摘要
Based on the conventional high-strength bolt connection, a new occlusive high-strength bolt (OHSB) connection was developed. In this paper, tests on eighteen connections including four conventional high-strength bolt connections and fourteen OHSB connections were carried out. The main failure mode of these conventional high strength bolt connections was the shear rupture of bolts, while the main failure mode of these OHSB connections was the dislocation of plates and the loose of bolts. It is found that the load-bearing capacity of OHSB connections was improved significantly. Moreover, both the bolt pretension and the groove size had an important effect on the bearing behavior of OHSB connections. Finite element (FE) models implemented in the non-linear code ABAQUS were established and were verified against the experimental results. It is indicated that the FE models can be used effectively to describe the mechanical performance of OHSB connections, including the failure modes and load-displacement curves. To develop a further understanding, parametric analyses which consider the influence of the bolt pretension and the groove size on the load-bearing capacity of OHSB connections were performed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 22 条
[1]   Slip resistance of metalized-galvanized faying surfaces in steel bridge construction [J].
Annan, Charles-Darwin ;
Chiza, Albert .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 95 :211-219
[2]   Characterization of slip resistance of high strength bolted connections with zinc-based metallized faying surfaces [J].
Annan, Charles-Darwin ;
Chiza, Albert .
ENGINEERING STRUCTURES, 2013, 56 :2187-2196
[3]  
[Anonymous], 2010, 2282010 GBT
[4]  
[Anonymous], Abaqus analysis user's manual
[5]   Experimental study of semi-rigid joint systems subjected to bending with and without axial force [J].
Fan, Feng ;
Ma, Huihuan ;
Chen, Gengbo ;
Shen, Shizhao .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2012, 68 (01) :126-137
[6]   Tests of concrete-filled stainless steel tubular T-joints [J].
Feng, Ran ;
Young, Ben .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (11) :1283-1293
[7]   Design of cold-formed stainless steel tubular T- and X-joints [J].
Feng, Ran ;
Young, Ben .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2011, 67 (03) :421-436
[8]   Behaviour of concrete-filled stainless steel tubular X-Joints subjected to compression [J].
Feng, Ran ;
Young, Ben .
THIN-WALLED STRUCTURES, 2009, 47 (04) :365-374
[9]   Experimental studies on behaviour of bolted ball-cylinder joints under axial force [J].
Guo, Xiaonong ;
Huang, Zewei ;
Xiong, Zhe ;
Yang, Shangfei ;
Peng, Li .
STEEL AND COMPOSITE STRUCTURES, 2016, 21 (01) :137-156
[10]   Numerical studies on behaviour of bolted ball-cylinder joint under axial force [J].
Guo, Xiaonong ;
Huang, Zewei ;
Xiong, Zhe ;
Yang, Shangfei ;
Peng, Li .
STEEL AND COMPOSITE STRUCTURES, 2016, 20 (06) :1323-1343