A new polyvinylchloride-based membrane of rubeanic acid as an ion carrier was fabricated using oleic acid as lipophilic additive. The best performance was exhibited by the membrane having composition rubeanic acid:PVC:OA:o-NPOE as 5:180:18:208 (w/w). The sensor exhibited a Nernstian response for La3+ over a wide concentration range of 3.2 x 10(-8) to 1.0 x 10(-2) M with a detection limit of 2.5 x 10(-8) M. It showed response time of less than 15 s and could be used for 5 months without any significant divergence. The proposed membrane sensor revealed good selectivity for La3+ over a wide variety of other metal ions and can be used in a pH range of 3.5-9.5 and in mixtures containing up to 30% (v/v) non-aqueous content. It was successfully used as an indicator electrode in the potentiometric titration of La(III) against EDTA. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 40 条
[1]   METAL-COMPLEXES OF RUBEANIC ACID .3. LARGE-ANGLE X-RAY-SCATTERING STUDIES OF AMORPHOUS COPPER(II) AND NICKEL(II) COMPLEXES [J].
ABBOUDI, M ;
MOSSET, A ;
GALY, J .
INORGANIC CHEMISTRY, 1985, 24 (13) :2091-2094
[2]   Lanthanum-selective membrane electrode based on 2,2′-dithiodipyridine [J].
Akhond, M ;
Najafi, MB ;
Tashkhourian, J .
ANALYTICA CHIMICA ACTA, 2005, 531 (02) :179-184
[3]  
Amarchand S, 2000, ELECTROANAL, V12, P522, DOI 10.1002/(SICI)1521-4109(200005)12:7<522::AID-ELAN522>3.0.CO
[4]  
2-D
[5]   PREPARATION OF NEUTRAL IONOPHORES FOR ALKALI AND ALKALINE-EARTH METAL CATIONS AND THEIR APPLICATION IN ION-SELECTIVE MEMBRANE ELECTRODES [J].
AMMANN, D ;
BISSIG, R ;
GUGGI, M ;
PRETSCH, E ;
SIMON, W ;
BOROWITZ, IJ ;
WEISS, L .
HELVETICA CHIMICA ACTA, 1975, 58 (06) :1535-1548
[6]  
ANGHILERI LJ, 1987, ANTICANCER RES, V7, P1205
[7]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[8]  
BAILER JC, 1973, COMPREHENSIVE INORGA, V4
[9]  
Berenzani J., 1971, J RADIOANAL CHEM, V9, P81
[10]   RECOMMENDATIONS FOR NOMENCLATURE OF ION-SELECTIVE ELECTRODES - (IUPAC RECOMMENDATIONS 1994) [J].
BUCK, RP ;
LINDNER, E .
PURE AND APPLIED CHEMISTRY, 1994, 66 (12) :2527-2536