Acute and mid-term results of phosphorylcholine-coated stents in primary coronary stenting for acute myocardial infarction

被引:30
作者
Galli, M
Sommariva, L
Prati, F
Zerboni, S
Politi, A
Bonatti, R
Mameli, S
Butti, E
Pagano, A
Ferrari, G
机构
[1] St Anna Hosp, Catheterizat Lab, Dept Cardiol, I-22100 Como, Italy
[2] European Hosp, European Imaging Core Lab, Rome, Italy
关键词
clinical experience; coated coronary stent; acute myocardial infarction;
D O I
10.1002/ccd.1145
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this pilot study was to evaluate the safety and efficacy of the BiodivYsio phosphorylcholine-coated stent in the primary treatment of acute myocardial infarction. The BiodivYsio stent (Biocompatible) is a balloon-expandable stent, laser etched from a 316 L stainless steel tube. This device is coated with phosphorylcholine, a synthetic, hemocompatible phospholipid polymer that has been shown in experimental studies to reduce platelet and protein adhesion to the surface of the metal. One hundred consecutive patients within 24 hr of symptoms of onset of acute MI, treated with primary PICA, were enrolled. After PICA, stenting was attempted in all eligible lesions (reference diameter greater than or equal to 2.5 mm; no bend lesion > 45 degrees). Poststenting regimens contained ticlopidine (500 mg/day) and aspirin (325 mg/day) and 6-12 hr of heparin infusion. Procedural success (TIMI greater than or equal to II and residual stenosis < 30%) was obtained in 70/74 cases (95%). TIMI grade III was restored in 90% of cases. In the patient group with procedural success (70 cases), 70 BiodivYsio stents were placed. After stenting, diameter stenosis decreased from 96% +/- 11% to 22% +/- 12% (P < 0.01) and minimal luminal diameter increased from 0.13 +/- 0.29 to 2.47 +/- 0.43 (P < 0.01). Nominal stent diameter was between 3.0 and 4.0 mm (mean, 3.5 +/- 0.4 mm). Stent length was between 11 and 28 mm (mean, 17 +/- 4.5 mm). Clinical follow-up was obtained in all patients; angiographic follow-up was performed in 65/70 (93%). No acute or subacute thrombosis was reported. Two in-hospital major adverse cardiac events (MACE) were reported due to a nontreated left main disease that required coronary artery bypass graft (CABG) surgery. At follow-up, MACE were found in 9 of 68 patients (13%), target lesion revascularization (TLR) in 6%, and CABG in the remaining 6%. Primary stenting with phosphorylcholine-coated stent leads to excellent short- and mid-term clinical outcomes and is associated with a restenosis rate of 12%. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:182 / 187
页数:6
相关论文
共 26 条
[1]   CORONARY STENTING FOR ACUTE MYOCARDIAL-INFARCTION [J].
AHMAD, T ;
WEBB, JG ;
CARERE, RR ;
DODEK, A .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (01) :77-80
[2]   A clinical trial comparing primary stenting of the infarct-related artery with optimal primary angioplasty for acute myocardial infarction - Results from the Florence Randomized Elective Stenting in Acute Coronary Occlusions (FRESCO) trial [J].
Antoniucci, D ;
Santoro, GM ;
Bolognese, L ;
Valenti, R ;
Trapani, M ;
Fazzini, PF .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1234-1239
[3]  
BAILEY SR, 1992, CIRCULATION, V86, P186
[4]   FAILED DIRECT CORONARY ANGIOPLASTY FOR ACUTE MYOCARDIAL-INFARCTION - IN-HOSPITAL OUTCOME AND PREDICTORS OF DEATH [J].
BEDOTTO, JB ;
KAHN, JK ;
RUTHERFORD, BD ;
MCCONAHAY, DR ;
GIORGI, LV ;
JOHNSON, WL ;
OKEEFE, JH ;
SHIMSHAK, TM ;
LIGON, RW ;
HARTZLER, GO .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (03) :690-694
[5]  
CRONOS NAF, 1995, AM HEART ASS S, V92, P685
[6]   A comparison of thrombolytic therapy with primary coronary angioplasty for acute myocardial infarction [J].
Every, NR ;
Parsons, LS ;
Hlatky, M ;
Martin, JS ;
Weaver, WD .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (17) :1253-1260
[7]   Stent implantation in acute myocardial infarction [J].
GarciaCantu, E ;
Spaulding, C ;
Corcos, T ;
BenHamda, K ;
Roussel, L ;
Favereau, X ;
Guerin, Y ;
Chalet, Y ;
Souffrant, G ;
Guerin, F .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 77 (07) :451-454
[8]  
Grines C. L., 1997, Journal of the American College of Cardiology, V29, p389A
[9]   Coronary angioplasty with or without stent implantation for acute myocardial infarction [J].
Grines, CL ;
Cox, DA ;
Stone, GW ;
Garcia, E ;
Mattos, LA ;
Giambartolomei, A ;
Brodie, BR ;
Madonna, O ;
Eijgelshoven, M ;
Lansky, AJ ;
O'Neill, WW ;
Morice, MC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (26) :1949-1956
[10]   A COMPARISON OF IMMEDIATE ANGIOPLASTY WITH THROMBOLYTIC THERAPY FOR ACUTE MYOCARDIAL-INFARCTION [J].
GRINES, CL ;
BROWNE, KF ;
MARCO, J ;
ROTHBAUM, D ;
STONE, GW ;
OKEEFE, J ;
OVERLIE, P ;
DONOHUE, B ;
CHELLIAH, N ;
TIMMIS, GC ;
VLIETSTRA, RE ;
STRZELECKI, M ;
PUCHROWICZOCHOCKI, S ;
ONEILL, WW .
NEW ENGLAND JOURNAL OF MEDICINE, 1993, 328 (10) :673-679