Application of calixarene ionophores in PVC based ISEs for uranium detection

被引:35
作者
Duncan, DM [1 ]
Cockayne, JS [1 ]
机构
[1] AWE, Reading RG7 4PR, Berks, England
关键词
uranium; uranyl ion; calix[4]arene; ion-selective electrodes; sensor;
D O I
10.1016/S0925-4005(00)00693-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A lower rim functionalised calixarene molecule 5,11,17,23-tetra-tert-butyl-25,27-bis(hydroxy)-26-(ethoxycarbonylmethoxy)-28-(diethyl carbamoyl-methoxy) calix[4]arene, which was originally developed for solid phase extraction of trace uranium from environmental and industrial waste water, is tested as a possible ionophore in ion selective electrodes (ISEs). PVC based membranes containing the calix[4]arene were used in experiments to test the characteristics and viability of these sensors. The electrodes gave more stable potential readings when used around neutral pH 5.5-8.5. Extraction experiments using the PVC membranes showed that the calix[4]arene complexed with:the uranyl species end extracted it from the test solutions most effectively at around pH 7.0. The limit of detection for uranium species, around 1 ppm under normal conditions, was avoided by preconditioning the membranes at high pH. The effect of testing for uranium selectivity amongst a matrix of cations and anions in a simulated waste solution showed that interference was significant. As we are at the beginning of this research, suggestions for further work on these electrodes are made in light of recent reports of work in this field. (C) 2001 Published by Elsevier Science B.V.
引用
收藏
页码:228 / 235
页数:8
相关论文
共 31 条
[1]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[2]   Neutral lanthanide di- and mono-meric complexes and selective extraction properties of a new 1,3-acid-diethyl amide substituted calix[4]arene ligand [J].
Beer, PD ;
Drew, MGB ;
Grieve, A ;
Kan, M ;
Leeson, PB ;
Nicholson, G ;
Ogden, MI ;
Williams, G .
CHEMICAL COMMUNICATIONS, 1996, (10) :1117-1118
[3]   A neutral uranyl dimeric complex and remarkable extraction properties of a 1-acid 3-diethyl amide substituted calix[4]arene ligand [J].
Beer, PD ;
Drew, MGB ;
Hesek, D ;
Kan, M ;
Nicholson, G ;
Schmitt, P ;
Sheen, PD ;
Williams, G .
JOURNAL OF THE CHEMICAL SOCIETY-DALTON TRANSACTIONS, 1998, (17) :2783-2785
[4]  
Cao Z, 1998, CHEM J CHINESE U, V19, P882
[5]   Electrochemistry of calixarene and its analytical applications [J].
Chung, TD ;
Kim, H .
JOURNAL OF INCLUSION PHENOMENA AND MOLECULAR RECOGNITION IN CHEMISTRY, 1998, 32 (2-3) :179-193
[6]   Calixarene monolayers as quartz crystal microbalance sensing elements in aqueous solution [J].
Cygan, MT ;
Collins, GE ;
Dunbar, TD ;
Allara, DL ;
Gibbs, CG ;
Gutsche, CD .
ANALYTICAL CHEMISTRY, 1999, 71 (01) :142-148
[7]   INVIVO SENSORS [J].
DIAMOND, D ;
SVEHLA, G .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1987, 6 (02) :46-49
[8]  
Diamond D, 1996, CHEM SOC REV, V25, P15, DOI 10.1039/cs9962500015
[9]  
DIAMOND D, 1986, ANAL CHEM S SERIES, V25, P155
[10]  
*FLUK CHEM AG, 1996, SEL ION MEMBR MIN IS