Analytical developments in secondary ion mass spectrometry 2003

被引:3
作者
Deloule, E
Wiedenbeck, M
机构
[1] CNRS, CRPG, F-54501 Vandoeuvre Les Nancy, France
[2] Geoforschungszentrum Potsdam, D-14473 Potsdam, Germany
关键词
review; secondary ion mass spectrometry; geochronology; U-Pb; zircon; reference samples; NanoSIMS; time-of-flight SIMS;
D O I
10.1111/j.1751-908X.2005.tb00653.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
This annual review of secondary ion mass spectrometry (SIMS) highlights significant progress in the application of the technology for the following areas: U-Pb geochronology (notably in the fields of reference material zircons), sources of uncertainty during analysis and secondary ion yields. Major publications introduced a new zircon reference sample and dealt with an intercomparison study of a suite of established calibrators, some of which have been shown to have certain limitations. Another publication claimed that the principal uncertainty in U-Pb dating is related to variations in the Pb and U relative emission yields over a complete analytical session. 2003 saw the introduction of an automated particle identification procedure applied to the analysis of a chondritic meteorite, as well as new geometries of SIMS hardware (NanoSIMS) and techniques (time-of-flight SIMS). NanoSIMS allows a two to three order of magnitude reduction in sampling volume as a result of a reduced beam diameter, and time-of-flight SIMS allows the study of sample surfaces, and can provide data for elements concurrently.
引用
收藏
页码:37 / 40
页数:4
相关论文
共 50 条
[31]   Isotope ratio measurements by secondary ion mass spectrometry (SIMS) and glow discharge mass spectrometry (GDMS) [J].
Betti, M .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) :169-182
[32]   Assessment of crystallographic orientation effects on secondary ion mass spectrometry (SIMS) analysis of cassiterite [J].
Carr, Patrick A. ;
Norman, Marc D. ;
Bennett, Vickie C. .
CHEMICAL GEOLOGY, 2017, 467 :122-133
[33]   Capillary electrophoresis-mass spectrometry: Survey on developments and applications 2003-2004 [J].
Schmitt-Kopplin, P ;
Englmann, M .
ELECTROPHORESIS, 2005, 26 (7-8) :1209-1220
[34]   Nano-scale secondary ion mass spectrometry - A new analytical tool in biogeochemistry and soil ecology: A review article [J].
Herrmann, Anke M. ;
Ritz, Karl ;
Nunan, Naoise ;
Clode, Peta L. ;
Pett-Ridge, Jennifer ;
Kilburn, Matt R. ;
Murphy, Daniel V. ;
O'Donnell, Anthony G. ;
Stockdale, Elizabeth A. .
SOIL BIOLOGY & BIOCHEMISTRY, 2007, 39 (08) :1835-1850
[35]   Resonance-enhanced multiphoton ionization/secondary neutral mass spectrometry and cesium attachment secondary ion mass spectrometry of bronze: a comparison [J].
McCann, MP ;
Calaway, WF ;
Pellin, MJ ;
Veryovkin, IV ;
Constantinides, I ;
Adriaens, A ;
Adams, F .
SURFACE AND INTERFACE ANALYSIS, 2002, 33 (05) :394-400
[36]   GGR critical review of analytical developments in 2003 [J].
Hergt, JM ;
Bédard, LP ;
Deloule, E ;
Linge, KL ;
Sylvester, PJ ;
Wiedenbeck, M ;
Woodhead, JD .
GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2005, 29 (01) :5-6
[37]   In situ imaging of lithium-ion batteries via the secondary ion mass spectrometry [J].
ChiuHuang, Cheng-Kai ;
Zhou, Chuanzhen ;
Shadow Huang, Hsiao-Ying .
Journal of Nanotechnology in Engineering and Medicine, 2014, 5 (02)
[38]   Microanalysis by focused ion beam secondary ion mass spectrometry (FIB-SIMS) [J].
Nihei, Y ;
Tomiyasu, B ;
Sakamoto, T ;
Owari, M .
JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 1997, 15 (04) :593-599
[39]   Visualization of metallodrugs in single cells by secondary ion mass spectrometry imaging [J].
Kui Wu ;
Feifei Jia ;
Wei Zheng ;
Qun Luo ;
Yao Zhao ;
Fuyi Wang .
JBIC Journal of Biological Inorganic Chemistry, 2017, 22 :653-661
[40]   Quantification of Hydrogen in Natural Diamond by Secondary Ion Mass Spectrometry (SIMS) [J].
Kaminsky, F. V. ;
Shilobreeva, S. N. ;
Ber, B. Ya. ;
Kazantsev, D. Yu. .
DOKLADY EARTH SCIENCES, 2020, 494 (01) :699-703