Quantitative OCT-based corneal topography in keratoconus with intracorneal ring segments

被引:30
作者
Ortiz, Sergio [1 ]
Perez-Merino, Pablo [1 ]
Alejandre, Nicolas [2 ]
Gambra, E. [1 ]
Jimenez-Alfaro, I. [2 ]
Marcos, Susana [1 ]
机构
[1] CSIC, Inst Opt Daza de Valdes, Madrid 28006, Spain
[2] Fdn Jimenez Diaz, E-28040 Madrid, Spain
来源
BIOMEDICAL OPTICS EXPRESS | 2012年 / 3卷 / 05期
关键词
OPTICAL COHERENCE TOMOGRAPHY; PENETRATING KERATOPLASTY; ANTERIOR SEGMENT; PACHYMETRY; THICKNESS; EYES; VIDEOKERATOGRAPHY; REPEATABILITY; ABERRATIONS; ULTRASOUND;
D O I
10.1364/BOE.3.000814
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Custom high-resolution high-speed anterior segment spectral domain Optical Coherence Tomography (OCT) was used to characterize three-dimensionally (3-D) corneal topography in keratoconus before and after implantation of intracorneal ring segments (ICRS). Previously described acquisition protocols were followed to minimize the impact of the motions of the eye. The collected set of images was corrected from distortions: fan (scanning) and optical (refraction). Custom algorithms were developed for automatic detection and classification of volumes in the anterior segment of the eye, in particular for the detection and classification of the implanted ICRS. Surfaces were automatically detected for quantitative analysis of the corneal elevation maps (fitted by biconicoids and Zernike polynomials) and pachymetry. Automatic tools were developed for the estimation of the 3-D positioning of the ICRS. The pupil center reference was estimated from the segmented iris volume. The developed algorithms are illustrated in a keratoconic eye (grade III) pre- and 30 days post-operatively after implantation of two triangular-section, 0.3-mm thick Ferrara ring segments. Quantitative corneal topographies reveal that the ICRS produced a flattening of the anterior surface, a steepening of the posterior surface, meridional differences in the changes in curvature and asphericity, and increased symmetry of the anterior topography. Optical distortion correction through the ICRS (of a different refractive index from the cornea) allowed accurate pachymetric estimates, which showed increased thickness in the ectatic area as well as in peripheral corneal areas. Automatic tools allowed estimation of the depth of the implanted ICRS ring, as well as its rotation with respect to the pupil plane. Anterior segment sOCT provided with fan and optical distortion correction and analysis tools is an excellent instrument for evaluating and monitoring keratoconic eyes and for the quantification of the changes produced by ICRS treatment. (c) 2012 Optical Society of America
引用
收藏
页码:814 / 825
页数:12
相关论文
共 42 条
  • [1] Intracorneal rings to correct corneal ectasia after laser in situ keratomileusis
    Alió, L
    Salem, TF
    Artola, A
    Osman, AA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) : 1568 - 1574
  • [2] Barbero S, 2002, J REFRACT SURG, V18, P263
  • [3] Barraquer J I, 1966, Int Ophthalmol Clin, V6, P53, DOI 10.1097/00004397-196606010-00004
  • [4] BLAVATSK.ED, 1968, ARCH SOC AM OFTALMOL, V6, P311
  • [5] Burris T E, 1998, Curr Opin Ophthalmol, V9, P9, DOI 10.1097/00055735-199808000-00003
  • [6] FLATTENING OF CENTRAL CORNEAL CURVATURE WITH INTRASTROMAL CORNEAL RINGS OF INCREASING THICKNESS - AN EYE-BANK EYE STUDY
    BURRIS, TE
    BAKER, PC
    AYER, CT
    LOOMAS, BE
    MATHIS, ML
    SILVESTRINI, TA
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 : 182 - 187
  • [7] Correcting keratoconus with intracorneal rings
    Colin, J
    Cochener, B
    Savary, G
    Malet, F
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) : 1117 - 1122
  • [8] Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus
    Dauwe, Caroline
    Touboul, David
    Roberts, Cynthia J.
    Mahmoud, Ashraf M.
    Kerautret, Julien
    Fournier, Pierre
    Malecaze, Francois
    Colin, Joseph
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (10) : 1761 - 1767
  • [9] Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry
    De Sanctis, Ugo
    Missolungi, Alessandro
    Mutani, Bernardo
    Richiardi, Lorenzo
    Grignolo, Federico M.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) : 712 - 718
  • [10] Anterior segment imaging with Spectral OCT system using a high-speed CMOS camera
    Grulkowski, Ireneusz
    Gora, Michalina
    Szkulmowski, Maciej
    Gorczynska, Iwona
    Szlag, Daniel
    Marcos, Susana
    Kowalczyk, Andrzej
    Wojtkowski, Maciej
    [J]. OPTICS EXPRESS, 2009, 17 (06): : 4842 - 4858