A method for T1 and T2 relaxation times validation and harmonization as a support to MRI mapping

被引:3
作者
Cicolari, Davide [1 ,2 ]
Lizio, Domenico [3 ]
Pedrotti, Patrizia [4 ]
Moioli, Monica Teresa [3 ]
Lascialfari, Alessandro [1 ,2 ]
Mariani, Manuel [1 ,2 ]
Torresin, Alberto [3 ,5 ]
机构
[1] Univ Pavia, Dept Phys, Via Bassi 6, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Pavia Unit, Via Bassi 6, I-27100 Pavia, Italy
[3] ASST Grande Osped Metropolitano Niguarda, Dept Med Phys, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[4] ASST Grande Osped Metropolitano Niguarda, Dept Cardiol, Pzza Osped Maggiore 3, I-20162 Milan, Italy
[5] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
关键词
Relaxation time maps; Data harmonization; Calibration; Accuracy; Precision; INVERSION-RECOVERY MOLLI; HIGH-RESOLUTION T-1; PARAMAGNETIC SOLUTIONS; HUMAN MYOCARDIUM; T1; ACCURACY; REPRODUCIBILITY; PRECISION; CALIBRATION; SEQUENCES;
D O I
10.1016/j.jmr.2021.107110
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a proof-of-concept study focusing on a method for the intra- and inter-center validation and harmonization of data obtained from MRI T-1 and T-2 maps. The method is based on a set of MnCl2 samples that provide in-scan ground-truth reference values regardless of the details of the MRI protocol. The relaxation times of MnCl2 aqueous solutions were first measured by means of an NMR laboratory relaxometer, as a function of concentration and temperature. The obtained T-1 and T-2 values, once renormalized at the scanner temperature, were used as reference values for the MRI mapping measurements of the MnCl2 relaxation times. By using different clinical MRI scanners and sequences, we found a good agreement for standard and turbo sequences (limits of agreement: 5% for IR, SE, IR-TSE; 10% for TSE), while an under-estimation and an over-estimation were found respectively for MOLLI and T-2-prep TrueFISP, as already reported in the literature. The linearity of the relaxation rates with the concentration predicted by the Solomon-Bloembergen-Morgan theory was observed for every dataset at all temperatures, except for T-2-prep TrueFISP maps results. Some preliminary results of an in vivo experiment are also presented. (C) 2021 Elsevier Inc. All rights reserved.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Nonrigid active shape model-based registration framework for motion correction of cardiac T1 mapping
    El-Rewaidy, Hossam
    Nezafat, Maryam
    Jang, Jihye
    Nakamori, Shiro
    Fahmy, Ahmed S.
    Nezafat, Reza
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 780 - 791
  • [42] Age and sex corrected normal reference values of T1, T2 T2*and ECV in healthy subjects at 3T CMR
    Roy, Clotilde
    Slimani, Alisson
    de Meester, Christophe
    Amzulescu, Mihaela
    Pasquet, Agnes
    Vancraeynest, David
    Vanoverschelde, Jean-Louis
    Pouleur, Anne-Catherine
    Gerber, Bernhard L.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [43] Diagnosis of Acute GLobal. Myocarditis Using Cardiac MRI with Quantitative T1 and T2 Mapping: Case Report and Literature Review
    Park, Chul Hwan
    Choi, Eui-Young
    Greiser, Andreas
    Paek, Mun Young
    Hwang, Sung Ho
    Kim, Tae Hoon
    KOREAN JOURNAL OF RADIOLOGY, 2013, 14 (05) : 727 - 732
  • [44] Image resampling and discretization effect on the estimate of myocardial radiomic features from T1 and T2 mapping in hypertrophic cardiomyopathy
    Marfisi, Daniela
    Tessa, Carlo
    Marzi, Chiara
    Del Meglio, Jacopo
    Linsalata, Stefania
    Borgheresi, Rita
    Lilli, Alessio
    Lazzarini, Riccardo
    Salvatori, Luca
    Vignali, Claudio
    Barucci, Andrea
    Mascalchi, Mario
    Casolo, Giancarlo
    Diciotti, Stefano
    Traino, Antonio Claudio
    Giannelli, Marco
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [45] Comparison of myocardial T1 and T2 values in 3 T with T2*in 1.5 T in patients with iron overload and controls
    Camargo, Gabriel C.
    Rothstein, Tamara
    Junqueira, Flavia P.
    Fernandes, Elsa
    Greiser, Andreas
    Strecker, Ralph
    Pessoa, Viviani
    Lima, Ronaldo S. L.
    Gottlieb, Ilan
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2016, 103 (05) : 530 - 536
  • [46] Single breath-hold MR T1 mapping in the heart: Hybrid MOLLI combining saturation and inversion recovery
    Yu, Chun -Yang
    Huang, Teng-Yi
    Chung, Hsiao-Wen
    MAGNETIC RESONANCE IMAGING, 2023, 96 : 85 - 92
  • [47] On the accuracy and precision of cardiac magnetic resonance T2 mapping: A high-resolution radial study using adiabatic T2 preparation at 3T
    Bano, Wajiha
    Feliciano, Helene
    Coristine, Andrew J.
    Stuber, Matthias
    van Heeswijk, Ruud B.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 159 - 169
  • [48] Inter-scanner comparability of Z-scores for native myocardial T1 and T2 mapping
    Razzaq, Saad
    Haririsanati, Leila
    Eyre, Katerina
    Garg, Ria
    Chetrit, Michael
    Friedrich, Matthias G.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (01)
  • [49] Three-dimensional T1, T2 and proton density mapping with inversion recovery balanced SSFP
    Newbould, Rexford D.
    Skare, Stefan T.
    Alley, Marcus T.
    Gold, Garry E.
    Bammer, Roland
    MAGNETIC RESONANCE IMAGING, 2010, 28 (09) : 1374 - 1382
  • [50] Cardiac MRI and Texture Analysis of Myocardial T1 and T2 Maps in Myocarditis with Acute versus Chronic Symptoms of Heart Failure
    Baessler, Bettina
    Luecke, Christian
    Lurz, Julia
    Klingel, Karin
    Das, Arijit
    von Roeder, Maximilian
    de Waha-Thiele, Suzanne
    Besler, Christian
    Rommel, Karl-Philipp
    Maintz, David
    Gutberlet, Matthias
    Thiele, Hoker
    Lurz, Philipp
    RADIOLOGY, 2019, 292 (03) : 608 - 617