Diffuse pollution loading from urban stormwater runoff in Daejeon city, Korea

被引:82
作者
Kim, Geonha
Yur, Joonghyun
Kim, Jeongkon
机构
[1] Hannam Univ, Dept Civil & Environm Engn, Taejon 300791, South Korea
[2] Korea Water Resources Corp, Korea Inst Water & Environm, Taejon 305730, South Korea
关键词
diffuse pollution; stormwater runoff; combined sewer overflow (CSO); urban stream; detention basin;
D O I
10.1016/j.jenvman.2006.07.009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, stormwater runoff from an urban watershed with combined sewer systems located in Daejeon metropolitan city, Korea, was characterized to measure the stormwater runoff discharge rates and pollutant concentrations. The observed averaged event mean concentrations (EMCs) of combined sewer overflows (CSO) were 536.1 mg TSS/L, 467.7 mg TCODcr/L, 142.7 mg TBOD/L, 16.5 mg TN/L, and 13.5 mg TP/L. A detention basin was proposed to reduce CSO, and its essential design elements were discussed. The first flush significantly affected contaminant constituents in the descending order of suspended solid > organics > nutrients. Storage volumes for containing the first flush to improve water quality of the receiving strearn can be estimated based on the total suspended solid loading. In this study, detention of the first flush equivalent to 5 turn of precipitation could reduce CSO-induced diffuse pollution loading to a receiving water body by up to 80% of the total suspended solid loading. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9 / 16
页数:8