Preoperative evaluation of live renal donors using multislice CT angiography

被引:22
作者
Johnson, JE
Loveday, EJ [1 ]
Archer, LJ
Lear, P
Thornton, MJ
机构
[1] Southmead Gen Hosp, N Bristol NHS Trust, Dept Radiol, Bristol BS10 5NB, Avon, England
[2] Southmead Gen Hosp, Dept Surg, Bristol BS10 5NB, Avon, England
关键词
computed tomography (CT); renal angiography; kidney transplantation;
D O I
10.1016/j.crad.2004.12.007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To determine the accuracy of multidetector row CT renal angiography in the preoperative evaluation of live kidney donors, and to identify potential pitfalls when reporting. METHODS: Between July 1998 and June 2003, 74 consecutive live renal donors underwent contrast-enhanced multidetector row CT renal angiography before donor nephrectomy. The operative notes and radiological reports of all cases were reviewed retrospectively. Where a significant discrepancy was identified, the archived images were reviewed by two radiologists in the light of the intraoperative findings. RESULTS: A total of 12 discrepancies were identified in 11 of the 74 cases (15%). In the preoperative CT angiography reports, 4 accessory arteries, 6 early-branching renal arteries, 1 duplicated renal vein and 1 accessory ureter were not identified; 9 of these were evident on review, but were not detected at the time of reporting. In 3 cases (1 accessory artery, the duplicated renal vein and the accessory ureter), the anomaly was not visible on review of the CT angiographic data, even with the benefit of hindsight. Surgical feedback during the study period resulted in modifications to CT technique and improved performance. CONCLUSION: In the majority of cases, there was good correlation between preoperative CT renal angiography and operative findings. Most discrepancies were due either to an oversight by the reporting radiologist or failure to fully appreciate the potential surgical significance of certain findings. Regular surgical feedback plays a valuable role in improving reporting accuracy and maintaining imaging standards. (c) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All. rights reserved.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 50 条
  • [21] Evaluation of renal arteries in living renal donors: Comparison between MDCT angiography and gadolinium-enhanced 3D MR angiography
    Kim T.
    Murakami T.
    Takahashi S.
    Hori M.
    Takahara S.
    Ichimaru N.
    Okuyama A.
    Narumi Y.
    Nakamura H.
    Radiation Medicine, 2006, 24 (9): : 617 - 624
  • [22] Potential renal transplant donors: Evaluation with gadolinium-enhanced MR angiography and MR urography
    Low, RN
    Martinez, AG
    Steinberg, SM
    Alzate, GD
    Kortman, KE
    Bower, BB
    Dwyer, WJ
    Prince, SK
    RADIOLOGY, 1998, 207 (01) : 165 - 172
  • [23] Femoral artery occlusion after blunt trauma: Diagnosis by multislice CT angiography
    Chen J.K.
    Johnson P.T.
    Fishman E.K.
    Emergency Radiology, 2006, 12 (5) : 244 - 245
  • [24] Potential renal donors: Comparison of conventional imaging with helical CT
    Platt, JF
    Ellis, JH
    Korobkin, M
    Reige, KA
    Konnak, JW
    Leichtman, AB
    RADIOLOGY, 1996, 198 (02) : 419 - 423
  • [25] Application value of multislice spiral computed tomography angiography in the evaluation of renal artery variation in living donor kidney transplantation
    Zhao, X. Y.
    Tian, J.
    Ru, Y. H.
    Sun, B.
    Sun, C. F.
    Zhang, A. M.
    Shao, Y. H.
    GENETICS AND MOLECULAR RESEARCH, 2015, 14 (01) : 314 - 322
  • [26] Evaluation and selection of potential live kidney donors
    Wafa, EW
    Donia, AF
    Ali-El-Dein, B
    El Agroudy, AE
    Rifaie, A
    Moustafa, A
    Ghoneim, MA
    JOURNAL OF UROLOGY, 2004, 171 (04) : 1424 - 1427
  • [27] ASSESSMENT OF LIVING RENAL DONORS WITH SPIRAL CT
    RUBIN, GD
    ALFREY, EJ
    DAKE, MD
    SEMBA, CP
    SOMMER, FG
    KUO, PC
    DAFOE, DC
    WASKERWITZ, JA
    BLOCH, DA
    JEFFREY, RB
    RADIOLOGY, 1995, 195 (02) : 457 - 462
  • [28] Ureteropelvic junction obstruction:: Use of helical CT for preoperative assessment -: Comparison with intraarterial angiography
    Rouvière, O
    Lyonnet, D
    Berger, P
    Pangaud, C
    Gelet, A
    Martin, X
    RADIOLOGY, 1999, 213 (03) : 668 - 673
  • [29] Assessment of live kidney donors by magnetic resonance angiography: reliability and impact on outcomes
    Monroy-Cuadros, Mauricio
    McLaughlin, Kevin
    Salazar, Anastasio
    Yilmaz, Serdar
    CLINICAL TRANSPLANTATION, 2008, 22 (01) : 29 - 34
  • [30] Renal artery evaluation: Comparison of spiral CT angiography to intra-arterial DSA
    Kim, TS
    Chung, JW
    Park, JH
    Kim, SH
    Yeon, KM
    Han, MC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (04) : 553 - 559