Voltammetric Determination of Uric Acid in Clinical Serum Samples Using DMF Modified Screen Printed Carbon Electrodes

被引:17
作者
Metto, Melaku [1 ]
Eramias, Samrawit [1 ]
Gelagay, Bekele [1 ]
Washe, Alemayehu P. [1 ]
机构
[1] Hawassa Univ, Dept Chem, POB 05, Hawassa, Ethiopia
关键词
ASCORBIC-ACID; BIOSENSOR;
D O I
10.1155/2019/6318515
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Screen printed carbon electrodes (SPCEs) provide attractive opportunity for sensitive and selective determination target analytes in clinical samples. The aim of the current work was to develop SPCEs based sensor for the determination of uric acid in clinical serum samples. The electrodes were pretreated by soaking in N,N-dimethylformamide for 5 minutes followed by drying in an oven at 100 degrees C for 20 mins. The effect of surface pretreatment was characterized using cyclic voltammetry. The current response of uric acid detection was improved by a factor of 3.5 in differential pulse voltammetric measurement compared to unmodified electrode. Under the optimized conditions, the sensor displayed two dynamic linear ranges 5-100 M and 100-500 M with correlation coefficient, R-2, values of 0.98782 and 0.97876, respectively. The limit of detection and limit of quantification calculated using the dynamic linear range 5-100 M were 1.9 x 10(-7) M and 6.33 x 10(-7) M, respectively. The developed sensor displayed well separated and discerned peaks for UA in presence of the potential interferent (ascorbic acid and citric acid). The electrode was successfully applied for the detection of very low level of UA in clinical serum samples in a phosphate buffer solution (pH = 7). The proposed sensor showed a very high reproducibility and repeatability with the relative standard deviation of 0.9%. In conclusion, a simple and low cost sensor based on SPCEs is developed for sensitive and selective detection of uric acid in clinical samples.
引用
收藏
页数:8
相关论文
共 23 条
[1]  
Ali K., 2015, INT J PURE APPL CHEM, V1, P43
[2]   Subfemtomolar determination of alkaline phosphatase at a disposable screen-printed electrode modified with a perfluorosulfonated ionomer film [J].
Bagel, O ;
Limoges, B ;
Schollhorn, B ;
Degrand, C .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4688-4694
[3]   Adsorption: an easy and efficient immobilisation of acetylcholinesterase on screen-printed electrodes [J].
Bonnet, C ;
Andreescu, S ;
Marty, JL .
ANALYTICA CHIMICA ACTA, 2003, 481 (02) :209-211
[4]   Disposable amperometric immunosensor system for rabbit IgG using a conducting polymer modified screen-printed electrode [J].
Darain, F ;
Park, SU ;
Shim, YB .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) :773-780
[5]   Screen printing of nucleic acid detecting carbon electrodes [J].
Dequaire, M ;
Heller, A .
ANALYTICAL CHEMISTRY, 2002, 74 (17) :4370-4377
[6]   Rapid identification of viable Escherichia coli subspecies with an electrochemical screen-printed biosensor array [J].
Ertl, P ;
Wagner, M ;
Corton, E ;
Mikkelsen, SR .
BIOSENSORS & BIOELECTRONICS, 2003, 18 (07) :907-916
[7]   Electrochemical characterization of screen-printed and conventional carbon paste electrodes [J].
Fanjul-Bolado, Pablo ;
Hernandez-Santos, David ;
Lamas-Ardisana, Pedro Jos ;
Martin-Pernia, Alberto ;
Costa-Garcia, Agustin .
ELECTROCHIMICA ACTA, 2008, 53 (10) :3635-3642
[8]   Novel electrochemical sensor based on N-doped carbon nanotubes and Fe3O4 nanoparticles: Simultaneous voltammetric determination of ascorbic acid, dopamine and uric acid [J].
Fernandes, Diana M. ;
Costa, Marta ;
Pereira, Clara ;
Bachiller-Baeza, Belen ;
Rodriguez-Ramos, Inmaculada ;
Guerrero-Ruiz, Antonio ;
Freire, Cristina .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2014, 432 :207-213
[9]   An amperometric glucose biosensor based on layer-by-layer GOx-SWCNT conjugate/redox polymer multilayer on a screen-printed carbon electrode [J].
Gao, Qiang ;
Guo, Yanyan ;
Zhang, Wenyan ;
Qi, Honglan ;
Zhang, Chengxiao .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 153 (01) :219-225
[10]   Simultaneous determination of maltose and glucose using a screen-printed electrode system [J].
Ge, F ;
Zhang, XE ;
Zhang, ZP ;
Zhang, XM .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (3-4) :333-339