Indoor Air Quality and Sick Building Syndrome Among Nigerian Laboratory University Workers

被引:2
作者
Reuben, Usaku [1 ,3 ]
Ismail, Ahmad F. [1 ]
Ahmad, Abdul Latif [2 ]
Maina, Humphrey M. [3 ]
Daud, Aziah [1 ]
机构
[1] Univ Sains Malaysia, Sch Med Sci, Dept Community Med, Kubang Kerian 16150, Kelantan, Malaysia
[2] Univ Sains Malaysia, Sch Chem Engn, Engn Campus, Nibong Tebal 14300, Pulau Pinang, Malaysia
[3] Modibbo Adama Univ Technol, Sch Pure & Appl Sci, Dept Chem, PMB 2076, Yola, Adamawa State, Nigeria
关键词
Sick building syndrome; dosimeter tubes; air quality control meter; indoor air quality; workplace health; VENTILATION RATE; SYMPTOMS; TEMPERATURE; POLLUTION; HUMIDITY;
D O I
10.21315/jps2019.30.1.13
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Indoor air quality refers to the air quality in and around laboratory buildings and facilities, which directly affects the health and comfort of workers. Poor air quality poses numerous health challenges to the laboratory workers and environment, and causes sick building syndrome (SBS) among workers. The objective of this study is to determine associations of SBS related to indoor air concentration in a dose-dependent manner among Nigerian laboratory university workers. This was a cross-sectional study on a population-based sample of Nigerian university laboratories and the workers. Data were collected using an indoor air quality control meter, dosimeter tubes gases of interest, and a set of questionnaires (MM-40). The results showed that the mean indoor air concentrations in a dose-dependent manner for chemical parameters range from 473.0 ppm to753.0 ppm, 17.9 ppm to 27.3 ppm, 5.7 ppm to 8.5 ppm, and 6.3 ppm to 9.1 ppm for CO2, CO, NO2, H2S and SO2, respectively. The prevalence of SBS, i.e., skin-related syndrome (SRS) is 38.5%, general-related symptom (GRS) is 28.3%, mucosal-related symptom (MRS) is 19.2% and at least one score was a respiratory-related symptom (RRS), which is 13.9%. The significant associated factors of SBS revealed by multinomial logistic regression in this study were NO2 [SRS (P = 0.022), GRS (P = 0.023), MRS (P = 0.032)], H2S [SRS (P = 0.031), GRS (P < 0.001), MRS (P = 0.021)], and SO2 [SRS (P = 0.001), GRS (P < 0.001), MRS (P = 0.022)]. On the other hand, office laboratory temperature and relative humidity were shown to be negatively statistically associated with prevalence symptoms relative to RRS. In this study, SBS was found to be high. Indoor air concentration in a dose-dependent manner and environmental parameters could increase the prevalence and incidence of SBS-related symptoms. Therefore, it is important to educate the workers on occupational and environmental health at a workplace to minimise SBS in the future.
引用
收藏
页码:179 / 195
页数:17
相关论文
共 25 条
  • [1] [Anonymous], 2016, GLOB J HLTH SCI
  • [2] Bruce N, 2000, B WORLD HEALTH ORGAN, V78, P1078
  • [3] Prevalence of Sick Building Syndrome-Related Symptoms among Hospital Workers in Confined and Open Working Spaces
    Chang, Chia-Jen
    Yang, Hsi-Hsien
    Wang, Ya-Fen
    Li, Min-Shan
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2015, 15 (06) : 2378 - 2384
  • [4] Chirico F., 2017, Journal of Health and Social Sciences, V2, P31, DOI [10.19204/2017/prvl3, DOI 10.19204/2017/PRVL3]
  • [5] Impact of indoor air temperature and humidity in an office on perceived air quality, SBS symptoms and performance
    Fang, L
    Wyon, DP
    Clausen, G
    Fanger, PO
    [J]. INDOOR AIR, 2004, 14 : 74 - 81
  • [6] Survey of air pollution in Cotonou, Benin - air monitoring and biomarkers
    Fanou, LA
    Mobio, TA
    Creppy, EE
    Fayomi, B
    Fustoni, S
    Moller, P
    Kyrtopoulos, S
    Georgiades, P
    Loft, S
    Sanni, A
    Skov, H
    Ovrebo, S
    Autrup, H
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2006, 358 (1-3) : 85 - 96
  • [7] The Declaration of Helsinki
    Goodyear, Michael D. E.
    Krleza-Jeric, Karmela
    Lernmens, Trudo
    [J]. BRITISH MEDICAL JOURNAL, 2007, 335 (7621): : 624 - 625
  • [8] Limitations of Carbon Footprint as Indicator of Environmental Sustainability
    Laurent, Alexis
    Olsen, Stig I.
    Hauschild, Michael Z.
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2012, 46 (07) : 4100 - 4108
  • [9] Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making
    Maddalena, R.
    Mendell, M. J.
    Eliseeva, K.
    Chan, W. R.
    Sullivan, D. P.
    Russell, M.
    Satish, U.
    Fisk, W. J.
    [J]. INDOOR AIR, 2015, 25 (04) : 362 - 370
  • [10] Indoor air quality in Portuguese schools: levels and sources of pollutants
    Madureira, J.
    Paciencia, I.
    Pereira, C.
    Teixeira, J. P.
    Fernandes, E. de O.
    [J]. INDOOR AIR, 2016, 26 (04) : 526 - 537