Functional MR Imaging on an Open 1T MR Imaging System: Exploiting the Advantages of an Open MR Imaging System for Functional MR Imaging

被引:1
作者
van de Giessen, E. [1 ]
Groot, P. F. C. [2 ]
Booij, J. [1 ]
van den Brink, W. [3 ]
Veltman, D. J. [3 ]
Nederveen, A. J. [2 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Dept Nucl Med, NL-1105 AZ Amsterdam, Netherlands
[2] Univ Amsterdam, Acad Med Ctr, Dept Radiol, NL-1105 AZ Amsterdam, Netherlands
[3] Univ Amsterdam, Acad Med Ctr, Amsterdam Inst Addict Res, NL-1105 AZ Amsterdam, Netherlands
关键词
BOLD CONTRAST; MOTOR TASK; 1.0; T; FMRI; CORTEX; ECHO; EPI; VARIABILITY; DEPENDENCE; ACTIVATION;
D O I
10.3174/ajnr.A2383
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Open MR imaging scanners are designed for imaging of specific patient groups that cannot be routinely scanned with conventional MR imaging scanners (eg, patients with obesity and claustrophobia). This study aims to determine whether BOLD sensitivity on an open 1T scanner is adequate for fMRI for diagnostic and research purposes by directly comparing fMRI results with a standard 3T MR imaging scanner The optimal TE was also determined. MATERIALS AND METHODS: Twelve healthy adults were scanned by using both an open 1T scanner and a standard 3T scanner. Gradient-echo echo-planar images were acquired for all subjects while performing motor and affective paradigms, each at 5 different TEs per scanner (range, 40-80 ms at open 1T; 20-40 ms at 3T). To compare BOLD sensitivity between scanners and TEs, we determined maximum statistical t scores per TE for all relevant brain areas (motor cortex, visual cortex, amygdala, and OFC) for individual subjects and group analyses. Additionally, T2* values were determined per scanner for the relevant brain areas. RESULTS: Maximum t scores were significantly lower in the relevant brain areas on the open 1T compared with the 3T for single subjects but not for group analyses. The optimal TE for fMRI on an open 1T MR imaging system was found to be approximately 70 ms. CONCLUSIONS: Although for single-subject studies as used in diagnostics, 31 was found to be superior, fMRI on an open 1T MR imaging scanner is suitable for research designed to analyze data at a group level.
引用
收藏
页码:903 / 907
页数:5
相关论文
共 16 条
  • [1] SPIN-ECHO AND GRADIENT-ECHO EPI OF HUMAN BRAIN ACTIVATION USING BOLD CONTRAST - A COMPARATIVE-STUDY AT 1.5 T
    BANDETTINI, PA
    WONG, EC
    JESMANOWICZ, A
    HINKS, RS
    HYDE, JS
    [J]. NMR IN BIOMEDICINE, 1994, 7 (1-2) : 12 - 20
  • [2] Functional MR study of a motor task and the Tower of London task at 1.0 T
    Boghi, A.
    Rampado, O.
    Bergui, M.
    Avidano, F.
    Manzone, C.
    Coriasco, M.
    Mortara, P.
    Orsi, L.
    Ropolo, R.
    Bradac, G. B.
    [J]. NEURORADIOLOGY, 2006, 48 (10) : 763 - 771
  • [3] EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidth
    Fera, F
    Yongbi, MN
    van Gelderen, P
    Frank, JA
    Mattay, VS
    Duyn, JH
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (01) : 19 - 26
  • [4] Experimental determination of the BOLD field strength dependence in vessels and tissue
    Gati, JS
    Menon, RS
    Ugurbil, K
    Rutt, BK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (02) : 296 - 302
  • [5] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING OF PRIMARY VISUAL PROCESSING USING A 1.0 TESLA SCANNER
    LUNDERVOLD, A
    ERSLAND, L
    GJESDAL, KI
    SMIEVOLL, AI
    TILLUNG, T
    SUNDBERG, H
    HUGDAHL, K
    [J]. INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1995, 81 (3-4) : 151 - 168
  • [6] Variability in fMRI: An examination of intersession differences
    McGonigle, DJ
    Howseman, AM
    Athwal, BS
    Friston, KJ
    Frackowiak, RSJ
    Holmes, AP
    [J]. NEUROIMAGE, 2000, 11 (06) : 708 - 734
  • [7] Functional BOLD MRI: comparison of different field strengths in a motor task
    Meindl, T.
    Born, C.
    Britsch, S.
    Reiser, M.
    Schoenberg, S.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (06) : 1102 - 1113
  • [8] Magnetic field strength increase yields significantly greater contrast-to-noise ratio increase: Measured using BOLD contrast in the primary visual area
    Okada, T
    Yamada, H
    Ito, H
    Yonekura, Y
    Sadato, N
    [J]. ACADEMIC RADIOLOGY, 2005, 12 (02) : 142 - 147
  • [9] Clinical applications of functional MRI at 1.0 T: motor and language studies in healthy subjects and patients
    Papke, K
    Hellmann, T
    Renger, B
    Morgenroth, C
    Knecht, S
    Schuierer, G
    Reimer, P
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (02) : 211 - 220
  • [10] Variability in fMRI: A re-examination of inter-session differences
    Smith, SM
    Beckmann, CF
    Ramnani, N
    Woolrich, MW
    Bannister, PR
    Jenkinson, M
    Matthews, PM
    McGonigle, DJ
    [J]. HUMAN BRAIN MAPPING, 2005, 24 (03) : 248 - 257