Development of a lateral flow strip biosensor based on copper oxide nanoparticles for rapid and sensitive detection of HPV16 DNA

被引:43
|
作者
Yang, Zheng [2 ]
Yi, Chun [1 ,2 ]
Lv, Sijia [2 ]
Sheng, Yuhao [2 ]
Wen, Wei [2 ]
Zhang, Xiuhua [2 ]
Wang, Shengfu [1 ,2 ]
机构
[1] Hubei Univ, Hubei Collaborat Innovat Ctr Adv Organ Chem Mat, Minist Educ, Key Lab Synth & Applicat Organ Funct Mol, Wuhan 430062, Peoples R China
[2] Hubei Univ, Coll Chem & Chem Engn, Wuhan 430062, Peoples R China
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2019年 / 285卷
基金
中国国家自然科学基金;
关键词
Lateral flow strip biosensor; Copper oxide nanoparticle; Human papillomavirus 16 DNA; HUMAN-PAPILLOMAVIRUS; VISUAL DETECTION; CUO; AMPLIFICATION; CANCER; IMMUNOASSAY; SENSOR;
D O I
10.1016/j.snb.2019.01.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Human papillomavirus (HPV) type 16 is widely distributed in population, which is responsible for more than 50% of cervical cancers. A point-of-care testing for HPV16 is critical for early diagnosis and decisions regarding patient care. In this work, a novel lateral flow strip biosensor (LFSB) has been established by a simple, low-cost and green synthetic procedure for the detection of HPV16 DNA. Copper oxide nanoparticles (CuO NPs) were used as colored tags in the LFSB for the first time. In a typical experimental procedure, CuO NPs were sequentially functionalized with streptavidin and biotinylated capture DNA to form the CuO Capture probes. In the present of HPV16 DNA, the CuO Capture probes would capture the target, forming a characteristic brown band due to the second base pairing with the test DNA probes on the test zone of LFSB, which enabling the visual detection. A portable strips reader achieved the quantitative detection. The optimized CuO-based LFSB was capable of detecting the target over its concentration ranged from 5 nM to 100 nM with a limit of detection of 1.0 nM, and the whole detection process could be completed within 20 min. The CuO-based LFSB shows a great promise and versatile opportunities in point-of-care diagnosis of genetic diseases with good reproducibility and stability.
引用
收藏
页码:326 / 332
页数:7
相关论文
共 50 条
  • [1] A high fidelity CRISPR/Cas12a based lateral flow biosensor for the detection of HPV16 and HPV18
    Mukama, Omar
    Yuan, Ting
    He, Zhixu
    Li, Zhiyuan
    Habimana, Jean de Dieu
    Hussain, Muzammal
    Li, Wei
    Yi, Zhijian
    Liang, Qiongxin
    Zeng, Lingwen
    SENSORS AND ACTUATORS B-CHEMICAL, 2020, 316
  • [2] Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA
    Zhang, Donghong
    Liu, Dongliang
    Liu, Bing
    Ma, Xiulan
    JOURNAL OF MICROBIOLOGY AND BIOTECHNOLOGY, 2021, 31 (04) : 610 - 620
  • [3] Carbon nanotube-based lateral flow biosensor for sensitive and rapid detection of DNA sequence
    Qiu, Wanwei
    Xu, Hui
    Takalkar, Sunitha
    Gurung, Anant S.
    Liu, Bin
    Zheng, Yafeng
    Guo, Zebin
    Baloda, Meenu
    Baryeh, Kwaku
    Liu, Guodong
    BIOSENSORS & BIOELECTRONICS, 2015, 64 : 367 - 372
  • [4] AuPt nanoalloy with dual functionalities for sensitive detection of HPV16 DNA
    Yu, Qingcai
    Qian, Lisheng
    Qiu, Wanwei
    Miao, Yongmei
    Zhang, Jing
    Wang, Yan
    RSC ADVANCES, 2023, 13 (20) : 13940 - 13946
  • [5] Rapid immunoassay for dual-mode detection of HPV16 and HPV18 DNA based on Au@PdPt nanoparticles
    Xiao, Huanxin
    Chen, Weiguang
    Lin, Mingxia
    Jiang, Shilin
    Cui, Xiping
    Zhao, Suqing
    ANALYTICAL METHODS, 2024, 16 (13) : 1862 - 1869
  • [6] Rapid and sensitive detection of β-agonists using a portable fluorescence biosensor based on fluorescent nanosilica and a lateral flow test strip
    Song, Chunmei
    Zhi, Aimin
    Liu, Qingtang
    Yang, Jifei
    Jia, Guochao
    Shervin, Jahanian
    Tang, Liang
    Hu, Xiaofei
    Deng, Ruiguang
    Xu, Chuanlai
    Zhang, Gaiping
    BIOSENSORS & BIOELECTRONICS, 2013, 50 : 62 - 65
  • [7] Development of Rapid Detection Technology for HPV16 Based on CRISPR-Cas12a
    Tian, Xingzhong
    Yi, Yuan Xue
    Xu, Jian
    Luo, Zeqin
    Xing, Na
    Wang, Zhengbing
    Chen, Sini
    Ye, Xin
    Shen, Youliang
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2022, 36 (05): : 1661 - 1668
  • [8] Rapid and Sensitive Detection of Protein Biomarker Using a Portable Fluorescence Biosensor Based on Quantum Dots and a Lateral Flow Test Strip
    Li, Zhaohui
    Wang, Ying
    Wang, Jun
    Tang, Zhiwen
    Pounds, Joel G.
    Lin, Yuehe
    ANALYTICAL CHEMISTRY, 2010, 82 (16) : 7008 - 7014
  • [9] A portable fluorescence biosensor for rapid and sensitive glutathione detection by using quantum dots-based lateral flow test strip
    Liu, Juanzu
    Ji, Danyang
    Meng, Hongmin
    Zhang, Lin
    Wang, Junyan
    Huang, Zhongming
    Chen, Juan
    Li, Jianjun
    Li, Zhaohui
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 262 : 486 - 492
  • [10] MWCNTs based high sensitive lateral flow strip biosensor for rapid determination of aqueous mercury ions
    Yao, Li
    Teng, Jun
    Zhu, Mengya
    Zheng, Lei
    Zhong, Youhao
    Liu, Guodong
    Xue, Feng
    Chen, Wei
    BIOSENSORS & BIOELECTRONICS, 2016, 85 : 331 - 336