
Boger, Jennifer [1 ,2 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON, Canada
[2] Res Inst Aging, Waterloo, ON, Canada
来源
2019 22ND IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE AND ENGINEERING (IEEE CSE 2019) AND 17TH IEEE INTERNATIONAL CONFERENCE ON EMBEDDED AND UBIQUITOUS COMPUTING (IEEE EUC 2019) | 2019年
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/CSE/EUC.2019.00078
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
For many individuals with cardiac conditions, long term monitoring of heart vitals is an essential part of ongoing care. Current monitoring technologies, such as wearables and medical devices, though accurate, are obtrusive, require the person to remember to use them, and need to be used correctly. Wearable monitors are, therefore, not ideal for everyone. This research developed a prototype portable seat cushion that can capture heart rate using a cardiovascular signal called the ballistocardiogram (BCG) by a person simply sitting on the cushion. The cushion uses load cells embedded inside it as well as analog and digital signal conditioning to obtain BCG, which is then processed to calculate heart rate. Results from nine participants sitting still show that the cushion is able to obtain an average accuracy of 95.1%, which is as good as or better than other similar methods reported in the literature. To the authors' knowledge, this work represents the first portable ambient device for measuring heart rate from a seated position. The smart seat cushion can easily be integrated into an Ambient Assisted Living (AAL) system and offers a zero-effort and unobtrusive alternative to wearable monitoring devices.
引用
收藏
页码:379 / 383
页数:5
相关论文
共 23 条
[1]  
Armanfard N, 2018, IEEE ENG MED BIO, P4444, DOI 10.1109/EMBC.2018.8513326
[2]   Remote Monitoring of Patients With Heart Failure: An Overview of Systematic Reviews [J].
Bashi, Nazli ;
Karunanithi, Mohanraj ;
Fatehi, Farhad ;
Ding, Hang ;
Walters, Darren .
JOURNAL OF MEDICAL INTERNET RESEARCH, 2017, 19 (01)
[3]  
Boger J., 2018, SYNTHESIS LECT ASSIS
[4]  
Chang I.S. J., 2018, Gerontechnology, V17, P77
[5]   Non-contact home health monitoring based on low-cost high-performance accelerometers [J].
Feng, Xiaoce ;
Xu, Yong ;
Dong, Ming ;
Levy, Philip .
2017 IEEE/ACM SECOND INTERNATIONAL CONFERENCE ON CONNECTED HEALTH - APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2017, :356-364
[6]   Towards the standardization of ballistocardiography systems for J-peak timing measurement [J].
Gomez-Clapers, Joan ;
Serra-Rocamora, Albert ;
Casanella, Ramon ;
Pallas-Areny, Ramon .
MEASUREMENT, 2014, 58 :310-316
[7]  
Heise D, 2013, IEEE IMTC P, P397
[8]   Robust ballistocardiogram acquisition for home monitoring [J].
Inan, O. T. ;
Etemadi, M. ;
Wiard, R. M. ;
Giovangrandi, L. ;
Kovacs, G. T. A. .
PHYSIOLOGICAL MEASUREMENT, 2009, 30 (02) :169-185
[9]  
Junnila Sakari, 2006, Conf Proc IEEE Eng Med Biol Soc, V2006, P5932
[10]   Wireless biomedical signal monitoring device on wheelchair using noncontact electro-mechanical film sensor [J].
Kim, Jong-Myoung ;
Hong, Joo-Hyun ;
Cho, Myeong-Chan ;
Cha, Eun-Jong ;
Lee, Tae-Soo .
2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, :574-+