Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study

被引:41
|
作者
Giantsoudi, Drosoula [1 ,2 ]
Schuemann, Jan [1 ,2 ]
Jia, Xun [3 ]
Dowdell, Stephen [4 ]
Jiang, Steve [3 ]
Paganetti, Harald [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Univ Texas SW Med Ctr Dallas, Dept Radiat Oncol, Dallas, TX 75390 USA
[4] Shoalhaven Canc Care Ctr, Nowra, NSW, Australia
关键词
Monte Carlo; GPU; gPMC; clinical validation; proton radiation therapy; RANGE UNCERTAINTIES; DOSE CALCULATION; ELECTRON-TRANSPORT; DISTRIBUTIONS; SIMULATION; ALGORITHM; GEANT4; TOPAS;
D O I
10.1088/0031-9155/60/6/2257
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Monte Carlo (MC) methods are recognized as the gold-standard for dose calculation, however they have not replaced analytical methods up to now due to their lengthy calculation times. GPU-based applications allow MC dose calculations to be performed on time scales comparable to conventional analytical algorithms. This study focuses on validating our GPU-based MC code for proton dose calculation (gPMC) using an experimentally validated multi-purpose MC code (TOPAS) and compare their performance for clinical patient cases. Clinical cases from five treatment sites were selected covering the full range from very homogeneous patient geometries (liver) to patients with high geometrical complexity (air cavities and density heterogeneities in head-and-neck and lung patients) and from short beam range (breast) to large beam range (prostate). Both gPMC and TOPAS were used to calculate 3D dose distributions for all patients. Comparisons were performed based on target coverage indices (mean dose, V-95, D-98, D-50, D-02) and gamma index distributions. Dosimetric indices differed less than 2% between TOPAS and gPMC dose distributions for most cases. Gamma index analysis with 1%/1 mm criterion resulted in a passing rate of more than 94% of all patient voxels receiving more than 10% of the mean target dose, for all patients except for prostate cases. Although clinically insignificant, gPMC resulted in systematic underestimation of target dose for prostate cases by 1-2% compared to TOPAS. Correspondingly the gamma index analysis with 1%/1 mm criterion failed for most beams for this site, while for 2%/1 mm criterion passing rates of more than 94.6% of all patient voxels were observed. For the same initial number of simulated particles, calculation time for a single beam for a typical head and neck patient plan decreased from 4 CPU hours per million particles (2.8-2.9 GHz Intel X5600) for TOPAS to 2.4 s per million particles (NVIDIA TESLA C2075) for gPMC. Excellent agreement was demonstrated between our fast GPU-based MC code (gPMC) and a previously extensively validated multi-purpose MC code (TOPAS) for a comprehensive set of clinical patient cases. This shows that MC dose calculations in proton therapy can be performed on time scales comparable to analytical algorithms with accuracy comparable to state-of-the-art CPU-based MC codes.
引用
收藏
页码:2257 / 2269
页数:13
相关论文
共 50 条
  • [21] Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved 177Lu images
    Ryden, T.
    Lagerlof, J. Heydorn
    Hemmingsson, J.
    Marin, I.
    Svensson, J.
    Bath, M.
    Gjertsson, P.
    Bernhardt, P.
    EJNMMI PHYSICS, 2018, 5
  • [22] A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy
    Kalantzis, Georgios
    Leventouri, Theodora
    Tachibana, Hidenobu
    Shang, Charles
    SOFTWARE ENGINEERING, ARTIFICIAL INTELLIGENCE, NETWORKING AND PARALLEL/DISTRIBUTED COMPUTING 2015, 2016, 612 : 17 - 29
  • [23] Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport
    Jia, Xun
    Gu, Xuejun
    Sempau, Josep
    Choi, Dongju
    Majumdar, Amitava
    Jiang, Steve B.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11) : 3077 - 3086
  • [24] Fast Monte-Carlo Photon Transport Employing GPU-Based Parallel Computation
    Mirzapour, M.
    Hadad, K.
    Faghihi, R.
    Hamilton, R. J.
    Watchman, C. J.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2020, 4 (04) : 450 - 460
  • [25] gMCAP: a GPU-based Monte Carlo proton transport program for high-density tissues with precise nuclear reaction models
    Luo, Xi-Yu
    Sun, Liang
    Wu, Zhen
    Qiu, Rui
    Xu, Shou-Ping
    Zhang, Hui
    Li, Jun-Li
    NUCLEAR SCIENCE AND TECHNIQUES, 2025, 36 (05)
  • [26] q-state Potts model metastability study using optimized GPU-based Monte Carlo algorithms
    Ferrero, Ezequiel E.
    Pablo De Francesco, Juan
    Wolovick, Nicolas
    Cannas, Sergio A.
    COMPUTER PHYSICS COMMUNICATIONS, 2012, 183 (08) : 1578 - 1587
  • [27] A study of potential numerical pitfalls in GPU-based Monte Carlo dose calculation
    Magnoux, Vincent
    Ozell, Benoit
    Bonenfant, Eric
    Despres, Philippe
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (13) : 5007 - 5018
  • [28] Fast GPU-based Monte Carlo code for SPECT/CT reconstructions generates improved 177Lu images
    T. Rydén
    J. Heydorn Lagerlöf
    J. Hemmingsson
    I. Marin
    J. Svensson
    M. Båth
    P. Gjertsson
    P. Bernhardt
    EJNMMI Physics, 5
  • [29] A dynamic accuracy estimation for GPU-based monte carlo simulation in tissue optics
    Cai F.
    Lu W.
    Lu, Wen (wen_lu@yeah.net), 2017, Optical Society of Korea (01) : 551 - 555
  • [30] A GPU-based pencil beam algorithm for dose calculations in proton radiation therapy
    Kalantzis G.
    Leventouri T.
    Tachibana H.
    Shang C.
    International Journal of Networked and Distributed Computing, 2015, 3 (4) : 243 - 249