Improving the standard of the standard for glass ionomers: An alternative to the compressive fracture strength test for consideration?

被引:25
作者
Dowling, Adam H. [1 ]
Fleming, Garry J. P. [1 ]
McGinley, Emma L. [1 ]
Addison, Owen [2 ]
机构
[1] Trinity Coll Dublin, Dublin Dent Univ Hosp, Div Oral Biosci, Mat Sci Unit, Dublin 2, Ireland
[2] Univ Birmingham, Biomat Unit, Sch Dent, Birmingham B4 6NN, W Midlands, England
关键词
Glass ionomer restorative; ISO 9917-1: 2003; Compressive fracture strength; Three point flexure strength; Biaxial flexure strength; Validity; Reliability; CLINICALLY INDUCED VARIABILITY; PHOSPHATE DENTAL CEMENT; AXIAL FLEXURE STRENGTH; TENSILE-STRENGTH; BRITTLE MATERIALS; COMPOSITES; FAILURE; RATIO; FLUOROAPATITE; RESTORATIVES;
D O I
10.1016/j.jdent.2011.12.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Three strength tests (compressive, three point flexure and biaxial) were performed on three glass ionomer (GI) restoratives to assess the most appropriate methodology in terms of validity and reliability. The influence of mixing induced variability on the data sets generated were eliminated by using encapsulated GIs. Methods: Specimen groups of 40 (eight batches of n = 5) cylinders (6.0 +/- 0.1 mm height, 4.0 +/- 0.1 mm diameter) for compressive fracture testing, bars (25.0 +/- 0.1 mm length, 2.0 +/- 0.1 mm height, 2.0 +/- 0.1 mm width) for three point flexure testing and discs (13.0 +/- 0.1 mm diameter, 1.0 +/- 0.1 mm thickness) for biaxial flexure testing were randomly prepared by an operator. The strength data sets for each GI restorative were pooled and one-way analyses of variance (ANOVAs) were conducted to compare between GI restoratives (p = 0.05). The coefficient of variation (CoV) values for each test were pooled and a one-way ANOVA was conducted to test for differences between the reliability of the three tests. Results: For the GI restoratives, the one-way ANOVA showed significant differences when tested in compression (p = 0.001) but not when tested in three point (p = 0.271) or biaxial (p = 0.134) flexure. The pooled CoV values showed no significant difference between the three strength tests (p = 0.632). Conclusions: The compressive fracture strength test specified for GIs in the International Organisation for Standardisation (ISO 9917-1: 2003) should be replaced and should no longer be advocated for the predictive performance modelling of GI restoratives. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:189 / 201
页数:13
相关论文
共 41 条
[31]   Modification of conventional glass-ionomer cements with N-vinylpyrrolidone containing polyacids, nano-hydroxy and fluoroapatite to improve mechanical properties [J].
Moshaverinia, Alireza ;
Ansari, Sahar ;
Movasaghi, Zanyar ;
Billington, Richard W. ;
Darr, Jawwad A. ;
Rehman, Ihtesham U. .
DENTAL MATERIALS, 2008, 24 (10) :1381-1390
[32]   Effects of incorporation of hydroxyapatite and fluoroapatite nanobioceramics into conventional glass ionomer cements (GIC) [J].
Moshaverinia, Alireza ;
Ansari, Sahar ;
Moshaverinia, Maryam ;
Roohpour, Nima ;
Darr, Jawwad A. ;
Rehman, Ihtesham .
ACTA BIOMATERIALIA, 2008, 4 (02) :432-440
[33]   The reliability of standardized flexure strength testing procedures for a light-activated resin-based composite [J].
Palin, WM ;
Fleming, GJP ;
Marquis, PM .
DENTAL MATERIALS, 2005, 21 (10) :911-919
[34]   The reliability in flexural strength testing of a novel dental composite [J].
Palin, WM ;
Fleming, GJP ;
Burke, JFT ;
Marquis, PM ;
Randall, RC .
JOURNAL OF DENTISTRY, 2003, 31 (08) :549-557
[35]  
Peltier R, 1954, UNION TESTING RES LA, V19, P29
[36]   Universal behaviour in compressive failure of brittle materials [J].
Renshaw, CE ;
Schulson, EM .
NATURE, 2001, 412 (6850) :897-900
[37]   CRITIQUE OF TEST METHODS FOR LIFETIME PREDICTIONS [J].
RITTER, JE .
DENTAL MATERIALS, 1995, 11 (02) :147-151
[38]  
TIMOSHENKO S, 1959, THEORY PLATES SHELLS, P87
[39]   The effect of the disc support system on biaxial tensile strength of a glass ionomer cement [J].
Williams, JA ;
Billington, RW ;
Pearson, GJ .
DENTAL MATERIALS, 2002, 18 (05) :376-379
[40]  
Wilson AD, 1975, SCI ASPECTS DENT MAT, P131