Stability, marginal bone loss and survival of standard and modified sand-blasted, acid-etched implants in bilateral edentulous spaces: a prospective 15-month evaluation

被引:46
作者
Karabuda, Zihni Cuneyt [1 ]
Abdel-Haq, Jawad [1 ,2 ]
Arisan, Volkan [1 ]
机构
[1] Istanbul Univ, Dept Oral Implantol, Fac Dent, TR-34093 Istanbul, Turkey
[2] Int Univ Sci & Technol, Damascus, Syria
关键词
bone-level changes; dental implants; early loading; implant survival; marginal bone loss; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; TITANIUM DENTAL IMPLANTS; PROSPECTIVE MULTICENTER; SURFACE CHARACTERISTICS; STRAUMANN IMPLANTS; GROWTH-HORMONE; SLA SURFACE; IN-VIVO; MAXILLA; DOG;
D O I
10.1111/j.1600-0501.2010.02065.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Chemical modification of the already proven sand-blasted and acid-etched (SLA) implant had increased its surface wettability and consequent early-term osseointegration characteristics. The aim of this clinical trial was to compare the stability changes, success, survival, peri-implant parameters and marginal bone loss (MBL) of the early-loaded standard (SLA) and modified sand-blasted, acid-etched (modSLA) implants. Material and methods: A total of 96 SLA and modSLA implants were placed in a bi-lateral, cross-arch position to the jaws of 22 patients. Resonance frequency analysis (RFA) was used to measure the implant stability in the surgery and following healing after 1, 3 and 6 weeks. At the stage of loading, a panoramic X-ray was obtained and RFA measurement was repeated for all implants. Implants were restored by metal-ceramic crowns and followed for 1 year to determine the success, survival rate, peri-implant parameters and MBL. Results were compared by one-and two-way ANOVA, log-rank test and generalized linear mixed models (P<0.05). Results: One modSLA implant was lost after 3 weeks following the surgery yielding to a 100 and 97.91% success rate for SLA and modSLA implants, respectively (P = 0.323). At the loading stage, modSLA implants showed significantly lower MBL (0.18 +/- 0.05 mm) than SLA implants (0.22 +/- 0.06 mm; P = 0.002). In the loading stage, RFA value of the modSLA implants (60.42 +/- 6.82) was significantly higher than the both implant types in the surgical stage (55.46 +/- 8.29 and 56.68 +/- 8.19), and following 1 (56.08 +/- 7.01 and 55.60 +/- 9.07) and 3 weeks of healing (55.94 +/- 5.95 and 55.40 +/- 6.50 for SLA and modSLA implants, respectively). Conclusions: modSLA implants demonstrated a better stability and a reduced MBL at the loading stage. Both SLA and modSLA implants demonstrated a favorable success and survival at the end of 15-month follow-up.
引用
收藏
页码:840 / 849
页数:10
相关论文
共 64 条
[1]   Osseointegration and stability of a modified sand-blasted acid-etched implant: an experimental pilot study in sheep [J].
Abdel-Haq, Jawad ;
Karabuda, Cuneyt Z. ;
Arisan, Volkan ;
Mutlu, Zihni ;
Kurkcu, Mehmet .
CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (03) :265-274
[2]   Early bone formation adjacent to rough and turned endosseous implant surfaces - An experimental study in the dog [J].
Abrahamsson, I ;
Berglundh, T ;
Linder, E ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2004, 15 (04) :381-392
[3]   Implant stability in relation to osseointegration: an experimental study in the Labrador dog [J].
Abrahamsson, Ingemar ;
Linder, Elena ;
Lang, Niklaus P. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (03) :313-318
[4]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[5]   Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™):: system configuration and physical properties [J].
Araki, K ;
Maki, K ;
Seki, K ;
Sakamaki, K ;
Harata, Y ;
Sakaino, R ;
Okano, T ;
Seo, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (01) :51-59
[6]   Evaluation of 316 narrow diameter implants followed for 5-10 years: a clinical and radiographic retrospective study [J].
Arisan, Volkan ;
Bolukbasi, Nilufer ;
Ersanli, Selim ;
Ozdemir, Tayfun .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) :296-307
[7]   Early loading of mandibular full-arch bridges screw retained after 1 week to four to five Monotype® implants:: 3-year results from a prospective multicentre study [J].
Arvidson, Kristina ;
Esselin, Ove ;
Felle-Persson, Ewa ;
Jonsson, Goran ;
Smedberg, Jan-Ivan ;
Soderstrom, Ulf .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (07) :693-703
[8]  
Bergkvist G, 2010, INT J ORAL MAX IMPL, V25, P321
[9]   Bone apposition around two different sandblasted and acid-etched titanium implant surfaces: a histomorphometric study in canine mandibles [J].
Bornstein, Michael M. ;
Valderrama, Pilar ;
Jones, Archie A. ;
Wilson, Thomas G. ;
Seibl, Reinhart ;
Cochran, David L. .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (03) :233-241