Diagnostic Accuracy of Real-Time Tissue Elastography for the Staging of Liver Fibrosis: A Meta-Analysis

被引:42
作者
Kobayashi, Kunio [1 ]
Nakao, Haruhisa [1 ]
Nishiyama, Takeshi [2 ]
Lin, Yingsong [2 ]
Kikuchi, Shogo [2 ]
Kobayashi, Yuji [1 ]
Yamamoto, Takaya [1 ]
Ishii, Norimitsu [1 ]
Ohashi, Tomohiko [1 ]
Satoh, Ken [1 ]
Nakade, Yukiomi [1 ]
Ito, Kiyoaki [1 ]
Yoneda, Masashi [1 ]
机构
[1] Aichi Med Univ, Sch Med, Dept Internal Med, Div Gastroenterol, Nagakute, Aichi 4801195, Japan
[2] Aichi Med Univ, Sch Med, Dept Publ Hlth, Nagakute, Aichi 4801195, Japan
关键词
Liver fibrosis; Liver stiffness; Real-time tissue elastography (RTE); Meta-analysis; Summary Receiver Operating Characteristic Curve (SROC); CHRONIC HEPATITIS-C; SHEAR-WAVE ELASTOGRAPHY; TRANSIENT ELASTOGRAPHY; NONINVASIVE ASSESSMENT; SAMPLING VARIABILITY; PERFORMANCE; STIFFNESS; BIOPSY; TECHNOLOGY; QUALITY;
D O I
10.1007/s00330-014-3364-x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To evaluate the overall accuracy of real-time tissue elastography (RTE) for the staging of liver fibrosis. Methods We systematically reviewed 15 studies (1,626 subjects) in which sensitivity and specificity of RTE for liver fibrosis are available. For each cut-off stage of fibrosis, i.e., F >= 1, F >= 2, F >= 3, and F >= 4, summary sensitivity and specificity were estimated using a bivariate random-effects model. Publication bias was assessed using funnel plots and Egger's test. Results Summary sensitivity and specificity were 0.79 and 0.76 for F >= 2, 0.82 and 0.81 for F >= 3, and 0.74 and 0.84 for F >= 4, respectively. Meta-regressions revealed scoring methods of RTE and liver diseases in the samples might not influence sensitivity and specificity of RTE. However, the estimated accuracy of RTE might be overestimated due to publication bias (p=0.004 for F >= 2, p< 0.001 for F >= 3, and p=0.002 for F >= 4). Conclusions RTE is not highly accurate for any cut-off stage of fibrosis. Compared with findings of meta-analyses on Transient Elastography and Acoustic Radiation Force Impulse imaging, the overall accuracy of RTE seems to be nearly identical for the evaluation of significant liver fibrosis, but less accurate for the evaluation of cirrhosis.
引用
收藏
页码:230 / 238
页数:9
相关论文
共 52 条
  • [1] [Anonymous], METAANALYSIS DIAGNOS
  • [2] Acute viral hepatitis increases liver stiffness values measured by transient elastography
    Arena, Umberto
    Vizzutti, Francesco
    Corti, Giampaolo
    Ambu, Silvia
    Stasi, Cristina
    Bresci, Silvia
    Moscarella, Stefania
    Boddi, Vied
    Petrarca, Antonio
    Laffi, Giacomo
    Marra, Fabio
    Pinzani, Massimo
    [J]. HEPATOLOGY, 2008, 47 (02) : 380 - 384
  • [3] NONINVASIVE IN VIVO LIVER FIBROSIS EVALUATION USING SUPERSONIC SHEAR IMAGING: A CLINICAL STUDY ON 113 HEPATITIS C VIRUS PATIENTS
    Bavu, Eric
    Gennisson, Jean-Luc
    Couade, Mathieu
    Bercoff, Jeremy
    Mallet, Vincent
    Fink, Mathias
    Badel, Anne
    Vallet-Pichard, Anais
    Nalpas, Bertrand
    Tanter, Mickael
    Pol, Stanislas
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09) : 1361 - 1373
  • [4] Sampling variability of liver fibrosis in chronic hepatitis C
    Bedossa, P
    Dargère, D
    Paradis, V
    [J]. HEPATOLOGY, 2003, 38 (06) : 1449 - 1457
  • [5] Natural history of compensated viral cirrhosis:: a prospective study on the incidence and hierarchy of major complications
    Benvegnù, L
    Gios, M
    Boccato, S
    Alberti, A
    [J]. GUT, 2004, 53 (05) : 744 - 749
  • [6] Meta-analysis: ARFI elastography versus transient elastography for the evaluation of liver fibrosis
    Bota, Simona
    Herkner, Harald
    Sporea, Ioan
    Salzl, Petra
    Sirli, Roxana
    Neghina, Adriana M.
    Peck-Radosavljevic, Markus
    [J]. LIVER INTERNATIONAL, 2013, 33 (08) : 1138 - 1147
  • [7] Current concepts: Liver biopsy.
    Bravo, AA
    Sheth, SG
    Chopra, S
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2001, 344 (07) : 495 - 500
  • [8] Prospective comparison of transient elastography, fibrotest, APRI, and liver biopsy for the assessment of fibrosis in chronic hepatitis C
    Castéra, L
    Vergniol, J
    Foucher, J
    Le Bail, B
    Chanteloup, E
    Haaser, M
    Darriet, M
    Couzigou, P
    De Lédinghen, V
    [J]. GASTROENTEROLOGY, 2005, 128 (02) : 343 - 350
  • [9] A systematic review of the quality of liver biopsy specimens
    Cholongitas, E
    Senzolo, M
    Standish, R
    Marelli, L
    Quaglia, A
    Patch, D
    Dhillon, AP
    Burroughs, AK
    [J]. AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 125 (05) : 710 - 721
  • [10] The usefulness of transient elastography, acoustic-radiation-force impulse elastography, and real-time elastography for the evaluation of liver fibrosis
    Chung, Jong Ho
    Ahn, Hyung Su
    Kim, Sang Gyune
    Lee, Yun Nah
    Kim, Young Seok
    Jeong, Soung Won
    Jang, Jae Young
    Lee, Sae Hwan
    Kim, Hong Soo
    Kim, Boo Sung
    [J]. CLINICAL AND MOLECULAR HEPATOLOGY, 2013, 19 (02) : 156 - 164